4. Choose the fabric on which to change the duplicate domain ID; connect to the conflicting
5. Enter the switchDisable command.
6. Enter the configure command.
7.
8. When the Domain prompt displays, type in the new number.
9. Press enter on all prompts to accept their default settings.
10. Enter the switchEnable command.
11. Repeat
Example of setting the domain ID
WARNING: The domain ID will be changed. The port level zoning may be affected
Fabric OS Troubleshooting and Diagnostics Guide
53-1001769-01
switch in that fabric.
When the Fabric Parameters prompt displays, type y.
This will enable the joining switch to obtain a new domain ID as part of the process of coming
online. The fabric principal switch will allocate the next available domain ID to the new switch
during this process.
step 4
through
step 10
switch_89:FID89:admin> switchdisable
switch_89:FID89:admin> configure
Configure...
Fabric parameters (yes, y, no, n): [no] y
Domain: (1..239) [1] 89
WWN Based persistent PID (yes, y, no, n): [no]
Allow XISL Use (yes, y, no, n): [yes]
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000]
WAN_TOV: (0..30000) [0]
MAX_HOPS: (7..19) [7]
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0]
Disable Device Probing: (0..1) [0]
Suppress Class F Traffic: (0..1) [0]
Per-frame Route Priority: (0..1) [0]
Long Distance Fabric: (0..1) [0]
BB credit: (1..27) [16]
Disable FID Check (yes, y, no, n): [no]
Insistent Domain ID Mode (yes, y, no, n): [no]
Virtual Channel parameters (yes, y, no, n): [no]
F-Port login parameters (yes, y, no, n): [no]
Zoning Operation parameters (yes, y, no, n): [no]
RSCN Transmission Mode (yes, y, no, n): [no]
Arbitrated Loop parameters (yes, y, no, n): [no]
System services (yes, y, no, n): [no]
Portlog events enable (yes, y, no, n): [no]
ssl attributes (yes, y, no, n): [no]
rpcd attributes (yes, y, no, n): [no]
webtools attributes (yes, y, no, n): [no]
if additional switches have conflicting domain IDs.