Contents Safety notes Environmental protection and recycling Guarantee Intended use Operation Description Shutdown Care and maintenance Installation instructions for qualified personnel Installation Fitting the insulation 10-12 13-14 Connection examples Commissioning Unit dimensions and technical data 16-19 Carefully read this operating manual prior to commissioning/using the units! This operating manual is a translation of the German original.
REMKO HPS 500, MPS 800, MPS 1000 Safety notes Carefully read the operating manual The electrical power supply is to be ■ before placing the unit in service for adapted to the requirements of the the first time. It provides useful tips, units.
Environmental Intended use protection and recycling The buffer tanks are employed for the Disposing of packaging storage of hot water in all types of hot water central heating systems (solid All products are packed for transport fuel/oil-fired boilers, heat pumps, solar in environmentally friendly materials.
(hydraulic compensators) or series of the installation provided by the buffers. customer. The insulation of the HPS 500 and CAUTION MPS 800/1000 hot water tanks consists When emptying the storage tank, of high-efficiency double-lining thermal hot water may escape! insulation.
Care and maintenance Care If the storage tank is not heated or if hot water is removed, no water should Clean the units with a damp cloth be dripping from the safety valve. If this ■ (by adding a liquid household does occur, either the pressure in the cleaner, for instance).
REMKO HPS 500, MPS 800, MPS 1000 NOTE When planning the unit's installation ■ surface and selecting the installation Installation should only be location, note the total weight of performed by authorised the buffer tank, including the weight specialists. The hot water must be prepared...
Page 9
Central heating connection Buffer tank with auxiliary heater (immersion heater elements) Before being put into service, the heat distribution system must be flushed in Electric booster heaters (immersion order to remove any soiling (e.g. scale) heater elements) must be equipped from the heating cycle.
REMKO HPS 500, MPS 800, MPS 1000 Fitting the insulation To install the insulation, proceed as follows: 1. Open the packaging and pull 3. Hook the supplied cover assembly the perforated insulation section strips over the hooked closure strip. onto the connections with the This will prevent the hooked closure matting pointing inwards.
Page 11
7. Fit the supplied collars to the 5. Insert the round section of insulation connections. on top of the storage tank and fix it in place by pressing down lightly. CAUTION In order to achieve optimum heat insulation, there must not be an air gap between the round section and the insulation.
Page 12
REMKO HPS 500, MPS 800, MPS 1000 The insulation must not be bent or pushed in, as this risks damage (stress whitening). Any stress whitening which occurs through improper handling can be carefully removed or minimised using a hot-air blower.
B: WFK indoor unit 2: Mixed heating cycle C: External probe 3: Hot water D: HPS 500 storage tank example 4: Cold water This hydraulic circuit diagram is only to be used as a planning aid, and does not replace an installation drawing!
Page 14
REMKO HPS 500, MPS 800, MPS 1000 MPS 800/MPS 1000 connection example Legend A: Outdoor unit 1: Hot water B: WFK indoor unit 2: Cold water C: External probe 3: Unmixed heating cycle D: MPS 800 or MPS 1000 storage tank...
Commissioning During the heating process, all expansion NOTE water generated in the storage tank Commissioning should only be must be captured by an appropriate performed and documented by expansion vessel. specially trained personnel. (DIN-VDI 2035) Flange installation port 1. Check all connections, even those which were sealed ex works Depending on the design of your (flange), for leak-tightness.
REMKO HPS 500, MPS 800, MPS 1000 Unit dimensions and technical data HPS 500 6/4" 6/4" 6/4" Øg exterior 6/4" 6/4" 6/4" 6/4" 6/4" 6/4" 40° 40° 6/4" 6/4" 1/2" Flange 12xM12.1 bolts Nominal Max. Operating Test Tilt height Weight...
Page 17
MPS 800 6/4“ F 1/2“ F 6/4“ F 6/4“ F 6/4“ F ø 790 1/2“ F 6/4“ F 6/4“ F Sensor strips 1/2“ F 6/4“ F 6/4“ F 6/4“ F 1/2“ F 6/4“ F 6/4“ F Tilt height without insulation: 1750 mm Diameter with insulation: 990 mm Height with insulation: 1735 mm Nominal...
Page 18
REMKO HPS 500, MPS 800, MPS 1000 MPS 1000 6/4“ F 1/2“ F 6/4“ F 6/4“ F 6/4“ F ø 790 1/2“ F 6/4“ F 6/4“ F Sensor strips 1/2“ F 6/4“ F 6/4“ F 6/4“ F 1/2“ F 6/4“ F 6/4“...
Page 19
Technical data for the insulation Designation Value Mass per unit area kg/m Insulation thickness Thermal conductivity λ W/mK 0.038 (calculated) For specification, see rel. product folder Standby energy consumption (in accordance with EN 60379) Thermal resistance °C Max. continuous load 110 °C (inside) Fire class B2 in accordance with DIN 4102 2 (or 3), divided outside of the connection...