CS7500/CS6500 - BASIC OPERATION
TEMPERATURE SET KEY
ACCESSORY KEY
Pump 1 Key: Press this key once to turn Pump 1 onto Low speed, press this key a second time to turn
Pump 1 onto High speed, a third press will turn the pump off. A built-in timer will shut the pump off after 20
minutes of operation unless done so manually. The Pump 1 indicator will illuminate while the pump is
running in High speed and flash while it is in Low speed.
Pump 2/Blower Key: Press this key once to activate Pump 2 or Blower. A built-in timer will shut the
device off after 20 minutes of operation unless done so manually. The indicator will illuminate while the is
running is running.
Light/Enter Key: Press this key to turn the light on, a second press will turn the light off. If light circuit is
set to two intensity light in the Low Level Setting first press will activate low intensity, second press will
activate full intensity. The light will automatically shut off after 2 hours.
Temperature Set Key: Press the Up/Down Arrow key to increase the desired temperature, release and
press again to decrease the desired temperature. The temperature can be adjusted in 1°F increments
from 59°F to 104°F (5°C to 40°C). The new setting will remain on the display for 5 seconds as a
confirmation. During this time the Temperature Program indicator will be illuminated to let you know this
is the desired and not the actual temperature. After 5 seconds the display will return to the current
temperature reading. When the temperature drops to 1°F below the set temperature, the heater will be
turned on until the temperature is 1°F above the set temperature. The Heater "On" indicator will
illuminate while the heater is on and flash when there is a call for heat and the heater has not yet been
activated or is dis-abled due to current limiting .
85-0150-B
LIGHT KEY
PUMP 1 KEY
REV.07
INDICATOR
LIGHTS
LED
FUNCTION
02/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CS7500 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HydroQuip CS7500 Series

  • Page 1 CS7500/CS6500 - BASIC OPERATION TEMPERATURE SET KEY LIGHT KEY ACCESSORY KEY PUMP 1 KEY INDICATOR LIGHTS FUNCTION Pump 1 Key: Press this key once to turn Pump 1 onto Low speed, press this key a second time to turn Pump 1 onto High speed, a third press will turn the pump off. A built-in timer will shut the pump off after 20 minutes of operation unless done so manually.
  • Page 2 CS7500/CS6500 - POWER CONNECTION Use the illustrations and instructions below to connect your input power wiring. Always refer to the wiring diagram provided with your control (located inside the hinged cover) prior to connecting any wires. WARNING - Secure wires as defined by the NEC and in compliance with any local codes in effect at the time of installation.
  • Page 3 CS7500/CS6500 - LOW LEVEL PROGRAMMING The CS6500/7500 series control systems offer the user the unique ability to re-configure the layout of the keypad buttons to accommodate a one or two component system. Follow the instructions below paying attention to the “Accessory Configuration” to define the desired button layout. The system is supplied with (2) keypad overlays for to cover either configuration.
  • Page 4 CS7500/CS6500 - ERROR MESSAGES PRESSURE or FLOW SWITCH ACTIVATED - This error is an indication the pressure or flow switch is not opening when the pump is off, the programming is not correct, or low level programming has just been done with the pump running. Confirm proper system programming and/or pressure switch calibration Contact your local spa dealer PRESSURE or FLOW SWITCH NOT ACTIVATED - This error is an indication the pressure or...