REMKO EWS 200 E Assembly And Operating Instructions Manual
REMKO EWS 200 E Assembly And Operating Instructions Manual

REMKO EWS 200 E Assembly And Operating Instructions Manual

Storage tank systems for domestic hot water

Advertisement

Quick Links

Assembly and operating instructions
REMKO storage tank systems EWS 200E / 300E / 500E
Storage tank for domestic hot water
Read the instructions prior to performing any task!
0191-2018-08 Edition 1, en_GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EWS 200 E and is the answer not in the manual?

Questions and answers

Summary of Contents for REMKO EWS 200 E

  • Page 1 Assembly and operating instructions REMKO storage tank systems EWS 200E / 300E / 500E Storage tank for domestic hot water Read the instructions prior to performing any task! 0191-2018-08 Edition 1, en_GB...
  • Page 2 Read these operating instructions carefully before commis- sioning / using this device! These instructions are an integral part of the system and must always be kept near or on the device. Subject to modifications; No liability accepted for errors or mis- prints! Installation and operating instructions (translation of the orig- inal)
  • Page 3: Table Of Contents

    Table of contents Safety and usage instructions......................4 1.1 General safety notes........................4 1.2 Identification of notes........................4 1.3 Personnel qualifications........................4 1.4 Dangers of failure to observe the safety notes................4 1.5 Safety-conscious working....................... 4 1.6 Safety instructions for the operator....................5 1.7 Safety notes for installation and inspection tasks................
  • Page 4: Safety And Usage Instructions

    REMKO storage tank systems Safety and usage instructions CAUTION! This combination of symbol and signal word 1.1 General safety notes warns of a potentially hazardous situation, which if not avoided may cause injury or mate- Carefully read the operating manual before com- rial and environmental damage.
  • Page 5: Safety Instructions For The Operator

    "certificate of warranty" to oughly read the operating manual. REMKO GmbH & Co. KG at the time when the Work on the system may only ever be carried units are purchased and commissioned.
  • Page 6: Environmental Protection And Recycling

    REMKO storage tank systems 1.12 Environmental protection and recycling Disposal of packaging All products are packed for transport in environ- mentally friendly materials. Make a valuable contri- bution to reducing waste and sustaining raw mate- rials. Only dispose of packaging at approved collection points.
  • Page 7: Technical Data

    Technical data 2.1 Unit data Series EWS 200E EWS 300E EWS 500E Drinking water volume Heat exchanger surface Heat exchanger contents 22.6 43.0 Storage tank volume Max. operating pressure Max. permissible operating temp. °C Max. drawing quantity when l/min 19.8 22.8 drawing continuously at 45 °C Standby energy...
  • Page 8 REMKO storage tank systems Throughputs EWS 200E Throughputs EWS 200E Preparation for domestic water Inlet temperature °C Hot water temperature °C Cold water temperature °C Heating cycle flow rate 1200 1800 2400 Throughput Throughputs EWS 200E Preparation for domestic water Inlet temperature °C...
  • Page 9 Throughputs EWS 300E Throughputs EWS 300E Preparation for domestic water Inlet temperature °C Hot water temperature °C Cold water temperature °C Heating cycle flow rate 1200 1800 2400 Throughput 16.8 25.3 30.1 33.2 Throughputs EWS 300E Preparation for domestic water Inlet temperature °C Hot water temperature...
  • Page 10 REMKO storage tank systems Throughputs EWS 500E Throughputs EWS 500E Preparation for domestic water Inlet temperature °C Hot water temperature °C Cold water temperature °C Heating cycle flow rate 1200 1800 2400 Throughput Throughputs EWS 500E Preparation for domestic water Inlet temperature °C...
  • Page 11: Unit Dimensions

    2.2 Unit dimensions EWS 200E Fig. 1: Unit dimensions (all measurements in mm) 1: Magnesium anode 8: Cleaning opening 2: Venting 9: Insertion dimension 3: PU insulation A: Hot water 4: Probe sleeve B: Inlet 5: Sealing plug C: Circulation 6: Thermometer D: Return flow 7: Tilt height...
  • Page 12 REMKO storage tank systems EWS 300E R1595 ***) Fig. 2: Unit dimensions (all measurements in mm) 1: Magnesium anode 7: Tilt height 2: PU insulation A: Hot water 3: Max. installation length 450 mm B: Inlet 4: Adjustable feet C: Circulation...
  • Page 13 EWS 500E Fig. 3: Unit dimensions (all measurements in mm) Storage tank cover 11: Tilt height without storage tank cover Anode (rotated in the sectional drawing) 12: Name plate, anode instructions, installation Fleece insulation (2x) instructions Thermometer 13: F1,F2 probe PU insulation 14: 1”...
  • Page 14: Unit Description

    A blank flange cover is installed to retrofit a fine- tube heat exchanger or a flange heating cartridge (legionella protection). REMKO GmbH & Co. KG herewith confirms that the supplied product corresponds to the UBA (German Environment Agency) positive list.
  • Page 15: Installation Instructions For Qualified Personnel

    Installation instructions Assembly for qualified personnel Check the contents of the packaging for com- pleteness and check the unit for visible trans- General instructions prior to installation port damage. Immediately notify your contract partner of any deficiencies. Ensure that the area in which the unit is to be The storage tank may not be transported with operated is free of frost and easily accessible the fine-tube heat exchanger installed.
  • Page 16: Corrosion Protection

    REMKO storage tank systems Corrosion protection Oxygen always plays a role if metal materials in a heating system corrode. pH values and the salt content also play a major role. The challenge: A licenced plumber who would like to be able to guarantee his cus-...
  • Page 17 NOTICE! Heat pump systems and components from REMKO must be filled and operated with deionised water (completely desalinated). We also recommend the use of the complete heating protection unit available from us. Full protection with glycol should be used in cooling systems. The system water should be tested each time the plant is serviced, but at least once a year.
  • Page 18: Installation

    NOTICE! Clean, thin, non-aggressive and non- explosive The EWS 200E storage tank may only be oper- media without any solid or long-fibred compo- ated with the following REMKO heat pumps: nents Cooling liquids that are free of mineral oil –...
  • Page 19 A type-examination tested safety group in accord- testing, return flow, drainage and safety valve with ance with DIN 1988 must be installed in the water expansion water drain and is installed between the connection of the cold water line (cold water cold water supply and cold water feed of the supply) for closed hot water heaters.
  • Page 20 REMKO storage tank systems After the water connection is made and bubble- free filling of the tank takes place, the connected fitting must be tested to ensure it is functioning. When lifting or turning (venting) the safety valve test knob, the water must be able to flow out prop- erly without being hindered by the expansion tank drain funnel.
  • Page 21: Flange Heating Cartridge Electrical Wiring

    Installation example - hydraulic circuit diagram heat pump package HTS Stuttgart The following hydraulic circuit diagrams are only to be used as a planning aid, and do not replace an installa- tion drawing! The design and planning of customer-provided hydraulic systems must be performed by a specialist installer! NOTICE! This diagram is not suitable for the units HTS 70 and HTS 100!
  • Page 22: Before Commissioning

    REMKO storage tank systems Before commissioning Commissioning Before being placed into service, the register must be flushed in order to remove any soiling (e.g. NOTICE! scale) from the heating cycle. Commissioning should only be performed by The smooth pipe heat exchanger (register) must...
  • Page 23: Care And Maintenance

    Care and maintenance In hard water areas, the limescale which forms inside the storage tank must be removed by a spe- Care cialist after one to two years of operation. Cleaning is performed through the flange opening. Only clean the units with a damp cloth. (by adding, for instance, a liquid household Drain the storage tank cleaner).
  • Page 24: Shutdown

    Ensure that units and components are disposed of in accordance with local regulations, e.g. through authorised disposal and recycling specialists or at collection points. REMKO GmbH & Co. KG or your contractual partner will be pleased to provide a list of certified firms in your area.
  • Page 25: Spare Parts List

    Spare parts list Fig. 7: Spare parts We reserve the right to modify the dimensions and design as part of the ongoing technical development process Spare parts list Designation EWS 200E EWS 300E EWS 500E EDP no. Fine-tube heat exchanger 260200 260200 Flange heating cartridge...
  • Page 26: Index

    REMKO storage tank systems Index Care ....... . . 23...
  • Page 28 SFlb Customer Service Our equipment operates precisely and reliably. However, in the event of a fault, REMKO customer service is quickly at the scene. Our comprehensive network of experienced dealers always guarantees quick and REMKO GmbH & Co. KG reliable service.