Replacing, moving, or adding hard drives
In this section
Replacing hard drives ............................................................................................................................. 24
Moving drives and arrays ....................................................................................................................... 27
Adding drives ........................................................................................................................................ 28
Identifying the status of a hard drive
When a drive is configured as a part of an array and connected to a powered-up controller, the condition
of the drive can be determined from the illumination pattern of the hard drive status lights (LEDs). The table
("Hot-plug SCSI hard drive LED
illumination patterns.
Hot-plug SCSI hard drive LED combinations
Activity
Online LED
LED (1)
(2)
On, off, or
On or off
flashing
On, off, or
On
flashing
combinations" on page 22) describes the meanings of the different
Fault LED
Interpretation
(3)
Flashing
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off
The drive is online and is configured as part of an array.
If the array is configured for fault tolerance and all other drives in the
array are online, and a predictive failure alert is received or a drive
capacity upgrade is in progress, you may replace the drive online.
Replacing, moving, or adding hard drives 22