  • Page 1 FnIO G-Series Analog Output Module GT-4xxx User Manual Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 2 FnIO G-Series DOCUMENT CHANGE SUMMARY PAGE REMARKS DATE EDITOR 1.00 New Document 18/07/30 JY,Hyun 1.01 Add Product 19/01/16 JY,Hyun GT-4154, GT-4158, 1.02 Add Product 20/08/19 JY,Hyun GT-4214, GT-4254, GT-4218, GT-4258 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 3: Table Of Contents

    3.2.8. Parameter Data ......................20 3.3. GT-4118 ..........................21 3.3.1. Wiring Diagram ......................21 3.3.2. LED Indicator ......................22 3.3.3. Channel Status LED ....................22 3.3.4. Environment Specification ..................23 3.3.5. Specification ....................... 24 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 4 3.6.5. Specification ....................... 44 3.6.6. Data Value / Current ....................45 3.6.7. Mapping Data into the Image Table................46 3.6.8. Parameter Data ......................46 3.7. GT-4218 ..........................47 3.7.1. Wiring Diagram ......................47 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 5 4. Dimension ..........................61 4.1. GT-4xx4(RTB) ........................61 5. Mounting ..........................62 5.1. I/O Inserting and Removing Devices ................62 5.2. RTB (Removable Terminal Block) ................... 63 6. G-Bus Pin Description ......................64 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 6: Important Notes

    In no event will CREVIS be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
  • Page 7: Safety Instruction

    Avoid touching conductive components, GBUS Pin. 1.1.3. Certification c-UL-us UL Listed Industrial Control Equipment, certified for U.S. and Canada See UL File E235505 CE Certificate EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions Reach, RoHS (EU, CHINA) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 8: Analog Output Module List

    Analog Output 4 Channels, Current Output, 4~20mA, 12Bits 4214 GT-4254 Analog Output 4 Channels, Current Output, 4~20mA, 16Bits 4254 GT-4218 Analog Output 8 Channels, Current Output, 4~20mA, 12Bits 4218 GT-4258 Analog Output 8 Channels, Current Output, 4~20mA, 16Bits 4258 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 9: Specification

    Signal Description Signal Description Pin No. Analog Output Channel 0 Analog Output Channel 1 Analog Output Channel 2 Analog Output Channel 3 Output Channel Common(AGND) Output Channel Common(AGND) Output Channel Common(AGND) Output Channel Common(AGND) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 10: Led Indicator

    Green Output Channel 3 Green 3.1.3. Channel Status LED Status To indicate Normal Operation No Output Value Green Normal Operation Field Power Error All Channel Repeat Green and Off Field Power is unconnected. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 11: Environment Specification

    Based on IEC 60068-2-6 DNVGL-CG-0039 : Vibration Class B, 4g Industrial Emissions EN 61000-6-4/ All : 2011 Industrial Immunity EN 61000-6-2 : 2005 Installation Position Verical and horizontal installation is available Product Cerifications CE, UL, FCC Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 12: Specification

    - 40 ~ 70℃ temperature range specification can be guaranteed under the following conditions. - Load Resistance: Min 100Ω, Max 250Ω - Field Power Voltage Range: Max 26.4V - Otherwise, temperature specification can be guaranteed with -40 ~ 60℃ Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 13: Data Value / Current

    FnIO G-Series 3.1.6. Data Value / Current Current Range : 0~20mA Current 0.0mA 5.0mA 10.0mA 20.0mA Data(Hex) H0000 H03FF H07FF H0FFF Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 14: Parameter Data

    00 : Fault Value 01 : Hold last state 10 : Low Limit 11 : high Limit Byte 1 Not used Byte 2 Fault Value Low Byte Byte 3 Not used Fault Value high Byte Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 15: Gt-4154

    Signal Description Signal Description Pin No. Analog Output Channel 0 Analog Output Channel 1 Analog Output Channel 2 Analog Output Channel 3 Output Channel Common(AGND) Output Channel Common(AGND) Output Channel Common(AGND) Output Channel Common(AGND) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 16: Led Indicator

    Green Output Channel 3 Green 3.2.3. Channel Status LED Status To indicate Normal Operation No Output Value Green Normal Operation Field Power Error All Channel Repeat Green and Off Field Power is unconnected. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 17: Environment Specification

