Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
WAREMA Manuals
Weather Station
Wisotronic 3
Installation instructions manual
WAREMA Wisotronic 3 Installation Instructions Manual
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
page
of
128
Go
/
128
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
1 Legal Notes
2 Safety Instructions
Meanings of Symbols and Pictographs
Intended Use
Target Group
General Safety Instructions
Working Safely
Retrofitting and Modifications
Additional Documents
Basic Software Versions
3 Introduction
Operating Elements
Principal Structure of a Wisotronic System
Concept
Channels, Facades and Products
Groups
Scenes
4 Sensor
Weather Station Multisense
Sensor Wind/Photo/Radio Clock
Sensor Photo/Radio Clock
Sensor Photo (180°)
Sensor
Outside Temperature
Sensor Inside Temperature
5 Installation
Scope of Delivery
Options
Sensor
Further Options
Procedure
Mounting the Power Unit
REG Variant
Surface-Mounted Variant
Flush-Mounted Variant
Installing the Control Panel
Flush-Mounting
Suface-Mounting
Mounting in Pattress Box
Mounting the Control Panel
6 Connection
Connection Information
Terminals
Power Unit Screw Terminals
Spring Terminals
Wiring Diagrams
Power Supply
Control Panel
Sun Shading Drives
Control Lines
Local Push Buttons
Locking Contact/Building Control System
Fault Alarm Contact
Weather Station Multisense
Sensor Wind/Photo/Radio Clock
Sensor Photo/Radio Clock
Sensor Photo (180°)
Sensor Outside Temperature
Sensor Inside Temperature
7 Overview
Start Menu
Status Display
Typical Approaches for Commissioning
8 Commissioning
Planning with Quickstart
Language
Time
Date
Channel/Channel Type
Load Data into the Actuator
Factory Reset
9 Manual Commissioning
Creating System Settings
Date and Time
Display Settings
Display Behaviour of Wisotronic
Measured Values Start Menu
Select Language
Sensor Compensation
Control Panel Temperature
Weather Station 1 (2,3) Outside Temperature
Wind Test
Service Access
Display All Menus
Manage Actuators
Manage Channels
Comfort Functions
Safety Functions
Wind Monitor
Ice Monitor
Building Control System
Sensor Allocation
Manage Products
Product Type
Copy Settings from
Delete Product
Channel Allocation
Contact Allocation, Number of Contacts
Locking Contact
Runtime up MM:ss
Runtime down MM:ss/On Period MM:ss
Slat Products
Duration of the Automatic Calibration
Manual Mode
Control Line Protocol
Managing Sensors
Software Versions
Loading Data into the Actuator
Accepting Settings
Ending Service Access
10 Measured Values, Triggers and Faults
All Measured Values
Measured Values History
Current Triggers
Trigger History
Faults
11 Factory Settings
Automatic Parameters
Product Parameters
Product Parameters for Further Products
System Parameters
12 Custom Settings
13 Troubleshooting
14 Technical Data
15 Maintenance
16 Disposal
17 Liability
18 Information for the User
19 Index
Advertisement
Quick Links
Download this manual
Wisotronic 2/3/4-channel
Installation instructions
(Keep for future use)
Valid from 1st august 2013
Sun. Light. WAREMA.
890564_c•en
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the Wisotronic 3 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for WAREMA Wisotronic 3
Weather Station WAREMA Wisotronic 2 Installation Instructions Manual
(128 pages)
Weather Station WAREMA Wisotronic 4 Installation Instructions Manual
(128 pages)
Weather Station WAREMA EWFS Weather station plus Operating And Installation Instructions
(13 pages)
Weather Station WAREMA WMS Weather Station Eco Operating And Installation Instructions
(13 pages)
Weather Station WAREMA EWFS Weather station eco Operating And Installation Instructions
(9 pages)
Weather Station WAREMA Weather station Operating And Installation Instructions
Weather station for warema climatronic. (4 pages)
Weather Station WAREMA Omnexo Weather station pro Operating And Installation Instructions
(5 pages)
Summarization of Contents
Safety instructions
Meanings of symbols and pictographs
Explains warning symbols and their meanings used in the manual.
