Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Sanyo Manuals
Air Conditioner
C4232A
Installation instructions manual
Sanyo C4232A Installation Instructions Manual
Hide thumbs
Also See for C4232A
:
Specifications
(3 pages)
,
Specifications
(3 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
page
of
50
Go
/
50
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Important
Please Read before Starting
General
Tools Required for Installation (Not Supplied)
Accessories Supplied with Unit
Optional Copper Tubing Kit
Type of Copper Tube and Insulation Material
Additional Materials Required for Installation
Operating Range
Tubing Length
Selecting the Installation Site
Indoor Unit
Outdoor Unit
Air Discharge Chamber for Top Discharge
Wind Shield for "CL" Model
How to Install the Indoor Unit
I Recessed Type (XS Type)
Suspending the Indoor Unit
Preparation for Suspending
Placing the Unit Inside the Ceiling
Installing the Drain Piping
Checking the Drainage
Before Installing the Ceiling Panel
Installing the Ceiling Panel
When Removing the Ceiling Panel for Servicing
Duct for Fresh Air
I Ceiling-Mounted Type (TS Type)
Suspending the Indoor Unit
Duct for Fresh Air
Installing the Drain Piping
I Wall-Mounted Type (KS Type)
Removing the Wall Fixture from the Unit
Selecting and Making a Hole
Installing the Wall Fixture Onto Wooden or Gypsum Wall
Removing the Casing to Install the Indoor Unit
Removing the Grille to Install the Indoor Unit
Preparing the Indoor Side Tubing
Wiring Instructions
Wiring Instructions for Inter-Unit Connections
Shaping the Tubing
Installing the Drain Hose
How to Install the Remote Control Unit
I Wireless Remote Control Unit
Mounting on a Wall (Except KS2432A)
Mounting on a Wall (KS2432A Only)
Installing the Wired Remote Control Unit
ADDRESS SWITCHES (Except KS2432A)
Finding the Address Switches
Switch Positions for 2 Units or 2 Groups of Units
How to Install the Outdoor Unit
Removing the Protective Spacer for Transportation
Installing the Outdoor Unit
Tubing Direction
Electrical Wiring
General Precautions on Wiring
Recommended Wire Length and Wire Diameter for Power Supply System
Wiring System Diagram
Examples of Incorrect Wiring
How to Connect Wiring to the Terminal
How to Process Tubing
Use of the Flaring Method
Flaring Procedure with a Flare Tool
Precaution before Connecting Tubes Tightly
Precautions During Brazing
Connecting Tubing between Indoor and Outdoor Units
Insulating the Refrigerant Tubing
Taping the Tubes
Finishing the Installation
Air Purging
Air Purging with a Vacuum Pump (for Test Run)
Test Run
Preparing for Test Run
Performing Test Run
Performing Test Run with Optional Wired
Remote Control Unit
I Basic Functions of the Service Valves
I Pump down
Advertisement
Quick Links
1
Table of Contents
2
General
3
Indoor Unit
4
Outdoor Unit
5
Remote Control Unit
Download this manual
- Split System Air Conditioner -
CONTENTS
IMPORTANT
Please Read Before Starting
.................................. 2
1. GENERAL
............................................................. 3
1-1.
Tools Required for Installation (not supplied)
1-2.
Accessories Supplied with Unit
1-3.
Optional Copper Tubing Kit
1-4.
Type of Copper Tube and Insulation Material
1-5.
Additional Materials Required for Installation
1-6.
Operating Range
1-7.
Tubing Length
2. SELECTING THE INSTALLATION SITE
............ 7
Indoor Unit
Outdoor Unit
2-1.
Air Discharge Chamber for Top Discharge
2-2.
Wind Shield for "CL" Model
3. HOW TO INSTALL THE INDOOR UNIT
............ 10
I Recessed Type (XS Type)
................................ 10
3-1.
Suspending the Indoor Unit
3-2.
Preparation for Suspending
3-3.
Placing the Unit Inside the Ceiling
3-4.
Installing the Drain Piping
3-5.
Checking the Drainage
3-6.
Before Installing the Ceiling Panel
3-7.
Installing the Ceiling Panel
3-8.
When Removing the Ceiling Panel for
Servicing
3-9.
Duct for Fresh Air
I Ceiling-Mounted Type (TS Type)
..................... 18
3-10. Suspending the Indoor Unit
3-11. Duct for Fresh Air
3-12. Installing the Drain Piping
I Wall-Mounted Type (KS Type)
........................ 22
3-13. Removing the Wall Fixture from the Unit
3-14. Selecting and Making a Hole
3-15. Installing the Wall Fixture onto Wooden or
Gypsum Wall
3-16. Removing the Casing to Install the Indoor Unit
3-17. Removing the Grille to install the Indoor Unit
3-18. Preparing the Indoor Side Tubing
3-19. Wiring Instructions
3-20. Wiring Instructions for Inter-Unit Connections
3-21. Shaping the Tubing
3-22. Installing the Drain Hose
4. HOW TO INSTALL THE REMOTE
CONTROL UNIT
................................................. 33
I Wireless Remote Control Unit
4-1.
