Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Buderus Manuals
Boiler
24S
Servicing manual
Buderus 24S Servicing Manual
Gas wall hung boiler condensing
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
page
of
68
Go
/
68
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Messages - Universal Automatic Burner (UBA)
Table of Contents
1 Messages - Universal Automatic Burner
(Uba)
UBA Status Display
UBA Operating Level 1.5
Service Tool
Operating Messages
Fault Messages
2 Faults that the UBA Does Not Display
C Safety Sensor Exceeds 100 °C
Excessive Temperature Increase at Safety Sensor
Bad Plug-In Connection at Cable Loom, or Damaged Wiring
Feed Sensor above 100 °C
F2 Fuse Malfunction, or Exhaust-Gas Sensor Tripped
F Safety Sensor Exceeds 100 °C
Dripping Tap
L Short Circuit in Safety Sensor
P Safety Sensor, Loose Contact or Defective
Short Circuit in Feed Sensor
Feed Sensor, Loose Contact or Defective
C 600 Series Has Switched off after Disconnection of Diagnosis Plug
F1 Fuse Defective, or no Ionisation Message after Ignition
Ionisation Message, but no Flame
H Flame dies out after Gas Valve Is Opened
Flame Goes out During Warm-Up Phase
Mains Voltage
A Voltage in UBA too Low or too High
Mains Voltage Interrupted Following a Fault Warning Message
F3 Fuse Defect, or UBA System Error
Voltage Peaks in UBA
UBA Timer Error
External Switching Contact, E.g. Temperature Monitor for Floor Heating, Has Been Tripped
System Error
C Incorrect Cable Connection at KIM, or KIM Defective
System Error (UBA Defective)
Wiring to Gas-Burner Assembly Incorrect, or Loose Wiring Connections in UBA
UKIM Defective
P Non-Compatible UBA Fitted
Troubleshooting Tasks
Unblocking the 600 Series 11S / 19S / 24S / 24C
Chimney-Sweep Mode
Removing and Refitting the Outer Casing
Removing and Refitting the Combustion-Chamber Cover
Checking the Exhaust-Gas Sensor
Replacing the Exhaust-Gas Sensor
Checking the Air Intake and Outlet Openings
Replacing the UBA
Checking the Fan
Replacing the Fan
Checking the Wiring Connections of the UBA
Checking the Miniature Fuses
Checking the Connections for the Second Solenoid Valve, Modulating Pump and Floor Thermostat Switching Contact
Checking the Circulation Pump
Replacing the Circulation Pump
Checking the Safety Sensor
Replacing the Safety Sensor
Checking the Safety Sensor Connection Lead
Checking the Feed Sensor
Replacing the Feed Sensor
Checking the Feed Sensor Connection Lead
Checking the Domestic Hot Water
Mains Water Supply
Changing the Domestic Hot Water
Mains Water Supply
Checking the Hot Surface Ingitor
Replacing the Hot Surface Ingitor
Checking the Gas-Burner Control System for Correct Activation
Replacing the Gas Burner Fitting
Checking and Adjusting the Gas-To-Air Ratio
Measuring the Ionisation Current
Replacing the Ionisation Electrode
Checking the Three-Way Motorised Valve for Correct Operation
Replacing the Motorised Valve Body Control Valve
Replacing the Three-Way Valve
Checking the ERC/RC Connections to the UBA
Replacing the Terminal Strip
Checking Connections at the ERC or RC
Replacing the Room-Temperature Control Device
Advertisement
Quick Links
Download this manual
7210 1300 - 02/2006 GB(EN)
Servicing manual
Gas wall hung boiler condensing
600 Series - 11S / 19S / 24S / 24C
Please read thoroughly before attempting to diagnose fault
For trade use
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Troubleshooting
Troubleshooting
9
Troubleshooting tasks
47
Need help?