    Based on IEC 60068-2-6 DNVGL-CG-0039 : Vibration Class B, 4g Industrial Emissions EN 61000-6-4/ All : 2011 Industrial Immunity EN 61000-6-2 : 2005 Installation Position Verical and horizontal installation is available Product Cerifications CE, UL, FCC Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 18: Specification

    - 40 ~ 70℃ temperature range specification can be guaranteed under the following conditions. - Load Resistance: Min 100Ω, Max 250Ω - Field Power Voltage Range: Max 26.4V - Otherwise, temperature specification can be guaranteed with -40 ~ 60℃ Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 19: Data Value / Current

    FnIO G-Series 3.2.6. Data Value / Current Current Range : 0~20mA Current 0.0mA 5.0mA 10.0mA 20.0mA Data(Hex) H0000 H2000 H4000 H7FFF Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 20: Parameter Data

    00 : Fault Value 01 : Hold last state 10 : Low Limit 11 : high Limit Byte 1 Not used Byte 2 Fault Value Low Byte Byte 3 Fault Value high Byte Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 21: Gt-4118

    Analog Output Channel 1 Analog Output Channel 2 Analog Output Channel 3 Analog Output Channel 4 Analog Output Channel 5 Analog Output Channel 6 Analog Output Channel 7 Output Channel Common(AGND) Output Channel Common(AGND) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 22: Led Indicator

    Green 3.3.3. Channel Status LED Status To indicate Normal Operation No Output Channel Off No Output Output Channel Green Output Field Power Error All Channel Repeat Green and Off Field Power is unconnected. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 23: Environment Specification

    Based on IEC 60068-2-6 DNVGL-CG-0039 : Vibration Class B, 4g Industrial Emissions EN 61000-6-4/ All : 2011 Industrial Immunity EN 61000-6-2 : 2005 Installation Position Verical and horizontal installation is available Product Cerifications CE, UL, FCC Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 24: Specification

    Voltage Range : 18~30Vdc Power Dissipation : Max. 130mA @ 24Vdc Wiring I/O Cable Max. 2.0mm (AWG 14) Torque 0.8Nm(7lb-in) Weight Module Size 12mm x 99mm x 70mm Refer to ‘Environment Specification' Environment Condition Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 25: Data Value / Current

    FnIO G-Series 3.3.6. Data Value / Current Current Range : 0~20mA Current 0.0mA 5.0mA 10.0mA 20.0mA Data(Hex) H0000 H2000 H4000 H7FFF Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 26: Mapping Data Into The Image Table

    Analog Output Ch7 High byte -. Output Module Data - 16byte Output Data Analog Input Ch0 Analog Input Ch1 Analog Input Ch2 Analog Input Ch3 Analog Input Ch4 Analog Input Ch5 Analog Input Ch6 Analog Input Ch7 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 27: Parameter Data

    Byte 1 00 : Fault Value 01 : Hold last state 10 : Low Limit 11 : high Limit Byte 2 Fault Value Low Byte Byte 3 Not used Fault Value high Byte Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 28: Gt-4158

    Analog Output Channel 1 Analog Output Channel 2 Analog Output Channel 3 Analog Output Channel 4 Analog Output Channel 5 Analog Output Channel 6 Analog Output Channel 7 Output Channel Common(AGND) Output Channel Common(AGND) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 29: Led Indicator

    Green 3.4.3. Channel Status LED Status To indicate Normal Operation No Output Channel Off No Output Output Channel Green Output Field Power Error All Channel Repeat Green and Off Field Power is unconnected. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 30: Environment Specification

    DNVGL-CG-0039 : 2016 /6 Vibration Class B, 4g Industrial Emissions EN 61000-6-4/ All : 2011 Industrial Immunity EN 61000-6-2 : 2005 Installation Position Verical and horizontal installation is available Product Cerifications CE, UL, FCC Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 31: Specification

    Voltage Range : 18~30Vdc Power Dissipation : Max. 80mA @ 24Vdc Wiring I/O Cable Max. 2.0mm (AWG 14) Torque 0.8Nm(7lb-in) Weight Module Size 12mm x 99mm x 70mm Refer to ‘Environment Specification' Environment Condition Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 32: Data Value / Current

