Binder KBF-LQC 720 Operating Manual

Binder KBF-LQC 720 Operating Manual

For constant conditions with program control with ich compliant illumination and light quantum control and adjustable light cassettes
Table of Contents

Advertisement

Quick Links

Operating Manual
APT.line™ KBF-LQC (E5.2)
Climatic chamber for constant conditions
with program control
with ICH compliant illumination and Light Quantum Control
and adjustable light cassettes
Model
KBF-LQC 240 (E5.2)
KBF-LQC 240-UL (E5.2)
KBF-LQC 720 (E5.2)
KBF-LQC 720-UL (E5.2)
BINDER GmbH
Address
Tel.
Fax
Internet
E-mail
Service Hotline
Service Fax
Service E-Mail
Service Hotline USA
Service Hotline Spain
Service Hotline Asia Pacific
Service Hotline Russia and CIS +7 495 98815 17
Issue 12/2010
Art. No.
9020-0177, 9120-0177
9020-0161, 9120-0161
9020-0171, 9120-0171
9020-0170, 9120-0170
Post office box 102
D-78502 Tuttlingen
+49 7462 2005 0
+49 7462 2005 100
http://www.binder-world.com
info@binder-world.com
+49 7462 2005 555
+49 7462 2005 93 555
service@binder-world.com
+1 866 885 9794 or +1 631 224 4340
+34 9492 677 23
+852 39070500 or +852 39070503
Art. No. 7001-0178

