Summarization of Contents

Features and Technical Specifications
Features
Lists key features of the CDTX-111, including display, compensation, and alarm outputs.
Technical Specifications
Details the technical specifications such as measurement ranges, accuracy, and operating conditions.
Installation
Dimensions
Provides overall dimensions and panel-mounting details for the CDTX-111 unit.
Panel Cut-out
Specifies the required panel cut-out dimensions and mounting method for installation.
User Interface and Description
Describes the front panel elements, including the LED display, alarm lights, and control buttons.
Connection
Details the wiring directions for the connection terminals of the CDTX-111 instrument.
Setting and Operation
Switch Measuring and Setting Mode
Explains how to switch between the instrument's measuring and setting modes using the MENU button.
Menu Structure
Illustrates the menu structure for setting alarms, including high and low alarm values.
Parameter Setting and Operation
Details various parameter settings like alarms, calibration, and output configurations.
Set Alarm
Describes how to set high (AH) and low (AL) alarm values and hysteresis for the monitor.
Calibration
Covers calibration intervals and procedures for the conductivity sensor and temperature compensation.
CAL—conductivity sensor manual calibration
Provides step-by-step instructions for manually calibrating the conductivity sensor.
CO、C100—temperature calibration
Explains the process for calibrating the instrument's temperature compensation at 0°C and 100°C.
CC—auto/manual temperature compensation switch
Describes how to switch between automatic and manual temperature compensation modes.
C1-C-set temperature compensation coefficient
Details how to set the temperature compensation coefficient for different solutions.
CH-set manual temperature
Explains how to set the manual temperature value when using manual compensation.
Set Current Output
Guides on configuring the 4-20mA current output, including input source and range.
FSIS、FSIE—set current output start and end value
Details how to set the start and end values for the 4-20mA current output.
FSI—select the input for the current output
Explains how to select the input source (conductivity or temperature) for the current output.
FlgS、FIgE、FICS、FICE—set input value range for the current output
Describes setting the input value range for conductivity and temperature for the current output.
SHSP—Measurement Mode
How to select measurement modes like conductivity, resistivity, TDS, and temperature.
FACt—Restore Factory Setting
Instructions on how to restore the instrument to its factory default settings.
Sensor
Sensor Features
Highlights the key features of the conductivity sensor, such as sensitivity and material.
Sensor Parameters
Provides detailed parameters for different sensor models, including medium, cell constant, and range.
The Use Situation of Conductivity Sensor
Lists conductivity values for various liquids at 25°C.
Sensor Dimension (Unit: mm)
Shows the physical dimensions of the conductivity sensor in millimeters.
Maintenance
Provides essential maintenance guidelines for the conductivity sensor and instrument.