    FnIO G-Series 3.4.6. Data Value / Current Current Range : 0~20mA Current 0.0mA 5.0mA 10.0mA 20.0mA Data(Hex) H0000 H2000 H4000 H7FFF Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 33: Mapping Data Into The Image Table

    Analog Output Ch7 High byte -. Output Module Data - 16byte Output Data Analog Input Ch0 Analog Input Ch1 Analog Input Ch2 Analog Input Ch3 Analog Input Ch4 Analog Input Ch5 Analog Input Ch6 Analog Input Ch7 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 34: Parameter Data

    Channel 4 Byte 1 00 : Fault Value 01 : Hold last state 10 : Low Limit 11 : high Limit Byte 2 Fault Value Low Byte Byte 3 Fault Value high Byte Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 35: Gt-4214

    Signal Description Signal Description Pin No. Analog Output Channel 0 Analog Output Channel 1 Analog Output Channel 2 Analog Output Channel 3 Output Channel Common(AGND) Output Channel Common(AGND) Output Channel Common(AGND) Output Channel Common(AGND) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 36: Led Indicator

    Output Channel 2 Green Output Channel 3 Green 3.5.3. Channel Status LED Status To indicate Normal Operation Green Normal Operation Field Power Error All Channel Repeat Green and Off Field Power is unconnected. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 37: Environment Specification

    Based on IEC 60068-2-6 DNVGL-CG-0039 : Vibration Class B, 4g Industrial Emissions EN 61000-6-4/ All : 2011 Industrial Immunity EN 61000-6-2 : 2005 Installation Position Verical and horizontal installation is available Product Cerifications CE, UL, FCC Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 38: Specification

    - 40 ~ 70℃ temperature range specification can be guaranteed under the following conditions. - Load Resistance: Min 100Ω, Max 250Ω - Field Power Voltage Range: Max 26.4V - Otherwise, temperature specification can be guaranteed with -40 ~ 60℃ Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 39: Data Value / Current

    FnIO G-Series 3.5.6. Data Value / Current Current Range : 4~20mA Current 4.0mA 8.0mA 12.0mA 20.0mA Data(Hex) H0000 H0400 H0800 H0FFF Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 40: Mapping Data Into The Image Table

    00 : Fault Value 01 : Hold last state 10 : Low Limit 11 : high Limit Byte 1 Not used Byte 2 Fault Value Low Byte Byte 3 Not used Fault Value high Byte Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 41: Gt-4254

    Signal Description Signal Description Pin No. Analog Output Channel 0 Analog Output Channel 1 Analog Output Channel 2 Analog Output Channel 3 Output Channel Common(AGND) Output Channel Common(AGND) Output Channel Common(AGND) Output Channel Common(AGND) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 42: Led Indicator

    Output Channel 2 Green Output Channel 3 Green 3.6.3. Channel Status LED Status To indicate Normal Operation Green Normal Operation Field Power Error All Channel Repeat Green and Off Field Power is unconnected. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 43: Environment Specification

    Based on IEC 60068-2-6 DNVGL-CG-0039 : Vibration Class B, 4g Industrial Emissions EN 61000-6-4/ All : 2011 Industrial Immunity EN 61000-6-2 : 2005 Installation Position Verical and horizontal installation is available Product Cerifications CE, UL, FCC Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 44: Specification

    - 40 ~ 70℃ temperature range specification can be guaranteed under the following conditions. - Load Resistance: Min 100Ω, Max 250Ω - Field Power Voltage Range: Max 26.4V - Otherwise, temperature specification can be guaranteed with -40 ~ 60℃ Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 45: Data Value / Current

    FnIO G-Series 3.6.6. Data Value / Current Current Range : 4~20mA Current 4.0mA 8.0mA 12.0mA 20.0mA Data(Hex) H0000 H2000 H4000 H7FFF Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 46: Mapping Data Into The Image Table

    00 : Fault Value 01 : Hold last state 10 : Low Limit 11 : high Limit Byte 1 Not used Byte 2 Fault Value Low Byte Byte 3 Fault Value high Byte Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 47: Gt-4218

