Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Vanderbilt Manuals
Security Sensors
GM760
Application manual
Vanderbilt GM760 Application Manual
Seismic detectors and accessories
Hide thumbs
Also See for GM760
:
Technical support information
(4 pages)
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
page
of
66
Go
/
66
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
1 General Information
Detector and Accessory Overview
2 Applications
Detector Applications and Attack Profiles
Detector Selection
Steel Applications and Accessory Options
Concrete Applications and Accessory Options
3 Installation - Detectors
Drill Template
Installation Methods
Detector Installation Onto Flat Steel Surface
Detector Installation on Steel Using the GMXP0 Mounting Plate
Weld Fixing
Screw Fixing
Glue Fixing
Indirect Installation on Concrete
4 Installation - Accessories
GMXP0 Mounting Plate
GMXS1 Internal Test Transmitter
GMXS5 - External Test Transmitter
GMXW0 Wall Mounting Kit
GMXB0 Floor Box
GMXP3 & GMXP3Z Lock Protection System
GMAS6 Movable Mounting Kit
Gmxd7
GMSW7 Senstool Software
GMXC2 Conduit Connection Cover
GMXS4 Seismic Test Tool
5 Planning
General Application
General Planning Guidelines
Planning Limitations
Installation Guidelines
Detector Requirements
System Requirements
6 Design
General Principles
Seismic Calculation Tool
Manual Calculation
Calculating the Number and Location of the Detectors
Manually Adjusting the Detector Locations
Wall Height and Operating Radius
Modular Vaults
Interlocking Panels
Panels with Steel Surrounds
Vault Protection Guidelines
Night Deposit Box and ATM Applications
Night Deposit Boxes
Atm's
General Design Guide for Night Safes & Atms
Detector Sensitivity
Cabinet Protection
Document Cabinet
Filing Cabinet
Gun Cabinet
7 Commissioning
Pre-Commissioning Checklist
Commissioning & Test Options
Staged Commissioning
Staged Commissioning Procedure
8 Senstool
Senstool GMXS7
Senstool User Mode Settings (Recommended)
Setting up Senstool
Recording Ambient Noise Levels
Trouble Shooting
Using Senstool as a Record of Commissioning
9 Interface to SPC Panel/System
General Electrical Connections
Testing the Detectors
Manual Test
Automatic Test
Automatic Test When Setting
Test and Indication Flow
User Interface
10 Useful Information
Cross-Reference Chart for Country-Specific Approvals
Cross Reference Chart for All Related Internal Documentation
Cross Reference Chart for Applicable, External Related Documents
Cross Reference List of All Part Numbers
Graphic Index
11 Appendix 1: Drill Template Gm7Xx
12 Appendix 2: Drill Template GMXP3/Z
13 Appendix 3: Drill Template GMXS5
Advertisement
Quick Links
1
Detector and Accessory Overview
2
Detector Applications and Attack Profiles
3
Detector Selection
4
Installation Methods
5
Detector Sensitivity
Download this manual
GM7xx
Seismic Detectors and Accessories
Application Guide
Document No.: I-200153-1
Edition: 08.2016
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the GM760 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Vanderbilt GM760
Security Sensors Vanderbilt Seismic GM760 Technical Support Information
(4 pages)
Security Sensors Vanderbilt GM730 Installation Manual
Seismic detector (21 pages)
Security Sensors Vanderbilt GM7 Series Application Manual
Seismic detectors and accessories (66 pages)
Security Sensors Vanderbilt GM730 User Manual
Vibration detector (6 pages)
Security Sensors Vanderbilt GM775 Installation Manual
Seismic detector (12 pages)
Security Sensors Vanderbilt GM710 Installation Manual
Seismic detector (12 pages)
Security Sensors Vanderbilt GM775LSNi Installation Manual
Seismic detector (11 pages)
Security Sensors Vanderbilt Intrunet E-Line ADM-I12W1 Quick Start Manual
Wireless pir detector (10 pages)
Security Sensors Vanderbilt IS443 Installation Manual
Infrared barrier (22 pages)
Security Sensors Vanderbilt bright blue Manual
(242 pages)
Vanderbilt PDM-I12T, PDM-I18T - Motion Detector Installation Instructions
(article)
Security Sensors Vanderbilt AGB800 Instruction And Installation Manual
Acoustic glass break detector (4 pages)
Security Sensors Vanderbilt AGB800-AM Instruction And Installation Manual
Acoustic glass break detector with antimasking (4 pages)
Security Sensors Vanderbilt IR261 Installation Manual
Passive infrared detector (8 pages)
Security Sensors Vanderbilt ES 470 Installation Manual
Shock and vibration detector (2 pages)
Security Sensors Vanderbilt WPIR-EXT Installation Instructions & User Manual
Two way wireless outdoor double pir detector with anti-masking (15 pages)
Summarization of Contents
General Information
Detector and Accessory Overview
Describes the GM7xx range, its detection methods, sensor technology, and compatibility.
