INSTALLATION INSTRUCTIONS Universal Air Series !! NOTE !! Covers the following models: 9000 Series 6000 Series To ensure that the system is installed properly, provide your electrician with these instructions.
ELECTRICAL CONNECTIONS If your system was configured to include a 120VAC power cord, ensure that the proper receptacle has been installed (a dedicated circuit is required). DO NOT under any circumstances modify a 20 Amp plug to fit into a 15 Amp receptacle or use an extension cord.
Page 4
ELECTRICAL CONNECTIONS OPTION 2 GFCI Installed in Main Service Panel 20-60AMP If the manufacturer of your homes main breaker panel makes a GFCI HARDWIRED breaker, you may be able to add it to an open slot in the panel. MAIN BREAKER PANEL INLINE SPA DISCONNECT PORTABLE SPA LINE 1...
Page 5
ELECTRICAL CONNECTIONS OPTION 3 Systems with GFCI Included Your system may have an integrated GFCI located on the left side of the control box BUILT-IN SYSTEM GFCI as shown below. If a GFCI is present there is NO need for additional GFCI protection illustrated in options 2 &...
Page 6
GFCI WIRING DETAIL When a GFCI circuit breaker is used in the installation of your spa, it is important that it has been properly installed. Often this component has been improperly installed causing the breaker to trip the instant the system is turned on. Below is an illustration of a typical GFCI breaker installation. WARNING: Refer to Circuit Breaker Manufacturers installation instructions.
SYSTEM CONFIGURATION Congratulations on your purchase of the Universal Series Control System from Hydro-Quip. This series of controls has been developed to allow you complete flexibility during your installation. This Control System is configured to allow you to choose the voltage for each circuit at the time of installation.
Page 10
CONNECTION Below is an illustration showing our exclusive colored receptacles, located on the right side of the control box. Use this illustration when connecting spa components. Receptacle Color Chart Pump 1 / 2-Speed Pump 1 / 2-Speed PINK BROWN Pump 2 / 1 or 2-Speed Pump 2 / 2-Speed WHITE PINK...
Page 11
CONNECTION Spaside Control: If equipped, install the Spaside Control per the manufacturers instructions. Once installed, connect the Spaside Control plug into the receptacle provided on the side of the control box (as shown in the illustration below). If the Spaside Control includes a thermostat, installed the temperature probe into the dry-well of the spa.
SYSTEM STARTUP System Startup Procedures: Using the “System Operation Manual” provided with the unit, complete the following procedures: 1) Read and familiarize yourself with the system Operation manual. 2) Unplug the power cord (120-volt system only) or turn the electrical power “OFF” at the service or breaker panel (120 or 240 volt permanently connected units.) 3) Open all WATER shut-off valves.
TROUBLESHOOTING The following describes situations and possible solutions to common problems may encounter as a spa owner. Note: your system may not include all components listed. NOTHING OPERATES Main Breaker is OFF - Set to On. Sub-Panel Breaker Off - Set to On. System GFCI Off - Set to On.
Page 14
NO THERAPY JET OPERATION Water Shut-Off Valves are Closed - Open Shut-Off valves. Jets Not Properly Adjusted - Adjust Jets properly. Diverter Valve Not Properly Adjusted - Adjust diverter valve properly. Thermal Overload Tripping - Check for restricted flow of water. NO LIGHT OPERATION Light Bulb Defective - Replace bulb or contact your local dealer.
SPECIAL CONSIDERATIONS If your system is equipped with a pressure switch, the function of the pressure switch is to turn the heater off if the pump stops operating or if there is a restricted water flow (dirty filter, obstruction in the spa plumbing etc.).
Page 16
SYSTEM DATA LABEL The system data label is located on the control box. This label is very important and contains information you will need to establish your electrical service. The voltage and amperage ratings are shown on the bottom of the label. Product, Model, Serial and Code numbers are also shown on the label.
Page 17
WARRANTY INFORMATION To all original purchasers, HYDROQUIP warrants its products to be free from defects in material and workmanship for a period of one year from the date of purchase. HYDROQUIP will repair or replace the part, which in our opinion, is defective.
Page 18
NOTES Use this section to jot down any information you may need at a later date. Dealer: Date of Install: Contact: Phone: Address: City: State: Zip: Notes:...
Need help?
Do you have a question about the 6000 Series and is the answer not in the manual?