Manuals
Brands
Roche Manuals
Measuring Instruments
Cedex Bio HT
Host interface manual
Roche Cedex Bio HT Host Interface Manual
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
page
of
202
Go
/
202
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Publication Information
Intended Use for COBAS INTEGRA 400 Plus Analyzer
Intended Use for Cedex Bio HT Analyzer
Symbols and Abbreviations
What Is New in Publication Version 1.24
What Is New in Publication Version 1.23
About Communication 1
Communication Concept
Message Structure
Block Header
Block Data
Block Check
Communication Control
Parity Check
Flow Control (Hardware/Software Handshake)
Sequence Counter and Block Check Sum
Check of Block and Line Composition
Receive Timeout
Error Handling
Host Communication Handling
Synchronization and Sequence Counter Use
About Host Interface Features 2
About Host Interface Modes and Features
Patient Mode
Patient Entry
Patient Deletion
Patient Modification
Orders
Order Entry
Order Deletion
Order Modification (Add Tests)
Host Query Mode
Result Requests
About Result Requests
Example of Result Query
Example of Unspecific Result Request
Example of Result Request with Ratio (Collated Result Request)
Protocol Version
ASCII Code
Control Characters
Instrument Codes
Block Codes 4
About Block Codes
Idle and Synchronization Blocks
Block 00: Idle Block / Sync Block
Result Blocks
Block 02: Calibration Result
Block 03: Control Result
Block 04: Patient Results
Block 05: Calibration Result with Lot Information
Block 06: Control Result with Lot Information
Block 07: Patient Results with Lot Information
Block 08: Result Request Response
Block 09: Result Request
Order Blocks
Block 10: Order Entry
Block 11: Order Deletion
Block 19: Order Manipulation Response
Response to an Order Entry or Test Addition
Response to an Order or Test Deletion
Patient Blocks
Block 40: Patient Entry
Block 41: Patient Deletion
Block 42: Patient Modification
Block 49: Patient Manipulation Response
Multi-Configuration Service Blocks
Block 60: Multi-Configuration Service (MCS) Request (Host Query)
Block 61: Slot Configuration
Block 62: Sample Tube Information
Block 69: Service Request Response
Protocol Version Blocks
Block 92: Protocol Version Request
Block 93: Protocol Version Data
Control Messages Blocks
Block 99: Control Message
Line Codes 5
About Line Codes
List of Line Codes
Line Code 00: Result Data
Line Code 01: Result Time
Line Code 02: Control ID
Line Code 03: Standard Rates
Line Code 04: Calibration Curve
Line Code 07: ABS Sample Check
Line Code 10: Result Type Selection
Line Code 11: Reagent Lot Information
Line Code 12: Control Lot Information
Line Code 13: Calibration Lot Information
Line Code 15: Access Date Time
Line Code 16: Result Indexes
Line Code 40: Service Selection
Line Code 41: Slot State
Line Code 42: Tube Information
Line Code 43: Test State
Line Code 44: Cal/Cs State
Line Code 50: Patient ID
Line Code 51: Patient Information
Line Code 52: Special Order Selection
Line Code 53: Order ID
Line Code 54: Order Information
Line Code 55: Test ID
Line Code 56: Sample Name
Line Code 57: Priority Modification
Line Code 96: Error Code
Flags and Error Codes 6
About Flags
Flag X
Flag CALC (Result Error)
Flag QC
About Error Codes
List of Line Code 96 Error Codes
List of Line Code 99 Error Codes
Block Codes for Extended Host Interface 7
About Block Codes for Extended HIF
Result Blocks
Block 02: Calibration Result
Block 03: Control Result
Produced
Block 04: Sample Results
Produced
Block 05: Calibration Result with Lot Information
Produced
Block 06: Control Result with Lot Information
Produced
Block 07: Sample Results with Lot Information
Conditions Are Met
Line Code Description Iteration (1)(2)
Produced
Result Data
Operation Settings Blocks
Block 20: Operation Setting
Block 21: Operation Setting Response
Block
Service Action Blocks
Block 25: Service Action Execution
Block 26: Service Action Response
Block 27: Service Action Result Request
Block 28: Service Action Result Response
Block 29: Failed Service Action Result Response
Test Status Blocks
Block 45: Test Status Request
Block 46: Test Status Response
Block 47: Failed Test Status Request
Calibration Status Blocks
Block 52: Calibration Status Request
Block 54: Calibration Status Response
Block 57: Failed Calibration Status Request
Cassette Status Blocks
Block 50: Cassette Status Request
Block 55: Cassette Status Response
Block 59: Failed Cassette Status Request
Multi-Configuration Service Block
