Table of Contents

Advertisement

Quick Links

SOFTOWER
ECOPERLA
SOFTOWER
WATER SOFTENER
original product of Ecoperla
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOFTOWER L and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
Safety Measures
Crucial safety precautions for installation, operation, and maintenance of the device.
Water Softening
Explanation of water hardness, its types, and its adverse effects on daily life and appliances.
Description of Operation
Explains how the ion exchange resin removes calcium and magnesium ions to soften water.
Operation and Maintenance
User responsibilities for operation, including salt replenishment and pre-filter replacement.
Installation and Start-Up
Requirements
Essential working conditions for trouble-free operation, including pressure, temperature, and power supply.
Installation Diagram
Visual guide showing the correct order of connecting devices within the water softening system.
Control Valve
Details about the control valve, its display, and connection types.
Installation and Start-Up
Step-by-step instructions for preparing the installation and starting up the device.
Programming
Information Displayed During Operation Mode
Overview of the information displayed on the valve panel during normal operation.
Initial Settings
Guide to configuring essential initial parameters for the water softener.
Time Setting
Guide on how to set the current time on the device's control panel.
Language Selection
Instructions for selecting the display language for the control valve.
Entering the Basic Settings
How to enter initial system settings after language selection.
Initial Hardness
Procedure for inputting the initial water hardness value into the system.
Residual Hardness
Setting the desired residual hardness level after water softening.
Days Between Regenerations
Configuring the number of days between automatic regeneration cycles.
Setting Regeneration Time
Setting the specific time of day for regeneration cycles to occur.
Individual Mode Setting
Options for customizing advanced operational parameters beyond basic settings.
Setting Table
A comprehensive table detailing various setting parameters for different Softower models.
Type of Filtration
Selecting the primary filtration mode, such as Softening or Filter.
Brining Time
Setting the duration for the brining stage during the regeneration process.
Backwash Time
Configuring the duration of the backwash cycle in the regeneration process.
Rinsing Time
Setting the duration for the rinsing stage after backwashing during regeneration.
Amount of Salt
Specifying the quantity of salt used during the regeneration process.
Capacity
Setting the ion exchange capacity of the softener.
Selection of Regeneration Frequency
Choosing how often the regeneration cycle should run, either automatically or manually.
Choice of Regeneration Type
Selecting the method of regeneration, such as delayed, mixed, or instant.
Output Signal Settings 1
Configuring the first output signal for external system integration or monitoring.
Output Signal Settings 2
Configuring the second output signal for additional external system integration or monitoring.
Service Alarm
Setting up reminders for periodic maintenance and service activities.
Salt Level Alarm
Configuring an alarm to notify when the salt level in the tank is low.
Regeneration Setting Table
A table summarizing regeneration settings based on capacity and type.
Work History
Accessing and viewing historical operational data of the water softener.
Number of Days Since Last Regeneration (Basic History)
Displays the count of days elapsed since the last regeneration cycle.
Water Amount Since Last Regeneration (Basic History)
Shows the total volume of water treated since the last regeneration.
History of Regeneration (Basic History)
Displays the total volume of treated water since the device was commissioned.
Daily Water Consumption (Basic History)
Records the daily water consumption patterns of the device.
Peak Flow (Basic History)
Shows the maximum water flow rate recorded during operation.
Software Version (Extended History)
Displays the current software version installed on the control valve.
Total Number of Days (Extended History)
Total duration in days since the device was put into operation.
Total Number of Regenerations (Extended History)
Total count of regeneration cycles performed since device commissioning.
Total Volume (Extended History)
Total volume of water processed by the device over its lifetime.
History of Errors (Extended History)
Logs of any error codes or malfunctions encountered by the control valve.
Operation
Operation of the Water Softener
Basic operation of the water softening system, including salt replenishment and regeneration.
General Information
Importance of regular maintenance for long-term, trouble-free operation and record-keeping.
List of Requirements for Proper Functioning
Key factors influencing the device's proper operation, including installation, water quality, and conditions.
User Operating Activities
Essential tasks for the user, such as pre-filter replacement, salt replenishment, and malfunction monitoring.
Medium Disinfection and Cleaning
Recommended procedures for maintaining the ion exchange medium's cleanliness and purity.
Interruptions in System Operation
Recommendations for disinfecting the softener if it's not used for an extended period.
Consumables
List of necessary consumables and their recommended replacement intervals.
Warranty Loss
Factors and actions that can lead to the loss of the device's warranty.
Service
Service Technician's Activities
Overview of annual maintenance tasks performed by a service technician.
Illegitimate Warranty Service Calls
Conditions under which a service call may be deemed illegitimate and incur charges.

Table of Contents