Mounting on a Wall (except KS2432A)
4-2.
Mounting on a Wall (KS2432A only)
I Wired Remote Control Unit (Option) (except 2432A)
4-3.
Installing the Wired Remote Control Unit
85464359249001
INSTALLATION INSTRUCTIONS
Page
5. ADDRESS SWITCHES (except KS2432A)
....... 36
6. HOW TO INSTALL THE OUTDOOR UNIT
........ 37
7. ELECTRICAL WIRING
....................................... 38
8. HOW TO PROCESS TUBING
........................... 41
9. AIR PURGING
.................................................... 44
10.TEST RUN
.......................................................... 47
1
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor units
XS2432 (PNR-XS2432)
TS2432
KS2432
KS2432A
KS3032
XS3632 (PNR-XS3632)
TS3632
KS3632
XS4232 (PNR-XS3632)
TS4232
Power Supply: 60Hz, single-phase, 208/230 V
Units should be installed by licensed contractor
according to local code requirements
5-1.
Finding the Address Switches
5-2.
Switch Positions for 2 Units or 2 Groups of
Units
6-1.
Removing the Protective Spacer for
Transportation
6-2.
Installing the Outdoor Unit
6-3.
Tubing Direction
7-1.
General Precautions on Wiring
7-2.
Recommended Wire Length and Wire
Diameter for Power Supply System
7-3.
Wiring System Diagram
7-4.
Examples of Incorrect Wiring
7-5.
How to Connect Wiring to the Terminal
8-1.
Use of the Flaring Method
8-2.
Flaring Procedure with a Flare Tool
8-3.
Precaution before Connecting Tubes Tightly
8-4.
Precautions during Brazing
8-5.
Connecting Tubing between Indoor and
Outdoor Units
8-6.
Insulating the Refrigerant Tubing
8-7.
Taping the Tubes
8-8.
Finishing the Installation
I
Air Purging with a Vacuum Pump
(for Test Run)
10-1. Preparing for Test Run
10-2. Performing Test Run
10-3. Performing Test Run with Optional Wired
Remote Control Unit
I Basic Functions of the Service Valves
I Pump Down
SANYO FISHER COMPANY
A DIVISION OF SANYO NORTH
AMERICA CORPORATION
21605 Plummer Street
Chatsworth, CA91311
S4359249
Outdoor units
C2432A
CL2432A
C3032A
CL3032A
C3632A
CL3632A
C4232A
CL4232A
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the C4232A and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Sanyo C4232A
Air Conditioner Sanyo 42TS32A Specifications
Ceiling suspended air conditioner (3 pages)
Air Conditioner Sanyo 42XLS32A Specifications
Ceiling recessed (4-way) air conditioner (3 pages)
Air Conditioner Sanyo C4232 Technical Data & Service Manual
Split system air conditioner (66 pages)
Air Conditioner Sanyo XS4232 Technical Data And Service Manual
(66 pages)
Air Conditioner Sanyo 42TW72R Specifications
Ceiling suspended air conditioner (2 pages)
Air Conditioner Sanyo 42XH72R Dimensional Information
Sanyo air conditioner dimensional data sheet (1 page)
Air Conditioner Sanyo C4272R Service Manual
Sanyo split system air conditioner service manual (181 pages)
Air Conditioner Sanyo THW4272R Specifications
Ceiling suspended air conditioner (2 pages)
Air Conditioner Sanyo XHW4272R Specifications
Ceiling recessed air conditioner (2 pages)
Air Conditioner Sanyo C4272R S/C Installation Instructions Manual
Sanyo split system heat pump air conditioner installation instructions (111 pages)
Air Conditioner Sanyo SPW-X483GH56 Installation Instruction
Eco multi system air conditioner (91 pages)
Air Conditioner Sanyo TS2422B Instruction Manual
(20 pages)
Air Conditioner Sanyo 48RS22N Service Manual
Split system air conditioner (41 pages)
Air Conditioner Sanyo 26 series Installation Instructions Manual
Split system heat pump air conditioner (110 pages)
Air Conditioner Sanyo C2432 Installation Instructions Manual
Split system air conditioner (17 pages)
Air Conditioner Sanyo KS0971 Technical & Service Manual
Dc inverter split system air conditioner (81 pages)
Summarization of Contents
General Installation Information
Tools Required for Installation
Lists essential tools needed for installation that are not supplied with the unit.
Accessories Supplied with Unit
Details the accessories included with the air conditioning unit package.
Optional Copper Tubing Kit
Information regarding the availability and purchase of optional copper tubing kits.
Type of Copper Tube and Insulation Material
Specifies the required types and dimensions for copper tubing and insulation.
Additional Materials Required for Installation
Lists supplementary materials needed for the installation process.
Operating Range
Defines the acceptable temperature ranges for unit operation.
Tubing Length Guidelines
Provides guidelines and limitations for the length of refrigerant tubing.
Selecting the Installation Site
Indoor Unit Site Selection
Guidelines for choosing the optimal location for the indoor unit.
Outdoor Unit Site Selection
Guidelines for choosing the optimal location for the outdoor unit.
