Checking For A Loop Initialization Failure; Checking For A Point-To-Point Initialization Failure - Brocade Communications Systems 8 Troubleshooting And Diagnostics Manual

Fabric os troubleshooting and diagnostics guide
Hide thumbs Also See for 8:
Table of Contents

Advertisement

Checking for a loop initialization failure

1. Verify the port is an L_Port.
2. Verify that loop initialization occurred if the port to which the loop device is attached does not
3. Skip point-to-point initialization by using the portCfgLport Command.

Checking for a point-to-point initialization failure

1. Enter the switchShow command to confirm that the port is active and has a module that is
2. Enter the portLogShow or portLogDump commands.
3. Verify the event area for the port state entry is pstate. The command entry AC indicates that
4. Skip over the loop initialization phase.
Fabric OS Troubleshooting and Diagnostics Guide
53-1001769-01
a. Enter the switchShow command.
b. Check the last field of the output to verify that the switch port indicates an L_Port. If a loop
device is connected to the switch, the switch port must be initialized as an L_Port.
c.
Check to ensure that the state is online; otherwise, check for link failures.
Example of an online L_Port
Area Port Media Speed State
=====================================
(output truncated)
66
66
--
N8
No_Module
67
67
id
AN
No_Sync
68
68
id
N2
Online
negotiate as an L_Port.
a. Enter the portLogShow or portLogDump command to display the port log for all ports on
the switch; or if you are looking for a specific port, enter the portLogDumpPort command.
b. Check argument number four for the loop initialization soft assigned (LISA) frame
0x11050100.
switch:admin> portlogdumpport 4
time
task
-----------------------------------------------------------------
11:40:02.078
PORT
Received LISA frame
The LISA frame indicates that the loop initialization is complete.
The switch changes to point-to-point initialization after the LISA phase of the loop initialization.
This behavior sometimes causes trouble with old HBAs.
synchronized.
If a fabric device or another switch is connected to the switch, the switch port must be online.
the port has completed point-to-point initialization.
switch:admin> portlogdumpport 4
time
task
-------------------------------------------------
11:38:21.726
INTR
Proto
L-Port
event
port
cmd
Rx3
23
20
event
port cmd
args
pstate
4
AC
Link failures
13 public
args
22000000,00000000,ffffffff,11050100
3
29

Advertisement

Table of Contents
loading