Preventative Maintenance Schedule - Master B350CE Owner's Manual

High pressure portable forced air heater
Table of Contents

Advertisement

PREVENTATIVE
MAINTENANCE
SCHEDULE
10
Never service heater while it is plugged in, operating, or hot.
Severe burns and electrical shock can occur.
Item
How Often
Fuel tank
Flush every 150-200 hours
of operation or as needed.
Filler neck screen
Check for trash when
filling fuel tank. Clean
when dirty.
Fuel filter assembly
Clean twice a heating
(Fuel tank)
season or replace as
needed.
Fuel filter lines
Check and tighten loose
connections occasionally.
Fuel filter (Pump)
Clean fuel filter element
every 250 hours.
Spark plug
Clean and regap every 300
hours of operation or
replace as needed.
Fan blades
Clean each season or as
needed.
Air passages around
Check each season for dirt
burner head
and trash.
Motor
Not required, permanently
lubricated.
WARNING
How To
See Storage, page 9.
Lift out of fuel tank and rinse
with clean kerosene.
See Fuel Filters, page 17.
See Fuel Lines, Page 16.
See Fuel Filters, page 17.
See Spark Plug, page 15.
See Fan Blades, page 14.
Remove dirt and trash with
clean, soft cloth.
101964

Advertisement

Table of Contents
loading

Table of Contents

Save PDF