Intended use
Details the product's designated purpose and limitations for proper operation.
Target group
Identifies the intended audience for these installation instructions.
General safety instructions
Provides overarching safety guidelines for the control system's automatic operation.
Working safely
Outlines procedures for safe installation, connection, repair, and maintenance.
Retrofitting and modifications
Advises on procedures and potential risks when altering the system.
Additional documents
Lists related documentation available for further reference.
Basic software versions
Specifies the software versions the manual is based on.
Introduction
Operating elements
Describes the components of the Wisotronic control panel interface.
Principal structure of a Wisotronic system
Illustrates the system architecture and component connections.
Concept
Explains the fundamental system logic of products, channels, groups, and scenes.
Sensor
Weather station multisense
Details the features and installation of the multisense weather station.
Sensor Wind/Photo/Radio Clock
Describes a sensor combining wind, photo, and radio clock functions.
Sensor Photo/Radio Clock
Details a sensor for light-dependent control with radio clock.
Sensor Photo (180°)
Describes a photo sensor with a 180° detection range.
Sensor Outside temperature
Explains the sensor for measuring external temperature.
Sensor Inside temperature
Details the sensor for measuring internal room temperature.
Installation
Scope of delivery
Lists all items included in the Wisotronic package.
Options
Outlines available additional features and accessories.
Procedure
Provides a step-by-step guide for system installation.
Mounting the power unit
Details the installation process for the power unit in different housing types.
Installing the control panel
Explains how to mount the Wisotronic control panel on various surfaces.
Connection
Connection information
General guidelines and warnings for connecting components.
Terminals
Describes the screw and spring terminals for wiring connections.
Wiring diagrams
Provides visual guides for connecting various system components.
Overview
Start menu
Describes the initial screen displayed upon system startup.
Typical approaches for commissioning
Outlines different methods for setting up the Wisotronic system.
Commissioning
Planning with Quickstart
Guides users through initial system setup using a guided process.
System settings
Creating system settings
Overview of how to create and manage system settings.
Manage actuators
Manage channels
Comfort functions
Configuring user-friendly features like automatic sun shading control.
Safety functions
Setting up protective functions like wind or ice monitoring.
Sensor allocation
Assigning sensors to specific channels for control.
Manage products
Product type
Selecting the type of sun shading product being controlled.
Copy settings from...
Duplicating configurations from one product to another.
Delete product
Removing a configured product from the system.
Channel allocation
Assigning a product to a specific control channel.
Contact allocation, Number of contacts
Assigning physical contacts to products.
Locking contact
Configuring contacts to lock product operation.
Runtime UP mm:ss
Setting the time for upward movement of a product.
Runtime DOWN mm:ss/On period mm:ss
Setting downward movement or on-time for products.
Slat products
Adjusting slat angles for light control in blinds.
Duration of the automatic calibration
Setting time for drive motor calibration to compensate for slip.
Manual mode
Configuring different modes for local product operation.
Control line protocol
Adapting the protocol for specific motor control units.
Managing sensors
Software versions
Loading data into the actuator
Accepting settings
Ending service access
Measured values, triggers and faults
All measured values
Displays all current sensor readings and system data.
Measured values history
Provides historical data and graphs of measured values.
Current triggers
Shows active commands or events currently affecting the system.
Trigger history
Logs past commands and events that occurred in the system.
Faults
Lists any errors or malfunctions detected in the system.
Factory settings
Automatic parameters
Default settings for automatic control functions of different products.
Product parameters
Specific settings for various WAREMA sun shading products.
Product parameters for further products
Additional product-specific settings for extended compatibility.
System parameters
Basic system-wide parameters affecting overall functionality.
Custom settings
Troubleshooting
Technical data
Maintenance
Disposal
Liability
Information for the user
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the Wisotronic 3 and is the answer not in the manual?
Questions and answers