Block 64: Service Action Status
Message Log Blocks
Block 75: Message Log Request
Block 76: Message Log Response
Block 77: Failed Message Log Request
Sample Order Status Blocks
Block 80: Order Status Request
Block 81: Order Status Response
Block 85: Failed Order Status Request
System Status Blocks
Block 90: System Status Request
Block 91: System Status Response
Date and Time Blocks
Block 94: Date and Time Request
Block 95: Date and Time Data
Serial Number Blocks
Block 96: Serial Number Request
Block 97: Serial Number Response
Line Codes for Extended Host Interface 8
About Line Codes
List of Line Codes for Extended HIF
Line Code 06: Absorbance Raw Data
Line Code 08: FP Raw Data
Line Code 09: ISE Raw Data
Line Code 14: Validation Status
Line Code 17: Test Execution
Line Code 18: Cassette Information
Line Code 19: Calibration Information
Line Code 20: Order ID
Line Code 21: Control Information
Line Code 22: Order ID
Line Code 23: Sample Order Status
Line Code 24: Message Date Time
Line Code 25: Test Order Status
Line Code 26: Dilution Factor
Line Code 27: Rerun Result
Line Code 28: Test Status
Line Code 29: Cassette Status
Line Code 30: Operation Selection
Line Code 31: Calibrator Status
Line Code 32: Service Action Selection
Line Code 33: Control Status
Line Code 36: Cassette Definition
Line Code 37: Tests Left
Line Code 38: Diluent Status
Line Code 39: Cassette Status
Line Code 40: Service Selection
Line Code 45: Service Action Definition
Line Code 46: Currently Time or Tests Elapsed
Line Code 47: Service Due
Line Code 48: Elapsed Percentage
Line Code 49: Rack Position
Line Code 55: Test ID
Line Code 58: Service Action Result
Line Code 60: Calibration Due
Line Code 61: Test Status and Blocked Status
Line Code 62: Calibrator ID
Line Code 82: Message Icon
Line Code 83: Message String
Line Code 93: System Date Time
Line Code 94: Serial Number
Line Code 97: System Status
Troubleshooting 9
About Troubleshooting
Enabling Host Interface Tracing
Viewing the Trace File
Known Host Interface Issues
Sample Types
Collated Results
Instrument Setup 10
Setting up the Instrument for Host Communication
Setting up the Instrument for Host
Communication
Preparing an Interface Cable
About the RS-232 Cable
About the Cable Types
About the Connector Types
Connecting the Interface Cable
Configuring Host Communication
Configuring Barcode Setup
About the RS-232 Serial Interface
Signal Levels
Signal Description
About the Handshake
Hardware-Handshake
Software-Handshake
Advertisement
Quick Links
1
Intended Use for Cobas Integra 400 Plus Analyzer
Download this manual
COBAS INTEGRA 400 plus analyzer
Cedex Bio HT Analyzer
Host Interface Manual
Version 1.24
Software version 3.6/5.1
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Chapters
Table of Contents
7
About Communication 1
15
About Host Interface Features 2
27
Block Codes 4
59
Line Codes 5
81
Flags and Error Codes 6
103
Block Codes for Extended Host Interface 7
117
Line Codes for Extended Host Interface 8
139
Troubleshooting 9
173
Instrument Setup 10
183
Table of Contents
Need help?
Do you have a question about the Cedex Bio HT and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Roche Cedex Bio HT
Measuring Instruments Roche CoaguChek XS System User Manual
(66 pages)
Measuring Instruments Roche CoaguChek XS Procedures Manual
(59 pages)
Measuring Instruments Roche CoaguChek XS Plus User Manual
(112 pages)
Measuring Instruments Roche Cobas C111 Manual
(93 pages)
Measuring Instruments Roche Cedex HiRes Operator's Manual
(166 pages)
Measuring Instruments Roche CoaguChek XS Pro Operator's Manual
(140 pages)
Measuring Instruments Roche Cedex Bio Operator's Manual
(558 pages)
Measuring Instruments Roche Cedex Bio System Operator's Manual
(496 pages)
Measuring Instruments Roche Cobas C 311 Manual
Host interface (63 pages)
Measuring Instruments Roche cobas c Operator's Manual
Pack opener (22 pages)
Measuring Instruments Roche cobas c 513 Manual
(46 pages)
Measuring Instruments Roche cobas e 411 Manual
(34 pages)
Measuring Instruments Roche cobas e 411 Interface Manual
(61 pages)
Measuring Instruments Roche COBAS INTEGRA 400 plus Host Interface Manual
(202 pages)
Measuring Instruments Roche cobas h 232 Operator's Manual
(140 pages)
Measuring Instruments Roche 9180 Instructions For Use Manual
Electrolyte analyzer (186 pages)
Table of Contents
Save PDF
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the Cedex Bio HT and is the answer not in the manual?
Questions and answers