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KBF-LQC 720 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Safety
Legal Considerations
Information regarding legal aspects and disclaimers for the operating manual.
Structure of the Safety Instructions
Explanation of safety definitions, symbols, and signal word panels used in the manual.
Localization and Position of Safety Labels
Details the placement of warning and safety labels on the unit.
Type Plate Information
Information and explanation of the data presented on the unit's type plate.
General Safety Instructions for Installation and Operation
Essential safety guidelines for installation, operation, and general precautions.
Intended Use
Defines the proper and intended applications and limitations for the climatic chamber.
Humidity Sensor Resistance to Harmful Substances
Lists substances affecting the humidity sensor and their tolerance limits.
Unit Description
Unit Overview
Provides a general overview and identifies key components of the climatic chamber.
Instrument Panel for KBF-LQC
Describes the functions and components of the unit's main instrument panel.
Lateral Control Panel, Right Side
Details the controls and connections on the right-side lateral panel.
Lateral Control Panel, Left Side
Details the controls and connections on the left-side lateral panel.
Completeness of Delivery, Transportation, Storage, and Installation
Unpacking and Checking Delivery
Instructions for unpacking, inspecting the unit, and checking for damages.
Guidelines for Safe Lifting and Transportation
Procedures and precautions for safely moving and transporting the unit.
Storage Guidelines
Guidelines for proper intermediate storage of the unit.
Location of Installation and Ambient Conditions
Recommendations for optimal installation site and environmental conditions.
Installation and Connections
Spacers for Rear Wall Distance
Instructions for attaching rear wall distance spacers for proper ventilation.
Wastewater Connection
Details on how to connect the wastewater outlet hose.
Freshwater Supply
Information and methods for supplying freshwater to the unit.
Electrical Connection
Instructions for connecting the unit to the power supply, including voltage checks.
Installation and Connection of Light Cassettes
Guidance on installing and connecting the light cassettes within the chamber.
Connecting the Light Sensors
Instructions for connecting light sensors to measure illumination and UV intensity.
Start Up
Function Overview of MB1 Display Program Controller
Introduction to the MB1 controller's functions and display elements.
Operating Modes
Description of the three operating modes: Idle, Manual, and Program Mode.
Performance After Power Failures
How the unit behaves and recovers after a power interruption.
Turning On the Unit
Step-by-step guide for powering on the climatic chamber.
Settings of the Controller MB1
Selection of the Menu Language
Procedure for selecting the user interface language on the MB1 controller.
Function Overview of Program Controller MB1 Displays
Detailed explanation of the different display screens and their information.
Menu Settings in the User-settings Menu
Configuration options available within the 'User-settings' menu.
Menu Settings in the User Level Menu
Settings accessible via the 'User Level' menu, including password protection.
Graphic Representation of Historical Measurement (Chart Recorder Function)
Setting the Storage Rate
Procedure for configuring the data storage rate for the chart recorder.
Manual Mode
Entering the Set Point Values
How to input desired temperature, humidity, and fan speed set points.
Entering Set Point Values Without Illumination
Specific set point entries for temperature and humidity without illumination.
Performance After Power Failure in Manual Mode
Behavior of the unit after a power failure while in Manual Mode.
Function of Light Measurement and Integration: Light Quantum Control
Illumination Measurement and Temporal Integration
Explanation of how illumination and UV intensity are measured and integrated.
Toggling Between Actual and Integrated Values
How to switch between viewing current and integrated light values.
Program Operation of Temperature and Humidity Controller
Overview of Menu-Based Program Entry
Introduction to creating programs using the menu interface.
Entry of Temperature Values and Fan Speed
Detailed steps for programming temperature and fan speed profiles.
Entry of Humidity Values
Detailed steps for programming humidity profiles.
Selecting Between Set-Point Ramp and Set-Point Step
Understanding and selecting different transition types for set points.
Program Entry as Set-Point Ramp or Set-Point Step
Examples of creating programs using ramps and steps.
Advice for Programming Temperature/Humidity Transitions
Tips and considerations for programming complex temperature/humidity changes.
Repetition of Program Sections
How to set up program sections for repetition.
Performance After Power Failure in Program Mode
Behavior after power failure while operating in Program Mode.
Starting a Previously Entered Program
Procedure for loading and running a saved program.
Deleting a Program
Instructions for removing saved programs from the controller.
Template for Temperature Profile
Template for planning and documenting temperature profiles.
Template for Humidity Profile
Template for planning and documenting humidity profiles.
Program Table Template for Temperature and Fan Speed
Template for entering temperature and fan speed program data.
Program Table Template for Humidity
Template for entering humidity program data.
Temperature Safety Devices
Over Temperature Protective Device (Class 1)
Description of the primary over-temperature protection device.
Safety Controller (Temperature Safety Device Class 3.1)
Details on the secondary, independent temperature safety controller.
Temperature Safety Device Class 3.3 (DIN 12880) (Option)
Information on the optional over/under temperature safety device class 3.3.
Notification and Alarm Functions
Notification and Alarm System Overview (Auto Diagnosis System)
Overview of the unit's notification and alarm system, including error messages.
Resetting Notification or Alarm Messages
Procedure for acknowledging and clearing notification or alarm messages.
Humidity System
Function of Humidifying and Dehumidifying System
Explanation of how the humidification and dehumidification systems operate.
ICH Compliant Illumination According to CPMP/ICH/279/95 (Q1B)
BINDER ICH Light
Description of the BINDER ICH light system for photostability testing.
Adjustable Light Cassettes
Information on the adjustable light cassettes and their placement.
Characteristic Features of Light Sensors
LUX Sensor
Features and operation of the LUX light sensor.
UVA Sensor
Features and operation of the UVA light sensor.
Spectral Range
Details on the spectral sensitivities of the light sensors.
Spatial Sensitivity
Explanation of the spatial sensitivity of the spherical light sensors.
Options
Communication Software APT-COM™ 3 DataControlSystem (Option)
Details on the APT-COM™ 3 software for chamber control and data management.
Interface RS 422 (Option)
Description of the optional RS422 serial interface.
Data Logger Kits
Information on BINDER Data Logger kits for temperature and humidity monitoring.
Analog Outputs for Temperature and Humidity (Option)
Details on analog outputs for transmitting temperature and humidity data.
Zero-Voltage Relay Alarm Outputs for Alarm Transmission (Option)
Description of relay outputs for central alarm transmission.
Water Protected Internal Socket (Option – Not for UL Units)
Information about the splash-proof internal socket option.
Keyboard Locking (Available via BINDER Individual)
How to lock and unlock the controller keyboard.
Additional Flexible Pt 100 Temperature Sensor (Option)
Details on the optional flexible Pt100 temperature sensor.
External Freshwater and Waste-Water Cans (Option)
Information on optional external water cans for freshwater and wastewater.
BINDER Pure Aqua Service (Option)
Details on the optional BINDER Pure Aqua Service water treatment system.
Maintenance, Cleaning, and Service
Maintenance Intervals and Service
Recommendations for regular maintenance, cleaning, and service schedules.
Replacement of Fluorescent Tubes
Procedure for replacing fluorescent tubes in the light cassettes.
Calibrating Light Sensors and Adjusting Controller Display
Steps for calibrating light sensors and adjusting the controller display.
Cleaning and Decontamination
Guidelines for cleaning the chamber and decontaminating it.
Sending the Unit Back to BINDER GmbH
Procedure and requirements for returning the unit for repair or service.
Disposal
Disposal of Transport Packing
Guidance on how to dispose of the unit's transport packaging materials.
Decommissioning
Steps for safely decommissioning the unit before disposal or long-term storage.
Disposal in the Federal Republic of Germany
Specific disposal instructions for Germany according to WEEE directive.
Disposal in EC Member States (Excluding Germany)
Disposal instructions for EC member states excluding Germany.
Disposal in Non-Member States of the EC
Disposal guidelines for countries outside the EC.
Technical Description
Factory Calibration and Adjustment
Information about factory calibration and adjustment procedures.
Over Current Protection
Details on the unit's over-current protection mechanisms.
Definition of Usable Volume
Explanation and calculation of the chamber's usable internal volume.
KBF-LQC Technical Data
Comprehensive technical specifications and data for the KBF-LQC unit.
Equipment and Options KBF-LQC
List of standard equipment and available optional accessories for the KBF-LQC.
Spare Parts
List of available spare parts and their corresponding article numbers.

Table of Contents