Olympus TJF-Q180V Instructions Manual

Olympus TJF-Q180V Instructions Manual

Duodenovideoscope. single use soft brush (maj-1888)
Table of Contents

Advertisement

Accessories:
• Water resistant cap (MH-553)
• Biopsy valve (MB-358)
• Air/water valve (MH-438)
• Suction cleaning adapter (MH-856)
• Channel cleaning brush (BW-20T)
• Single use channel cleaning brush (BW-201T)
• AW channel cleaning adapter (MH-948)
• Single use soft brush (MAJ-1888)
MH-553
MAJ-1119
BW-20T
MH-944
BW-201T
Refer to the endoscope's companion manual, the "OPERATION MANUAL" with your endoscope model
listed on the cover, for operation information.
USA: CAUTION: Federal law restricts this device to sale by or on the order of a physician.
INSTRUCTIONS
EVIS EXERA II DUODENOVIDEOSCOPE
OLYMPUS TJF
MB-358
MH-946
Single use soft brush (MAJ-1888)
Q180V
TYPE
• Chain for water-resistant cap (MAJ-1119)
• Suction valve (MH-443)
• Mouthpiece (MB-142)
• Channel plug (MH-944)
• Injection tube (MH-946)
• Single use channel-opening cleaning brush (MAJ-1339)
• Single use combination cleaning brush (BW-412T)
MH-443
MH-438
MH-948
MAJ-1339
MB-142
MH-856
BW-412T
MAJ-1888

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TJF-Q180V and is the answer not in the manual?

Questions and answers

Summarization of Contents

Chapter 1 General Policy
1.1 Instructions
Provides guidance on using the manual and contacting Olympus for questions.
1.2 Importance of cleaning, disinfection, and sterilization
Explains the critical role of proper cleaning, disinfection, and sterilization.
1.3 Signal words
Defines signal words like WARNING, CAUTION, and NOTE used in the manual.
1.4 Precautions
Details essential safety precautions for reprocessing endoscopes and accessories.
1.5 Reprocessing before the first use
Instructions for reprocessing new, repaired, or loaned endoscopes before initial use.
1.6 Reprocessing and storage after use
Guidelines for reprocessing and storing endoscopes and accessories after patient use.
1.7 Reprocessing before patient procedure
Procedures for reprocessing endoscopes and accessories before each patient procedure.
Chapter 2 Function and Inspection of the Accessories for Reprocessing
2.1 Water resistant cap (MH-553)
Describes the function and inspection of the water resistant cap.
2.2 Channel plug (MH-944)
Details the function and inspection of the channel plug.
2.3 Injection tube (MH-946)
Explains the function and inspection of the injection tube.
2.4 Channel cleaning brush (BW-20T)
Describes the function and inspection of the channel cleaning brush.
2.5 Suction cleaning adapter (MH-856)
Explains the function and inspection of the suction cleaning adapter.
2.6 AW channel cleaning adapter (MH-948)
Details the function and inspection of the AW channel cleaning adapter.
2.7 Single use channel cleaning brush (BW-201T)
Describes the function and inspection of the single use channel cleaning brush.
2.8 Single use channel-opening cleaning brush (MAJ-1339)
Explains the function and inspection of the single use channel-opening cleaning brush.
2.9 Single use combination cleaning brush (BW-412T)
Details the function and inspection of the single use combination cleaning brush.
2.10 Single use soft brush (MAJ-1888)
Describes the function and inspection of the single use soft brush.
2.11 Chain for water-resistant cap (MAJ-1119)
Explains the function and inspection of the chain for water-resistant cap.
Chapter 3 Compatible Reprocessing Methods and Chemical Agents
3.1 Compatibility summary
Summarizes compatible reprocessing methods and chemical agents for endoscopes and accessories.
3.2 Water (for reprocessing)
Details the type of water used for leakage testing and cleaning.
3.3 Detergent solution
Specifies requirements for detergent solutions used in reprocessing.
3.4 Disinfectant solution
Guidelines for selecting and using high-level disinfectant solutions.
3.5 Rinse water
Specifies the type of water to be used for rinsing after disinfection.
3.6 Alcohol
Recommends the type of alcohol for flushing.
3.7 Ethylene oxide gas sterilization
Provides parameters for ethylene oxide gas sterilization cycles.
3.8 Steam sterilization (autoclaving)
Outlines parameters for steam sterilization (autoclaving) of accessories.
Chapter 4 Reprocessing Workflow for the Endoscope and Accessories
4.1 Workflow for manually cleaning and disinfecting the endoscope and accessories
Details the manual workflow for cleaning and disinfecting endoscopes and accessories.
4.2 Workflow for cleaning and disinfecting the endoscope and accessories using an AER
Describes the workflow for using an Automated Endoscope Reprocessor (AER).
4.3 Workflow for manually cleaning and sterilizing the endoscope and accessories
Outlines the manual workflow for cleaning and sterilizing endoscopes and accessories.
Chapter 5 Reprocessing the Endoscope (and related reprocessing accessories)
5.1 Preparing the equipment for reprocessing
Lists the necessary equipment for reprocessing the endoscope and accessories.
5.2 Precleaning the endoscope and accessories
Provides steps for precleaning endoscopes and accessories immediately after patient use.
5.3 Leakage testing of the endoscope
Details the procedure for performing a leakage test on the endoscope.
5.4 Manually cleaning the endoscope and accessories
Describes the manual cleaning process for the endoscope and its accessories.
5.5 Manually disinfecting the endoscope and accessories
Outlines the manual disinfection process for the endoscope and its accessories.
5.6 Rinsing the endoscope and accessories following disinfection
Provides instructions for rinsing the endoscope and accessories after disinfection.
5.7 Sterilizing the endoscope and accessories
Describes methods for sterilizing the endoscope and accessories.
Chapter 6 Reprocessing the Accessories
6.1 Manually cleaning the accessories
Details the manual cleaning procedures for individual accessories.
6.2 Manually disinfecting the accessories
Outlines manual disinfection procedures for individual accessories.
6.3 Rinsing the accessories following disinfection
Provides instructions for rinsing accessories after disinfection.
6.4 Sterilizing the accessories
Describes methods for sterilizing individual accessories.
Chapter 8 Storage and Disposal
8.1 Storing the disinfected endoscope and accessories
Provides guidelines for storing disinfected endoscopes and accessories.
8.2 Storing the sterilized endoscope and accessories
Details procedures for storing sterilized endoscopes and accessories.
8.3 Disposal
Instructions on the proper disposal of endoscopes, accessories, and supplies.

Table of Contents