Service Bulletin
This document explains how to troubleshoot and resolve treadmill elevation
errors. Follow the steps below to assess where a potential issue may be hap-
pening.
As a user inclines the treadmill, the MCB sends VAC to power the elevation motor. The power being
sent depends on the input voltage (i.e. 110 VAC treadmills have a 110 VAC elevation motor and 220
VAC treadmills have a 220 VAC elevation motor). The MCB also sends 5 VDC to the elevation sensor
(potentiometer), mounted on the elevation motor, for positioning feedback.
Elevation related errors
The
"Elevation
Stall" code is triggered by the display when the elevation motor has been commanded to move
but the display does not sense any movement.
The
"Elevation
Lost" code is triggered by the display when there is no elevation motor detected.
The
"Elevation
Range" code is triggered by the display when the elevation incline number is far below or above
the Elevation 0% and Elevation Max setting numbers.
Embedded "Error 38" and "Error 41" is triggered when
incline is stuck.
Tools Required
Phillips Head Screwdriver
Multimeter

Treadmill Elevation Troubleshooting

Warning: the following procedure requires the power to be on.
Please exercise caution when working around live electrical components
Applies to: 8 Series, E-Series, and S-Series Treadmills
incline is out of range
and "Error 42" is triggered when
Rev. D
Page 1
637-4301 Rev. D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S Series and is the answer not in the manual?

Questions and answers

Summarization of Contents

Treadmill Elevation Troubleshooting
Elevation Error Codes Explained
Lists specific error codes like "Elevation Stall", "Elevation Lost", "Elevation Range", and embedded errors.
Troubleshooting Tools
Lists essential tools for troubleshooting, including a Phillips head screwdriver and multimeter.
Console Elevation Range Calibration
Explains how to calibrate elevation settings and lists new/old parameter values for different models.
Potentiometer Range Troubleshooting (Error 38/41)
Details steps to diagnose and fix "Error Code 38" and "Error 41" related to potentiometer range issues.
Elevation Stall Error Troubleshooting
Provides procedures to troubleshoot and resolve "Elevation Stall" errors, including calibration and checks.