    Analog Output Channel 1 Analog Output Channel 2 Analog Output Channel 3 Analog Output Channel 4 Analog Output Channel 5 Analog Output Channel 6 Analog Output Channel 7 Output Channel Common(AGND) Output Channel Common(AGND) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 48 Output Channel 6 Green Output Channel 7 Green 3.7.3. Channel Status LED Status To indicate Normal Operation Green Normal Operation Field Power Error All Channel Repeat Green and Off Field Power is unconnected. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 49 Based on IEC 60068-2-6 DNVGL-CG-0039 : Vibration Class B, 4g Industrial Emissions EN 61000-6-4/ All : 2011 Industrial Immunity EN 61000-6-2 : 2005 Installation Position Verical and horizontal installation is available Product Cerifications CE, UL, FCC Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 50 Voltage Range : 18~30Vdc Power Dissipation : Max. 130mA @ 24Vdc Wiring I/O Cable Max. 2.0mm (AWG 14) Torque 0.8Nm(7lb-in) Weight Module Size 12mm x 99mm x 70mm Refer to ‘Environment Specification' Environment Condition Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 51 FnIO G-Series 3.7.6. Data Value / Current Current Range : 4~20mA Current 4.0mA 8.0mA 12.0mA 20.0mA Data(Hex) H0000 H0400 H0800 H0FFF Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 52 Analog Output Ch7 High byte -. Output Module Data - 16byte Output Data Analog Input Ch0 Analog Input Ch1 Analog Input Ch2 Analog Input Ch3 Analog Input Ch4 Analog Input Ch5 Analog Input Ch6 Analog Input Ch7 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 53 Byte 1 00 : Fault Value 01 : Hold last state 10 : Low Limit 11 : high Limit Byte 2 Fault Value Low Byte Byte 3 Not used Fault Value high Byte Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 54 Analog Output Channel 1 Analog Output Channel 2 Analog Output Channel 3 Analog Output Channel 4 Analog Output Channel 5 Analog Output Channel 6 Analog Output Channel 7 Output Channel Common(AGND) Output Channel Common(AGND) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 55 Output Channel 6 Green Output Channel 7 Green 3.8.3. Channel Status LED Status To indicate Normal Operation Green Normal Operation Field Power Error All Channel Repeat Green and Off Field Power is unconnected. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 56 Based on IEC 60068-2-6 DNVGL-CG-0039 : Vibration Class B, 4g Industrial Emissions EN 61000-6-4/ All : 2011 Industrial Immunity EN 61000-6-2 : 2005 Installation Position Verical and horizontal installation is available Product Cerifications CE, UL, FCC Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 57 Voltage Range : 18~30Vdc Power Dissipation : Max. 85mA @ 24Vdc Wiring I/O Cable Max. 2.0mm (AWG 14) Torque 0.8Nm(7lb-in) Weight Module Size 12mm x 99mm x 70mm Refer to ‘Environment Specification' Environment Condition Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 58 FnIO G-Series 3.8.6. Data Value / Current Current Range : 4~20mA Current 4.0mA 8.0mA 12.0mA 20.0mA Data(Hex) H0000 H2000 H4000 H7FFF Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 59 Analog Output Ch7 High byte -. Output Module Data - 8byte Output Data Analog Input Ch0 Analog Input Ch1 Analog Input Ch2 Analog Input Ch3 Analog Input Ch4 Analog Input Ch5 Analog Input Ch6 Analog Input Ch7 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 60 Channel 4 Byte 1 00 : Fault Value 01 : Hold last state 10 : Low Limit 11 : high Limit Byte 2 Fault Value Low Byte Byte 3 Fault Value high Byte Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 61: Dimension

    FnIO G-Series 4. Dimension 4.1 GT-4xx4, GT-4xx8 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 62: Mounting

    - As above figure in order to safeguard the G-Series module from jamming, it should be fixed onto the DIN rail with locking level. To do so, fold on the upper of the locking lever. To pull out the G-Series module, unfold the locking lever as below figure. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 63: Rtb (Removable Terminal Block)

    There is a locking switch on the RTB for the easy combination and easy removal. " Easy combination and easy removal for IO modules on the din rail through One Touch Locking Switch. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...
  • Page 64: G-Bus Pin Description

    GBUS TX - GBUS RX + GBUS RX - Field Power (GND) Field Power (VCC) Do not touch data and field power pins in order to avoid soiling and damage by ESD noise. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL: www.crevis.co.kr...