OPERATING HEATER

FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire de-
partment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don't try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise
4. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low "B" in the safety information above. If you don't smell
gas, go to the next step.
5. Turn control knob counterclockwise
position. Press in control knob for five (5) seconds (see Fig-
ure 19).
For more information, visit www.desatech.com
For more information, visit www.desatech.com
107882-01F
6.
7. Keep control knob pressed in for 30 seconds after lighting
8. Turn control knob counterclockwise
using the equipment shutoff valve.
Figure 19 - Control Knob In The OFF Position (Piezo Ignitor
to the OFF position.
Shown)
to the PILOT
Figure 20 - Pilot (actual pilot may vary)
OPERATING HEATER
For Your Safety Read Before Lighting
Lighting Instructions
Note: You may be running this heater for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
• If control knob does not pop up when released, contact a
qualified service person or gas supplier for repairs.
With control knob pressed in, push down and release igni-
tor button (see Figure 19). This will light pilot. The pilot is
attached to the front of burner. The pilot can be seen through
the glass panel. If needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, refer to Troubleshooting,
pages 17 through 19. Also contact a qualified service per-
son or gas supplier for repairs. Until repairs are made, light
pilot with match. To light pilot with match, see Manual
Lighting Procedure, page 14.
pilot. After 30 seconds, release control knob.
• If control knob does not pop up when released, contact a
qualified service person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 3 through 7. This
heater has a safety interlock system. Wait one (1) minute
before lighting pilot again.
heating level. The main burner should light. Set control
knob to any heat level between HI and LO.
CAUTION: Do not try to adjust heating levels by
Ignitor Button
IGNITOR
Thermocouple
to desired
Control Knob
Ignitor Electrode
Pilot Burner
13
13