Rigol DP932 Quick Manual

Rigol DP932 Quick Manual

Programmable linear dc power supply

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DP932 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rigol DP932

  • Page 2 • RIGOL products are covered by P.R.C. and foreign patents, issued and pending. • RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at the company's sole decision. • Information in this publication replaces all previously released materials.
  • Page 3: Safety Requirement

    Indicates a potentially hazardous situation or practice which, if not avoided, will result in serious injury or death. CAUTION Indicates a potentially hazardous situation or practice which, if not avoided, could result in damage to the product or loss of important data. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 4: Measurement Category

    Measurement category III is for measurements performed in the building installation. Examples are measurements on distribution boards, circuit-breakers, wiring (including cables, bus-bars, junction boxes, switches and socket-outlets) in the fixed installation, and equipment for industrial use and some other Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 5: Ventilation Requirement

    Below +65℃: ≤90%RH (without condensation) WARNING To avoid short circuit inside the instrument or electric shock, never operate the instrument in a humid environment. Altitude • Operating: below 3 km • Non-operating: below 15 km Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 6: Care And Cleaning

    For example, outdoor areas. Safety Class Class 1 – Grounded Product Care and Cleaning Care Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 7: Environmental Considerations

    Please contact your local authorities for disposal or recycling information. https://int.rigol.com/services/services/declaration You can click on the following link to download the latest version of the RoHS&WEEE certification file. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 8: Document Overview

    This manual gives you a quick overview of the front and rear panel, user interface, and basic operation methods of DP900 Series Programmable DC Power Supply. http:// For the latest version of this manual, download it from the official website of RIGOL ( www.rigol.com Publication Number...
  • Page 9: General Inspection

    The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument. 2. Inspect the instrument In case of any mechanical damage,missing parts, or failure in passing the electrical and mechanical tests, contact your RIGOL sales representative.
  • Page 10: Production Introduction

    Production Introduction Production Introduction Appearance and Dimensions Figure 4.1 Front View Figure 4.2 Side View Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 11: Front Panel

    Production Introduction Front Panel This section introduces the front panel of the DP900 series by taking DP932A (as shown in the figure below) as an example. The model-specific features will be introduced in particular. Figure 4.3 DP900 Front Panel 1. LCD 4.3-inch TFT touch screen to display the the system parameter settings, output...
  • Page 12 4. Preset Key Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 13 Logger. Press this key to enter the Utility setting interface, in which you can set parameters related to remote interface, system, outputs, and options. Besides, you can also set the display. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 14 10. Power Switch Key Press this key to power on or off the instrument. Rear Panel This section introduces the rear panel of DP900 series by taking DP932A (as shown in the figure below) as an example. Figure 4.5 DP900 Rear Panel...
  • Page 15: User Interface

    Note[1]: Digital I/O is optional for DP932U and not available for DP932E User Interface > Display to assess the interface as shown in the figure below. This section introduces the meter-view display of the power supply. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 16 CC: The output is in constant current mode. UR: The output is unregulated. 2-Wire sense connection Actual output power Navigation icon Voltage setting value Over-voltage protection (OVP) status indicator, indicating the present OVP on/off state Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 17 : network connected. : a USB device is detected. : the instrument is in remote control. : the beeper is turned off. : the beeper is turned on. : downloading the firmware upgrade file. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 18: To Prepare For Use

    To Prepare for Use Connecting to Power DP900 series power supply supports various AC power inputs. The AC selector setting on the rear panel differs when input power is different, as shown in the table below. Table 5.1 AC input power specifications (including AC selector setting)
  • Page 19: Power-On Inspection

    This series power supply provides three-channel outputs, which share the same connection method. Please follow the instructions below to connect the outputs. Method 1: Connect wires to the front of the terminals as shown in (A). Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 20: Replacing The Fuse

    (please refer to 4. Remove the original fuse and insert the proper fuse into the fuse holder (please Replacing the Fuse refer to the “Input power requirement” or Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 21 To avoid personal injury, please power off the power supply before replacing the fuse; to avoid electric shock or fire, select the input power that matches the actual input voltage and use the correct fuse before connecting to power. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 22: Using The Built-In Help System

    2 seconds and starts to upgrade. Others Tap Others to enter the interface in which you can obtain the following help topics: • View the last displayed message • View remote command error queue Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 23 Using the Built-in Help System • Contact RIGOL Technical Support • Open source statement Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 24: Troubleshooting

    The following failures may occur during the use of the instrument. Please first try to handle the problem according to the following methods; if the problem remains unsolved, please contact RIGOL and provide the device information of your instrument (by tapping >...
  • Page 25 USB storage device. c. Restart the instrument and insert the USB storage device to check. d. If the USB storage device still cannot work normally, please contact RIGOL. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 26: Remote Control

    • PC Software You can use the PC software to send commands to control the instrument remotely. Ultra Sigma of RIGOL is recommended. You can log in to RIGOL official http://www.rigol.com website ( ) to download the software.
  • Page 27 For more information about this instrument, please refer to the relevant manuals by http://www.rigol.com logging in to the official website of RIGOL ( ) to download them. DP900 User Guide: introduces the functions of the instrument and the operation •...

Table of Contents