Air Discharge Chamber for Top Discharge
Instructions for installing an air discharge chamber for top discharge.
Wind Shield for "CL" Model
Recommendations for using wind shields with CL model outdoor units.
How to Install the Indoor Unit
Suspending the Recessed Indoor Unit
Steps to suspend the recessed indoor unit using suspension bolts.
Preparation for Suspending Recessed Unit
Prepare the ceiling for unit suspension by making holes as per diagram.
Placing the Unit Inside the Ceiling
Position the indoor unit within the ceiling, ensuring proper suspension.
Installing the Drain Piping
Connect and install the drain piping system for the indoor unit.
Checking the Drainage
Test the drain system by pouring water to check for smooth flow.
Before Installing the Ceiling Panel
Remove air-intake grille and filter prior to ceiling panel installation.
Installing the Ceiling Panel
Attach the ceiling panel to the indoor unit and secure wiring.
Removing the Ceiling Panel for Servicing
Procedure to remove the ceiling panel for maintenance access.
Duct for Fresh Air
Install air-intake chamber and duct connection for fresh air intake.
Suspending the Ceiling-Mounted Indoor Unit
Steps for suspending ceiling-mounted indoor units with suspension bolts.
Installing the Drain Piping
Connect drain piping from indoor unit outlet, ensuring slope.
Removing the Wall Fixture from the Unit
Remove wall fixture set screws for KS models.
Selecting and Making a Hole
Select and drill wall holes for tubing passage for KS models.
Installing the Wall Fixture onto Wooden or Gypsum Wall
Securely mount the wall fixture onto wooden or gypsum walls.
Removing the Casing to Install the Indoor Unit
Steps to remove the casing for indoor unit installation.
Removing the Grille to Install the Indoor Unit
Steps to remove the grille for internal access on KS2432A.
Preparing the Indoor Side Tubing
Prepare tubing for various exit directions from the indoor unit.
Wiring Instructions
General precautions and system diagram for wiring.
Wiring Instructions for Inter-Unit Connections
Route and connect inter-unit wiring to the indoor unit terminals.
Shaping the Tubing
Shape refrigerant tubing and drain hose for wall passage.
Installing the Drain Hose
Install the drain hose, ensuring proper slope and insulation.
How to Install the Remote Control Unit
Wireless Remote Control Unit Installation
Guidelines for installing the wireless remote control.
Mounting on a Wall (except KS2432A)
Procedures for removable and non-removable wireless remote mounting.
Mounting on a Wall (KS2432A only)
Specific mounting methods for the KS2432A wireless remote.
Wired Remote Control Unit Preparation
Steps to prepare the unit for wired remote control connection.
Installing the Wired Remote Control Unit
Steps for wall-mounting the wired remote control unit.
Address Switches (except KS2432A)
Finding the Address Switches
Locate address switches on remote control and indoor unit.
Switch Positions for Multiple Units
Table showing switch settings for controlling 2 units or groups.
How to Install the Outdoor Unit
Removing the Protective Spacer for Transportation
Remove transport spacers from the outdoor unit.
Installing the Outdoor Unit
Mount and anchor the outdoor unit on a solid base.
Tubing Direction
Extend tubing in four directions by preparing knockout holes.
Electrical Wiring
General Precautions on Wiring
Safety guidelines and precautions for electrical wiring.
Recommended Wire Specs
Wire length and diameter recommendations for power supply.
Wiring System Diagram
Illustrates the electrical connections between units.
Examples of Incorrect Wiring
Demonstrates common wiring errors and their consequences.
How to Connect Wiring to the Terminal
Procedures for connecting solid core and stranded wires.
How to Process Tubing
Use of the Flaring Method
Explains the flaring technique for connecting refrigerant tubes.
Flaring Procedure with a Flare Tool
Detailed steps for flaring copper tubes using a tool.
Precaution before Connecting Tubes Tightly
Precautions for aligning and securely connecting tubes.
Precautions during Brazing
Safety measures during the brazing process.
Connecting Tubing between Indoor and Outdoor Units
Steps to tightly connect refrigerant tubing between units.
Insulating the Refrigerant Tubing
Insulate refrigerant tubing to prevent condensation.
Taping the Tubes
Bundle and tape refrigerant tubes and drain hose.
Finishing the Installation
Seal wall openings with putty to prevent drafts.
Air Purging
Air Purging with Vacuum Pump
Preparation and leak testing for air purging with a vacuum pump.
Leak Test
Procedure for checking refrigerant system for leaks.
Evacuation
Evacuate the system using a vacuum pump to remove moisture.
Charging additional refrigerant
Add refrigerant based on calculated tubing length.
Finishing the Job
Final steps for air purging and refrigerant charging.
Test Run
Preparing for Test Run
Checklist for system readiness before performing the test run.
Performing Test Run
Steps to operate the unit and verify normal performance.
Performing Test Run with Optional Wired Remote Control Unit
Test run procedure using the optional wired remote control.
Pump Down Procedure
Pump down procedure
Steps to collect refrigerant gas for servicing or moving the unit.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the C4232A and is the answer not in the manual?
Questions and answers