Our guarantee becomes null and void if the unit is used, set up or maintained improperly, or if modifications are made to the supplied unit without our prior consent. Subject to alterations! Warm Water Wall-Mounted Heating Units REMKO PWW 6000 Contents Contents Page Page...
◊ Never let water get inside the units. The REMKO PWW unit should be connected via shut- off valve, automatic dehumidifier and screw attach- ◊ All of the unit‘s electrical lines must be protected ments in the supply and return lines.
Connection to the heating system Unit Assembly ◊ The REMKO PWW is to be connected by the cus- tomer via the shut-off valve, automatic dehumidifier Brackets and screws in the supply and return lines. Brackets for wall and ceiling assembly (2 per unit) are Use compensators if necessary.
Sample Assemblies Circulation / Fresh air mode via the roof Circulation / Fresh air mode via the outside wall Wall lead-through in Customer- accordance with the size installed of the air intake grille Customer-installed FK MLK frame The mixed-air box is at- Customer-installed tached to the outer wall by means of the wall...
6. Make sure that all air outlet openings are opened. Connecting the units 7. Ensure that the distance between the fan wheel and Standard REMKO PWW models are equipped with ax- housing is the same all the way around. ial fans that have external rotary current motors for a 8.
Service and Care Maintenance REMKO PWW units require virtually no maintenance Replacing the fan when operated normally. They should, however, be 1. Disconnect the electrical connection of the motor. checked regularly and, if necessary, cleaned, to ensure 2.
"guarantee certificate" cations and legal requirements, or if modifications are enclosed with all units and send it back to REMKO GmbH made to the units. & Co. KG...
Accessories Air intake accessories The units are outfitted at the factory FK filter box with horizontal air outlet flaps. The filter box with pocket filter is designed for direct at- The individually adjustable fins allow tachment to the unit. the flow of warm air to be aimed in two directions.
Page 11
Wiring diagram Frost protection mechanism The frost protection thermostat is a precise water temperature regulator that can also be retrofitted to the surface of the pipe connections. The supplied tension strap with clamps makes it possible to assemble it at a later time without having the drain the heating system.
SW 2 - 380 DI switching unit Rotary current 400 volt, fan 2-speed Group switching maximum electrical capacity 4 kW The switching unit is suitable for group switching. Sev- Wall-mounted, motor protected by integrated thermal eral motors wired the same way can be connected to contacts in the fan motor.
Page 13
SW 1.1 W switching unit Switching on again after a problem Rotary current 230 volt, fan 2-speed maximum electrical capacity 4 kW Each time the power supply is interrupted or the fan malfunctions, the operating mode switch has to be reset Wall-mounted, full motor protection through integrated to “0/Release”! thermal contacts, room thermostats and frost protection...
Page 14
SW 2.1 D switching unit Rotary current 400 volt, fan 2-speed Switching on again after a problem maximum electrical capacity 4 kW Each time the power supply is interrupted or the fan Wall-mounted, full motor protection through integrated malfunctions, the operating mode switch has to be reset connections for thermal contact, connection terminals to “0/Release”! for thermal contacts, room thermostats and frost protec-...
Page 15
SW 2.2 DSK switching unit Switching on again after a problem Rotary current 400 volt, fan 2-speed maximum electrical capacity 4 kW Each time the power supply is interrupted or the fan malfunctions, the operating mode switch has to be reset Wall-mounted, full motor protection through integrated to “0/Release”! connections for thermal contacts, connection terminals...
Page 16
SW 2.2 DPP switching unit Switching on again after a problem Rotary current 400 volt, fan 2-speed maximum electrical capacity 4 kW Each time the power supply is interrupted or the fan malfunctions, the operating mode switch has to be reset Wall-mounted, full motor protection through integrated to “0/Release”! connections for thermal contacts, connection terminals...
Page 17
Motor control units, 5-speed Fan motor wiring diagrams 5-speed control unit for alternating and rotary current with operating light. The motor is protected by connect- ing thermal contacts. Motor with 2 speeds, ∆ / Y switch and thermal contacts Should a problem occur (when the thermal contacts are activated), the internal main contactor lapses and inter- High-speed Low-speed...
Page 20
REMKO GmbH & Co. KG Klima- und Wärmetechnik 32791 Lage, Im Seelenkamp 12 32777 Lage, PO Box 1827 Phone +49 5232 606-0 +49 5232 606-260 E-mail info@remko.de Internet www.remko.de...