Download Print this page

Sanyo 42TW72R Specifications

Ceiling suspended air conditioner
Hide thumbs Also See for 42TW72R:

Advertisement

Split System Submittal Data
System: 42TW72R
Ceiling Suspended Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
(A)
Fuse Size, Max.
(A)
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
(W)
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
(RPM)
No. Motors
(High)
CFM
(A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
(RPM, High)
No. Poles
No. Motors
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
(in.)
Drain Connection Size
Indoor/Outdoor: THW4272R/C4272R
General Data (at 230V)
230/208/1/60
15-40 Indoor-Outdoor
15-40 Indoor-Outdoor
DC Rotary Inverter
(A)
18.1-31.0
Propeller
18-7/64-2
Direct Inverter
8 - 830
(W)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rif ed
2-12.7
11.62
(in.)
Centrifugal
5-29/32 - 4
3 & Auto
4-1099
(W)
1-100
1130/950/775
(A)
Aluminum Fin & Copper Tube
Slit Plate - Inner Rif ed
3-14.9
9/32"
(in.)
(1-1/4)
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max
-
Lift Difference, Max
Line Size
Line Size
Dimensions
Indoor Unit
2-90
3531
Outdoor Unit
19.7
Weight
Net
Shipping
3/8"
Shipping Volume
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
44
0.8
Amps
Power Inputs
Outdoor Sound Rating
3.51
Electric Expansion Valve
50 (Outdoor lower), 100 (Outdoor higher)
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
9-7/16 x 62-1/32 x 26-3/8
(Crated)
12-15/32 x 66-1/16 x 31-1/6
(Uncrated)
48-7/16 x 37 x 13-3/8
(Crated)
52-3/8 x 39-31/32 x 16-3/32
Indoor
(lbs.)
84
(lbs.)
97
Indoor
(cu.ft.)
14.8
(BTU/H)
39,000 (9,500-39,000)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
Print Form
R410A
7.94
Flare
165
3/8"
5/8"
H x W x D
Outdoor
220
240
Outdoor
19.5
23,560
15,440
15.6
12.6
21.1/23.3
4,140/4,140
53

Advertisement

loading

Summary of Contents for Sanyo 42TW72R

  • Page 1 Split System Submittal Data System: 42TW72R Indoor/Outdoor: THW4272R/C4272R Ceiling Suspended Air Conditioner Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data (at 230V) Power V/PH/Hz Circuit Ampacity Fuse Size, Max. Compressor No. used R.L. Amps - L.R. Crankcase Heater...