Technical Specifications; Table 2. Technical Specifications - Intel RS2BL080 - RAID Controller Hardware User's Manual

Hardware user guide
Hide thumbs Also See for RS2BL080 - RAID Controller:
Table of Contents

Advertisement

Jumper
Description
JT12
Individual Drive Fault LED
header
JT13
Universal Asynchronous
Receiver/Transmitter (UART)

Technical Specifications

RAID-on-Chip (ROC )
Operating voltage
Card size
Array interface to host
SAS/SATA bus speed
SAS/SATA ports
Physical and virtual drive
support
Cache
Firmware
Compatible devices
Cabling
Redundant configuration
Enclosure management
Enclosure support
14
Type
8 x 2 header
4-pin connector

Table 2. Technical Specifications

Specification
Indicates drive faults. There is one LED per port.
When lit, each LED indicates the corresponding
drive has failed or is in the Unconfigured-Bad state.
The LEDs function in a direct-attach configuration
(there are no SAS expanders). Direct attach is
defined as a maximum of one drive connected
directly to each port.
Note:
This header is used for RAID controllers
with internal SAS ports only.
For factory and debug use
®
Intel
RAID Controller RS2BL080
LSISAS2108 Integrated ROC, 800 MHz
+3.3 V, +12 V
Low profile, extended half-length (6.6-inch, MD2)
PCI Express* Revision 2.0, x8 lane width 5.0 Gbps
Up to 6 Gbps per port, point-to-point
2x4 internal ports, 32 devices per port with expanders
32 physical drives, 64 virtual drives, and 16 RAID arrays per
controller
512 MB DDR2 800 MHz SDRAM, optional battery backup
8 MB in reflashable flash ROM
2.5-inch and 3.5-inch SAS or SATA II drives
Non disk devices including expanders
Can support drives of mixed capacity
Small, thin cables that do not restrict airflow
Shared connectors for multiple drives
32 KB NVRAM and config-on-disk (COD)
SGPIO
In-band and out-of-band SES
Assumes one SEP per enclosure
Intel® RAID Controller RS2BL080 Hardware User's Guide
Comments

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents