Comfort Glow CCL3018PA/NA Owner's Operation And Installation Manual page 12

Unvented (vent-free) gas log heater
Table of Contents

Advertisement

INSTALLATION
Continued
See chart below for minimum permanent flue
opening you must provide. Attach damper clamp
so the minimum permanent flue opening will be
maintained at all times.
Chimney
Height (ft.)
' to 15'
15' to 30'
Area of Various Standard
Round Flues
Diameter (in.)
5"
"
7"
8"
INSTALLING HEATER BASE
ASSEMBLY
CAUTION: Do not remove the
data plates attached to the heater
base assembly. The data plates
contain important warranty and
safety information.
WARNING: You must secure
this heater to fireplace floor. If
not, heater will move when you
adjust controls. Moving heater
may cause a gas leak.
WARNING: If installing in a
sunken fireplace, special care
is needed. You must raise the
fireplace floor to allow access
to heater control panel. This
will insure adequate air flow
and guard against sooting and
controls being damaged. Raise
fireplace floor with noncombus-
tible material. Make sure material
is secure.
1
Minimum Permanent
Flue Opening (sq. in.)
39 sq. inches
9 sq. inches
Area (sq. in.)
0 sq. inches
9 sq. inches
39 sq. inches
51 sq. inches
www.desatech.com
CAUTION: Do not pick up
heater base assembly by the
burner. This could damage
heater. Only handle base as-
sembly by grates.
IMPORTANT: Make sure the heater burners are
level. If heater is not level, heater will not work
properly. For thermostat models, avoid damage
to thermostat bulb. Avoid nicks or sharp bends
in thermostat bulb wire. Keep thermostat bulb
in mounting bracket until ready to mount base
to floor. See Optional Positioning Of Thermostat
Sensing Bulb, page 28.
Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose (not provided) (if
allowed by local codes)
• sealant resistant to propane (propane/LP) gas,
not provided
• electric drill with 3/16" drill bit
• flathead screwdriver
1. Apply pipe joint sealant lightly to male threads
of the fitting to be threaded into gas regulator.
Connect approved flexible gas hose to gas
regulator of heater (see Figure 11).
IMPORTANT: Hold gas regulator with
wrench when connecting flexible gas hose.
2. Locate masonry screws in hardware package.
3. Position heater base assembly in fireplace.
4. Place logs in their proper position on heater base,
see Installing Logs on page 16.
5. Center heater base and logs front-to-back and
side-to-side in fireplace.
6. Carefully remove logs without moving heater
base.
Flexible Gas Hose
(if allowed by local codes)
Fitting
Figure 11 - Attaching Flexible Gas Hose
to Heater Gas Regulator
Heater Gas
Regulator
113097-01E

Advertisement

Table of Contents
loading