Grundfos UP 53-46 Installation And Operating Instructions Manual

Grundfos UP 53-46 Installation And Operating Instructions Manual

In-line, wet-rotor, single-speed, circulator pumps

Advertisement

GRUNDFOS INSTRUCTIONS
UP Series 200
Installation and operating instructions
In-line, wet-rotor, single-speed, circulator pumps
UP 43-70, UP 43-110, UP 53-45, UP 53-46

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UP 53-46 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
Safety Warning
General safety advice for pump installation and operation.
Electrical Work
Guidelines for electrical connections performed by qualified personnel.
Pre-installation Checklist
Confirm Correct Pump
Verify pump model, nameplate data, and performance against application needs.
Check Pump Condition
Inspect the pump for any damage that may have occurred during shipping.
Verify Electrical Requirements
Confirm voltage, phase, and frequency match pump specifications.
Pumped Liquid Requirements
Details suitable liquids and temperature limits for pump operation.
Installation Procedures
Electrical Preparation
Guide to positioning the terminal box and preparing electrical connections.
Piping Considerations
Advice on system flushing, pump location, and mounting orientation.
Connect the Pump
Instructions for physically installing the pump into the piping system.
Electrical Connection
Steps for making safe and correct electrical connections to the pump.
Starting the Pump
Vent Piping System
Procedure for removing air from the system before starting the pump.
Voltage Selection
Instructions on how to select the correct voltage for the pump.
Troubleshooting
Fault Finding Chart
A table listing common faults, their causes, and remedies.
Preliminary Checks
Steps for checking supply voltage and ensuring proper power input.
Current Measurement
Procedure for measuring pump current draw and evaluating results.
Insulation Resistance (Lead-to-Ground)
Method for testing motor winding insulation to ground.
Winding Resistance (Line-to-Line)
Procedure for measuring motor winding resistance between terminals.
Winding Resistance Chart
A reference table for acceptable winding resistance values by pump type.
Replacing Components
Removing Pump Head
Step-by-step instructions for safely removing the pump head.
Fitting Pump Head
Guide for correctly installing a new pump head and impeller assembly.
Replacing Terminal Box or Capacitor
Instructions for replacing electrical components like the terminal box or capacitor.