Siemens 6GT2821-4AC40 Operating Manual

Siemens 6GT2821-4AC40 Operating Manual

Ascii protocol

Advertisement

SIMATIC Ident
RFID systems
ASCII protocol for RF200
Operating Manual
11/2016
C79000-G8976-C329-04
___________________
Introduction
Command and message
___________________
frames
___________________
Scan mode function
extension for ASCII readers
___________________
Reader
___________________
Transponder
___________________
Appendix
___________________
Service & Support
1
2
3
4
5
A
B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6GT2821-4AC40 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction to SIMATIC RF200 ASCII Protocol
Purpose of the Operating Manual
Describes the communications procedure of SIMATIC RF200 readers with the ASCII protocol.
Target Audience for RF200 Manual
Intended for application developers operating the RFID system "RF200" on controllers or host systems.
Registered Trademarks of Siemens
Lists registered trademarks such as SIMATIC, SIMATIC NET, SIMATIC RF, and MOBY.
Additional Information and Resources
Provides a link to the "RF200 system manual" for further details and resources.
Manual Revision History
Lists previous editions of the operating manual with their respective remarks and changes.
Protocol Properties and Settings
Details serial interface settings (data frame, stop bit, parity, speed) and frame structure (STX, ETX, LF).
Configurable Interface Parameters
Lists selectable parameters like transmission speed, parity, and stop bits, and how to modify them.
Data Transmission Specifications
Explains data transfer format (high/low nibble) and command chaining rules for data transmission.
SIMATIC RF200 Command and Message Frames
Overview of Supported ASCII Commands
Lists supported ASCII commands such as READ, WRITE, SLG-STATUS, SET-ANT, RESET, and ANW-MELD.
READ Command Details
Details the structure and acknowledgment of the "READ" command for transponder data retrieval.
WRITE Command Details
Details the structure and acknowledgment of the "WRITE" command for transponder data storage.
SLG STATUS (Mode 0) Command
Details the structure and acknowledgment of the SLG STATUS command for mode 0.
SLG STATUS (Mode 1) Command
Details the structure and acknowledgment of the SLG STATUS command for mode 1.
MDS-STATUS (Mode 3) Command
Details the structure and acknowledgment of the MDS-STATUS command for mode 3.
SET-ANT Command Acknowledgment
Details the acknowledgment for the SET-ANT command, indicating antenna status.
SET-RS232 Command for Interface Configuration
Details the SET-RS232 command used for configuring serial interface parameters.
RESET Command for Reader Initialization
Details the RESET command for reader initialization and clearing errors.
ANW-MELD Message for Presence Alarms
Details the ANW-MELD message for reporting asynchronous presence alarms.
RF200 Reader Error Messages
Lists error codes recognized by the RF200 system and their corresponding descriptions.
Scan Mode Functionality for ASCII Readers
Enabling and Disabling Scan Mode
Details the SYSTEM command for enabling scan mode and the "Change parameters" frame for disabling it.
Scan Mode Communication and Parameter Setup
Describes data transfer in scan mode and functions like changing parameters and reading status.
Communication Protocol in Scan Mode
Details interface parameters (RS232) and frame structures for scan mode communication.
Scan Mode Parameter Data Description
Lists and describes all parameters available in the reader for scan mode configuration.
Changing Parameters Frame Configuration
Explains how to change parameters (serial interface, scan mode) retentively or non-retentively.
Reading Reader Status with "Read Status" Frame
Describes the frame used to read reader status, parameters, and version information.
Enabling Test Mode with "Enable Test Mode" Frame
Explains the frame for enabling test mode, which continuously scans for transponders.
Scan Mode Error Message Reference
Lists error codes and descriptions relevant to scan mode and parameter settings.
SIMATIC RF200 Reader Overview
Reader Ordering Data and Article Numbers
Lists article numbers for different SIMATIC RF200 reader models with RS-232 interface.
Reader LED Status Indicator Guide
Explains the meaning of different LED colors and flashing patterns on the reader.
SIMATIC Transponder Selection and Configuration
ISO Transponder Selection Guide
Lists various ISO transponder types (MDS D100-D160) with specifications and article numbers.
Transponder Memory Configuration Details
Details the memory layout and configuration for different transponder types.
Appendix: Additional Information
PC Driver LAUF/3964R for Configuration
Describes the use of the "LAUF/3964R" driver for parameter assignment and communication.
Connecting Cables and Wiring Diagrams
Details the connecting cable with a 4-pin power supply connector and its wiring diagram.
Wide-Range Power Supply Unit Specifications
Describes the wide-range power supply unit, its characteristics, and ordering data.
Siemens Service and Support Resources
Siemens Industry Online Support Portal
Provides access to documentation, FAQs, downloads, and technical support queries.
Siemens RFID Technology Homepage
Provides general information on Siemens identification systems and RFID technology.
Online Catalog and Ordering System
Links to the Siemens Industry Mall for online product catalog and ordering.
SITRAIN - Industrial Training Programs
Information on Siemens training courses for industry professionals and their curriculum.

Table of Contents