Tools Needed - Desa D20N Owner's Manual

Desa owner's operation and installation manual portable forced air heaters d20n, d30n, d44n
Table of Contents

Advertisement

D20N, D30N AND D44N MODELS
PORTABLE FORCED AIR HEATERS
ASSEMBLY
These models are furnished with wheels and
handles. Wheels, handles, and the mounting
hardware are found in the shipping carton.

TOOLS NEEDED

• Medium Phillips Screwdriver
• 3/8" Open or Adjustable Wrench
• Hammer
1. Slide axle through wheel support
frame. Install wheels on axle.
IMPORTANT:
When installing wheels,
point extended hub of wheels toward
wheel support frame (see Figure 3).
2. Place cap nuts on axle ends. Gently tap
with hammer to secure.
3. Place heater on wheel support frame.
For D20N model, make sure outlet end
(front) of heater is over wheels. For
D30N and D44N models, make sure air
inlet end (rear) of heater is over wheels.
Line up holes on fuel tank flange with
holes on wheel support frame.
4. For D20N model, place rear handle on
top of fuel tank flange. For D30N and
D44N models, place front handle and
rear handle on top of fuel tank flange.
Insert screws through handle(s), fuel
tank flange, and wheel support frame.
Attach nut finger tight after each screw
is inserted.
5. After all screws are inserted, tighten
nuts firmly.
VENTILATION
WARNING: Follow the mini-
mum fresh, outside air ventilation
requirements. If proper fresh, out-
side air ventilation is not provided,
carbon monoxide poisoning can
occur. Provide proper fresh, out-
side air ventilation before running
heater.
D20N Model
Hot Air
Outlet
Fuel
Tank
Flange
Cap Nut
Screw
Hot Air
Outlet
Fuel
Tank
Flange
Wheel
Support
Frame
Wheel
Nut
Cap Nut
Figure 3 - Wheel and Handle Assembly
Provide a fresh air opening of at least 2800
square cm (three square feet) for each
100,000 Btu/Hr rating. Provide extra fresh
air if more heaters are being used.
Example:
A 150,000 Btu/Hr heater requires
one of the following:
• a two-car garage door [4.9 m (16 ft.) open-
ing] raised 9 cm (3.5 inches)
4
Sleeve Cap
Screw
Axle
Nut
Wheel
Front
Handle
Extended
Axle
Hub
• a single-car garage door [2.75 m (9 ft.)
opening] raised 15.25 cm (6 inches)
• two, 76 cm (30 inch) windows raised 28
cm (11 inches)
Handle
Air
Inlet
Extended
Hub
Wheel Support
Frame
Rear
Handle
Air
Inlet
D30N and D44N Models
105843

Advertisement

Table of Contents
loading

This manual is also suitable for:

D44nD30n

Table of Contents