Carrier 48TJF Series Installation, Start-Up And Service Instructions Manual
Carrier 48TJF Series Installation, Start-Up And Service Instructions Manual

Carrier 48TJF Series Installation, Start-Up And Service Instructions Manual

Single-package rooftop heating/cooling units

Advertisement

Installation, Start-Up, and
CONTENTS
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-26
Step 1 - Provide Unit Support . . . . . . . . . . . . . . . 1
• ROOF CURB
Step 2 - Field Fabricate Ductwork . . . . . . . . . . . . 2
Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Step 4 - Rig and Place Unit . . . . . . . . . . . . . . . . . . 2
• POSITIONING
Step 5 - Install Flue Hood . . . . . . . . . . . . . . . . . . . 4
Step 6 - Install Gas Piping . . . . . . . . . . . . . . . . . . . 4
• HEAT ANTICIPATOR SETTINGS
• MANUAL OUTDOOR-AIR DAMPER
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27,28
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-33
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . 34-40
START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . . CL-1
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment
can be hazardous due to system pressure and electrical com-
ponents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance func-
tions of cleaning coils and filters and replacing filters. All
other operations should be performed by trained service per-
sonnel. When working on air-conditioning equipment, ob-
serve precautions in the literature, tags and labels attached
to the unit, and other safety precautions that apply.
Follow all safety codes. Wear safety glasses and work gloves.
Use quenching cloth for unbrazing operations. Have fire ex-
tinguishers available for all brazing operations.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
PC 111
Tab
1a 6a
Single-Package Rooftop Heating/Cooling Units
Service Instructions
Page
Catalog No. 534-852
Printed in U.S.A.
48TJD/TJE/TJF005-007
Disconnect gas piping from unit when leak
testing at pressure greater than
Pressures greater than
gas valve damage resulting in hazardous
condition. If gas valve is subjected to pres-
sure greater than
placed before use. When pressure testing
field-supplied gas piping at pressures of
1
psig or less, a unit connected to such
2
piping must be isolated by manually clos-
ing the gas valve.
Before performing service or maintenance operations on
unit, turn off main power switch to unit. Electrical shock
could cause personal injury.
INSTALLATION
Unit is shipped in the vertical discharge configuration. To
convert to horizontal configuration, remove screws from side
duct opening covers and remove covers. Using the same screws,
install covers on vertical duct openings with the insulation-
side down. Seals around duct openings must be tight. See
Fig. 1.
Step 1 - Provide Unit Support
ROOF CURB - Assemble and install accessory roof curb
in accordance with instructions shipped with curb. See
Fig. 2. Install insulation, cant strips, roofing felt, and counter
flashing as shown. Ductwork must be attached to curb, not
to the unit. The accessory thru-the-bottom power connection
package must be installed before the unit is set on the roof
curb. If field installed (through the roof curb) gas connec-
tions are desired, use factory supplied
and gas plate assembly to mount the through the roof curb
connection to the roof curb. Gas connections and power con-
nections to the unit must be field installed after the unit is
installed on the roof curb.
IMPORTANT: The gasketing of the unit to the roof
curb is critical for a watertight seal. Install gasket sup-
plied with the roof curb as shown in Fig. 2. Improp-
erly applied gasket can result in air leaks and poor unit
performance.
Form 48TJ-9SI
Pg 1
48TJE/TJF004
1
psig.
2
1
psig will cause
2
1
psig, it must be re-
2
3
in. pipe coupling
4
8-95
Replaces: 48TJ-3SI

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 48TJF Series and is the answer not in the manual?

Questions and answers

Summarization of Contents

Installation
Unit Support and Mounting
Instructions for supporting the unit, including roof curb and slab mount.
Field Fabricated Ductwork
Guidelines for creating and attaching ductwork to the unit and structure.
Condensate Drain Trap Installation
Procedures for installing an external trap for the condensate drain line.
Unit Rigging and Placement
Guidance on safely rigging and positioning the unit on its final location.
Flue Hood Installation
Instructions for installing the flue hood and screen assembly.
Gas Piping Installation
Details on connecting the gas supply piping to the unit, including code compliance.
Electrical Connections
Steps for making proper electrical connections, including power supply and controls.
Outdoor-Air Hood and Damper Adjustments
Procedures for adjusting outdoor-air dampers and installing the associated hood.
Evaporator-Fan Speed Adjustment
Instructions for setting the evaporator fan speed to meet jobsite conditions.
Start-Up
Unit Preparation and Pre-Start Checks
Essential steps before starting the unit, including wiring and ports.
Cooling and Heating Start-Up
Steps for initiating unit operation in cooling and heating modes.
Economizer and Fan Operation Modes
Details on economizer and fan operation for cooling and heating.
Service
Evaporator Coil Cleaning
Step-by-step instructions for cleaning the evaporator coil.
Condenser Coil Cleaning
Methods for cleaning the condenser coil, including 1-row and 2-row types.
Lubrication and Condenser-Fan Adjustment
Information on lubrication, condenser-fan adjustment, and refrigerant charge.
Refrigerant Charge Procedures
Procedures for checking and adjusting refrigerant charge using charts.
Flue Gas Passageways Inspection
Inspection and cleaning of flue collector box and heat exchanger areas.
Troubleshooting
LED Error Code Analysis
Interpretation of LED error codes for the Integrated Gas Unit Controller.
Heating Service Analysis
Troubleshooting guide for heating problems like ignition and flame issues.
Cooling Service Analysis
Troubleshooting guide for cooling issues like compressor and fan problems.
Economizer Troubleshooting
Steps to diagnose and resolve issues with both Varislide and Parablade economizers.

Table of Contents

Save PDF