Omega FPD3100-D Series User Manual

Omega FPD3100-D Series User Manual

12mm lc digital with analog output options

Advertisement

Quick Links

User's Guide
Shop online at
omega.com
®
e-mail: info@omega.com
For latest product manuals:
www.omegamanual.info
FPD3100-D and FPD3100-D-A Series
12mm LC Digital Display
with Analog Output Options

Advertisement

Table of Contents
loading

Summary of Contents for Omega FPD3100-D Series

  • Page 1 User’s Guide Shop online at omega.com ® e-mail: info@omega.com For latest product manuals: www.omegamanual.info FPD3100-D and FPD3100-D-A Series 12mm LC Digital Display with Analog Output Options...
  • Page 2 For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
  • Page 3: Table Of Contents

    index Product Overview Page 4 General Product Functionality …………………………………………………………. Type FPD3100-D Digital Register Page 5 Program Overview …………………………………………………………. Page 6 Set-up Functions …………………………………………………………. Page 7 Wiring Diagram …………………………………………………………. Page 7 Parts Listing …………………………………………………………. Page 8 Technical Specifications …………………………………………………………. Type FPD3100-D-A Digital Register Page 10 Program Overview ………………………………………………………….
  • Page 4 Please read and retain this instruction manual to assist you in the operation of this product. This Instruction Manual provides a instruction guide on the set-up and programming of the Type FPD3100-D and FPD3100-D-A, 12mm LCD Digital Register. PRODUCT OVERVIEW SYSTEM DESCRIPTION OF THE G 012P Functions and features...
  • Page 5: Program Overview

    FPD3100-D DIGITAL REGISTER Program Overview GENERAL Configuration of the FPD3100-D is done at SETUP-level. SETUP-level is reached by pressing the PROG/ENTER key for 7 seconds; at which time, setup will be displayed. In or- der to return to the operator level, PROG will have to be pressed for three seconds.
  • Page 6: Set-Up Functions

    FPD3100-D DIGITAL REGISTER Set-up Functions SETUP PARAMETERS TOTAL/BATCH TOTAL SETUP - 1.1 determines the measurement unit for total and batch total The following units can be selected: L - m3 - UKGAL - USGAL - UKbbl - USbbl - OILbbl Please note that the K-Factor entered in 4.1 should be in pulses per litre and unit adjustment is done automatically.
  • Page 7: Wiring Diagram

    FPD3100-D DIGITAL REGISTER Wiring Diagram and Parts Description The FPD3100 unit cam only accept a reed switch input, this sensor has been selected as the most common sensor and requires very little power with small effect on battery life. The 2 position terminal block is not polarity conscious so the reed switch wires can be connected in any order.
  • Page 8: Technical Specifications

    FPD3100-D DIGITAL REGISTER Technical Specifications GENERAL Display Type High intensity reflective numeric and alphanumeric LCD, UV-resistant. Digits Seven 12mm (0.47") and seven 8mm (0.31"). Various symbols and measuring units. Refresh rate Flow Rate: once per second. Total: 8 times/second after key press to one second. Enclosures General Aluminium with Polycarbonate window, silicone and EPDM gaskets.
  • Page 9 NOTES...
  • Page 10: Program Overview

    FPD3100-D-A DIGITAL REGISTER Program Overview PROGRAMMING SETUP-LEVEL GENERAL Configuration of the FPD3100-D-A is done at SETUP-level. SETUP-level is reached by pressing the PROG/ENTER key for 7 seconds; at which time, setup will be displayed. In order to return to the operator level, PROG will have to be pressed for three seconds.
  • Page 11: Set-Up Functions

    FPD3100-D-A DIGITAL REGISTER Set-up Functions SETUP PARAMETERS TOTAL/BATCH TOTAL SETUP - 1.1 determines the measurement unit for total and batch total The following units can be selected: L - m3 - UKGAL - USGAL - UKbbl - USbbl - OILbbl Please note that the K-Factor entered in 5.1 should be in pulses per litre and unit adjustment is done automatically.
  • Page 12 FPD3100-D-A DIGITAL REGISTER Set-up Functions 4 - ALARM With these settings, it is determined how the flow rate will be monitored and the functionality of the transistor outputs be deter- mined. ALARM Setting the function of the Alarm The following settings can be selected: Off: Function disabled.
  • Page 13: Wiring Diagram

    FPD3100-D-A DIGITAL REGISTER Set-up Functions 7 - PULSE OUTPUT One transistor output is available as scaled pulse output according to the accumulated total DECIMALS Sets the decimals for the pulses per 7.3 WIDTH OF PULSE The pulse width determines the time that the transistor will be switched; in other words the pulse length.
  • Page 14: Outputs

    FPD3100-D-A DIGITAL REGISTER Outputs Pulse Output Example for scaled 1 pulse per litre the output must be programmed as follows: In menu 7.1 set 2222.22 In menu 7.2 set 10 or more (10mS or more if needed) In menu 7.3 set 1.00 Example Pulse/Alarm Output Setup Passive 4-20mA setup...
  • Page 15: Parts Listing

    FPD3100-D-A DIGITAL REGISTER Parts Description...
  • Page 16 FPD3100-D-A DIGITAL REGISTER Technical Specifications GENERAL Display Type High intensity reflective numeric and alphanumeric LCD, UV-resistant. Digits Seven 12mm (0.47") and seven 8mm (0.31"). Various symbols and measuring units. Refresh rate Flow Rate: once per second. Total: 8 times/second after key press to one second. Enclosures General Aluminium with Polycarbonate window, silicone and EPDM gaskets.
  • Page 17: Technical Specifications

    FPD3100-D-A DIGITAL REGISTER Technical Specifications OUTPUTS Analog output Function transmitting flow rate. Type Passive 4-20mA output - output loop powered. Accuracy 10 bit. Update 8 times a second. Software function to calibrate the 4.00mA and 20.00mA levels precisely within set-up. Minimum operating voltage 8V DC Power supply...
  • Page 18: List Configuration Settings

    List of configuration settings SETTING DEFAULT DATE : DATE : 1 - TOTAL Enter your settings here 11 unit 12 decimals 0000000 2- ACCMULATED TOTAL 21 unit 22 decimals 0000000 3 - FLOWRATE 31 unit 32 time unit /min 33 decimals 0000000 34 calculation / pulses 35 cut-off time...
  • Page 19: Wall Mount Bracket Dimensions

    Wall Mount Bracket The FPD3100 series is available with a Wall Mount Bracket option for applications requiring remote mount display. Both the models -D and –D-A are available with this option. Following is a dimensional drawing for the wall mount bracket.
  • Page 20 Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
  • Page 21 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers &...

This manual is also suitable for:

Fpd3100-d-a seriesFpd3100

Table of Contents