Carrier 40RFAA12 Installation, Start-Up And Service Instructions Manual

Carrier 40RFAA12 Installation, Start-Up And Service Instructions Manual

Packaged air-handling units with puron® (r-410a) refrigerant 60 hz

Advertisement

CONTENTS
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
PRE-INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Moving and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rigging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Uncrating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rated Indoor Airflow (cfm) . . . . . . . . . . . . . . . . . . . . . 9
Unit Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Unit Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Refrigerant Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Chilled Water Piping . . . . . . . . . . . . . . . . . . . . . . . . . 12
Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Fan Motors and Drives . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Power Supply and Wiring . . . . . . . . . . . . . . . . . . . . . . . 13
Connecting Ductwork . . . . . . . . . . . . . . . . . . . . . . . . 18
Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
40RFA and 40RFQ ONLY . . . . . . . . . . . . . . . . . . . . . 19
(40RFA and 40RFQ only) . . . . . . . . . . . . . . . . . . . 19
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
SUPPLY FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Supply Fan (Direct-Drive) . . . . . . . . . . . . . . . . . . . . . 20
Condensate Drains . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Chilled Water Coil Freeze Protection . . . . . . . . . . . 26
Coil Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Cleaning Cooling Coil . . . . . . . . . . . . . . . . . . . . . . . . 26
Cleaning Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53400080-01
Installation, Start-up and
Service Instructions
Printed in U.S.A.
Form 40RF-7-12-02SI Rev. A
Packaged Air-Handling Units
with Puron
Replacing Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Page
(and 30 days after initial start) . . . . . . . . . . . . . . .27
Seasonal Maintenance . . . . . . . . . . . . . . . . . . . . . . .27
FAN PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . .28
START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . .CL-1

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components. Only
trained and qualified service personnel should install, repair, or
service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of
cleaning coils and filters and replacing filters. All other operations
should be performed by trained service personnel. When working
on air-conditioning equipment, observe precautions in the
literature, tags and labels attached to the unit, and other safety
precautions that may apply.
Follow all safety codes, including ANSI (American National
Standards Institute) Z223.1. Wear safety glasses and work gloves.
Use quenching cloth for unbrazing operations. Have fire
extinguisher available for all brazing operations.
It is important to recognize safety information. This is the safety-
alert symbol
instructions or manuals, be alert to the potential for personal
injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury or death. CAUTION is used
to identify unsafe practices, which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning will result in personal injury or
death.
Before performing service or maintenance operations on unit,
turn off main power switch to unit and install lock(s) and
lockout tag(s). Ensure electrical service to rooftop unit agrees
with voltage and amperage listed on the unit rating plate. Unit
may have more than one power switch.
Pg 1
40RF/A/S/Q 07-12
®
(R-410A) Refrigerant
. When you see this symbol on the unit and in
DANGER
2-23
Replaces: 40RU-7-16-01SI
60 Hz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40RFAA12 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Pre-Installation
Moving and Storage
Procedures for handling the unit during transit and storage.
Rigging
Guidelines for lifting and moving the unit using rigging equipment.
Installation
General
Specifies required clearances for service access and airflow.
Uncrating
Instructions for safely removing the unit from its shipping container.
Accessories
Refers to installation instructions for optional unit accessories.
Unit Positioning
How to mount the unit for vertical or horizontal application.
Unit Isolation
Methods for reducing vibration and noise transmission.
Refrigerant Piping
Guidance on connecting refrigerant lines to the unit.
Refrigerant and Chilled Water Piping Access
Locations of knockouts for refrigerant and water piping access.
Chilled Water Piping
Guidance on sizing, designing, and installing chilled water piping.
Condensate Drain
Instructions for installing a trapped condensate drain line.
Fan Motors and Drives
Information about factory-installed fan motors and drive packages.
Power Supply and Wiring
Guidance on connecting the unit to the electrical power supply.
Three Stage Operation
Instructions for converting a 2-stage unit to 3-stage operation.
Connecting Ductwork
Guidance on connecting ductwork to the unit's discharge and return.
Return-Air Filters
Information on filter types, sizes, and installation.
Start-Up
40RFA and 40RFQ ONLY
Specific start-up checks for 40RFA and 40RFQ models.
Adjusting TXV for Superheat
Procedure for adjusting the thermostatic expansion valve for superheat.
Service
Panels
Information on removing and replacing unit panels for service.
SUPPLY FAN
Information related to the unit's supply fan.
Supply Fan (Direct-Drive)
Details on the direct-drive vane axial fan system.
EVALUATING MOTOR SPEED
How to assess the speed of the ECM blower motor.
SELECTING FAN SPEED
Procedure for setting the fan speed based on requirements.
Low Speed Fan Adjustment
Adjustment of fan speed using DIP switches on the control board.
FAN FAULT DETECTION
How the system detects and prevents operation with a faulty supply fan.
FREEZE PROTECTION
Information on protecting the compressor from freezing conditions.
Service Access for Supply Fan and Motor
Procedures for accessing the supply fan and motor.
Removing the Motor and Fan Assembly
Steps to remove the motor and fan from the unit.
Disassembling Motor and Fan Assembly
Steps to take apart the motor and fan assembly.
Reassembly of Motor and Fan Assembly
Steps to put the motor and fan assembly back together.
Reinstalling Motor and Fan Assembly
Steps to reinstall the motor and fan assembly.
Cleaning Insulation
Guidance on cleaning the unit's internal insulation.
Replacing Filters
Instructions for removing and installing air filters.
Condensate Drains
Maintaining clear condensate drain lines.
Chilled Water Coil Freeze Protection
Methods to prevent freezing of the chilled water coil.
Coil Removal
Steps for removing the unit's coil.
Cleaning Cooling Coil
Procedures for cleaning the unit's cooling coil.
Maintenance
Quarterly Inspection
Routine checks performed quarterly and after initial start.
Seasonal Maintenance
Maintenance tasks performed at the beginning of each season.
Fan Performance
General Fan Performance Notes
Notes and guidelines for interpreting fan performance data.
Start-Up Checklist
Preliminary Information
Basic identification details for outdoor and indoor units.
Pre-Start-Up
Checks to perform on the outdoor and indoor units before starting.
Controls
Verification of thermostat and fan control wiring connections.
Indoor Unit
Checks related to the indoor unit's water and filters.
Piping
Checks for refrigerant and water piping systems.
Check Voltage Imbalance
Measuring and calculating voltage imbalance for system safety.
Check Indoor Fan Motor Speed and Record
Recording fan motor speed after initial run.
Record the Following Measurements
Section for recording various operational parameters.

Table of Contents