Applications
Detector Applications and Attack Profiles
Lists common applications for seismic detectors and the corresponding attack types.
Steel and Concrete Installation Options
Detector Installation Procedures
Drill Template Usage
Provides guidance on using the drill template for correct detector placement.
Installation Methods
Outlines the main methods for installing seismic detectors.
Flat Steel Surface Installation
Details the process for mounting detectors directly onto flat steel surfaces.
Steel Installation with GMXP0 Mounting Plate
Weld Fixing
Describes the procedure for securely welding the GMXP0 mounting plate to a steel surface.
Screw Fixing for GMXP0 Plate
Glue Fixing for GMXP0 Plate
Indirect Installation on Concrete
Installation - Accessories
GMXP0 Mounting Plate
Describes the GMXP0 plate used for secure detector mounting on various surfaces.
GMXS1 Internal Test Transmitter
Explains the GMXS1 for testing detector functionality via a switched input.
GMXS5 External Test Transmitter
GMXW0 Wall Mounting Kit
GMXB0 Floor Box
Lock Protection Systems
GMAS6 Movable Mounting Kit
GMXD7 Drilling Protection
GMSW7 SensTool Software
GMXC2 Conduit Cover & GMXS4 Test Tool
Planning and Guidelines
General Application and Guidelines
Emphasizes correct planning for optimal detector performance and provides installation guidelines.
Planning Limitations and Requirements
Planning Limitations
Highlights precautions required for reliable detection and immunity to unwanted alarms.
Installation Guidelines & Requirements
Outlines detector and system requirements for optimal setup and coverage.
Design Principles
General Principles for Detector Placement
Discusses detector spacing and coverage to ensure optimal security and system performance.
Seismic Calculation and Manual Planning
Calculating Detector Number and Location
Explains manual methods for determining detector placement and quantity.
Manually Balancing Detector Locations
Wall Height, Vaults, and Coverage
Modular Vaults - Interlocking Panels
Modular Vaults - Panels with Steel Surrounds
Vault Protection Guidelines
Night Deposit Box and ATM Applications
Night Deposit Boxes
Details detector placement considerations for night deposit boxes.
ATMs and General Design Guide
Detector Sensitivity Adjustment
Cabinet Protection
Commissioning Procedures
Pre-commissioning Checklist
Lists essential tasks and checks before detector installation.
Commissioning & Test Options
Outlines various methods for testing detector functionality.
Staged Commissioning
Staged Commissioning Procedure
Details step-by-step detector commissioning using a multi-meter.
SensTool Configuration and Setup
SensTool GMXS7 Overview
Introduces SensTool for GM7xx detector configuration and monitoring.
Setting Up SensTool
Guides on establishing communication and configuring the software.
Recording Ambient Noise Levels
Trouble Shooting
Using SensTool for Commissioning Records
Interface to SPC Panel/System
General Electrical Connections
Discusses wiring options and end-of-line monitoring for SPC system integration.
Testing the Detectors
Manual and Automatic Test Procedures
Describes manual, automatic, and set-time tests for seismic detectors.
Automatic Test When Setting
Test Flow and User Interface
Useful Information
Country-Specific Approvals
Lists specific approvals for seismic detectors in different countries.
Documentation Cross-References
Graphic Index
Table Index
Appendix 1: GM7xx Drill Template
Appendix 2: GMXP3/Z Drill Template
Appendix 3: GMXS5 Drill Template
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the GM760 and is the answer not in the manual?
Questions and answers