Do you have a question about the 24S and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Buderus 24S
Boiler Buderus 24C Servicing Manual
Gas wall hung boiler condensing (68 pages)
Boiler Buderus 600-19R Installation And Servicing Instructions
Wall-mounted condensing gas boiler (60 pages)
Boiler Buderus 500-24S Installation And Maintenance Instructions Manual
Gas wall hung boiler condensing (56 pages)
Boiler Buderus 500-24S User Manual
Gas wall hung boiler condensing (12 pages)
Boiler Buderus 500-24S Assembly Instructions Manual
(8 pages)
Boiler Buderus 600 - 11S User Manual
Gas wall hung condensing boiler (12 pages)
Boiler Buderus 600 - 11S Installation And Servicing Instructions
(72 pages)
Boiler Buderus Logano G515 Installation And Service Instructions Manual
Low-temperature oil/gas boiler buderus logano g515 (68 pages)
Boiler Buderus Logano GC124 II User Manual
Gas boiler (12 pages)
Boiler Buderus Logano G215 US User Manual
Oil and gas fired boiler (12 pages)
Boiler Buderus G124X Brochure & Specs
Atmospheric gas boilers (8 pages)
Boiler Buderus Logano GA244 Installation, Operation And Maintenance Manual
Sealed combustion hot water gas boiler (72 pages)
Boiler Buderus G124X User Manual
Atmospheric gas boilers (9 pages)
Boiler Buderus Condensing gas boiler Instructions Manual
Condensing gas boiler (12 pages)
Boiler Buderus Logamax plus GB142-24 Servicing Instructions
Condensing gas boiler (132 pages)
Boiler Buderus Logano G215 US Installation And Maintenance Instructions Manual
Oil and gas-fired boilers (72 pages)
Summarization of Contents
Preface
Important general instructions for use
Essential guidance for safe and correct operation of the boiler.
Subject to technical modifications
Document may contain minor differences due to ongoing product development.
benchmark Log Book
Information about the installation, commissioning, and service record log book.
Messages – Universal Automatic Burner (UBA)
1.1 UBA status display
Explains how operational status and error messages are shown on the UBA display.
1.2 UBA operating level 1.5
Details the UBA operating level 1.5 and its key components.
1.3 Service tool
Describes the purpose and connection of the service tool for fault diagnosis.
1.4 Operating messages
Lists and explains the various operating messages displayed by the UBA.
1.5 Fault messages
Lists and explains fault messages, including troubleshooting flow diagram references.
Faults that the UBA does not display
Hot-water mode
Addresses issues where the UBA is ready but no hot water is produced.
Heating mode
Addresses issues where the boiler fails to go into heating mode despite readiness.
Troubleshooting
Troubleshooting tasks
General advice and procedures for systematic fault diagnosis.
Unblocking the 600 Series 11S/19S/24S / 24C
Procedure to reset and unblock the UBA after a fault.
Chimney-sweep mode
Instructions for operating the boiler in chimney-sweep mode for specific tasks.
Removing and refitting the outer casing
Step-by-step guide to remove and reinstall the boiler's outer casing.
Removing and refitting the combustion-chamber cover
Steps for removing and reinstalling the combustion-chamber cover.
Checking the exhaust-gas sensor
Method for checking the functionality of the exhaust-gas sensor.
Replacing the exhaust-gas sensor
Procedure for replacing a defective exhaust-gas sensor.
Checking the air intake and outlet openings
Ensures air intake and outlet openings are clear and unobstructed.
Replacing the UBA
Detailed steps for replacing the Universal Automatic Burner (UBA).
Checking the fan
How to check if the fan is operating correctly and receiving power.
Replacing the fan
Step-by-step guide for replacing the fan unit.
Checking the wiring connections of the UBA
Verifying the tightness and correctness of UBA cable connections.
Checking the miniature fuses
Procedure for checking and replacing miniature fuses on the UBA.
Checking the connections for the second solenoid valve, modulating pump and floor thermostat switching contact
Verifying connections for critical components like solenoid valves and pumps.
Checking the circulation pump
How to check if the circulation pump is running and operational.
Replacing the circulation pump
Procedure for replacing a faulty circulation pump.
Checking the safety sensor
Method to check the resistance and temperature reading of the safety sensor.
Replacing the safety sensor
Step-by-step guide for replacing the safety sensor.
Checking the safety sensor connection lead
Verifying the integrity of the wiring to the safety sensor.
Checking the feed sensor
Method to check the resistance and temperature reading of the feed sensor.
Replacing the feed sensor
Procedure for replacing a faulty feed sensor.
Checking the feed sensor connection lead
Verifying the integrity of the wiring to the feed sensor.
Checking the domestic hot water / mains water supply
Measuring resistance of the hot water/mains water sensor against temperature.
Changing the domestic hot water / mains water supply
Procedure for replacing the hot water/mains water sensor.
Checking the hot surface ingitor
Method to check the hot surface ignitor for free throughput.
Replacing the hot surface ingitor
Step-by-step guide for replacing the hot surface ignitor.
Checking the gas-burner control system for correct activation
Verifying the correct voltage output of the gas burner control system.
Replacing the gas burner fitting
Procedure for replacing the gas burner fitting.
Checking and adjusting the gas-to-air ratio
How to check and adjust the gas-to-air ratio for optimal combustion.
Measuring the ionisation current
Procedure to measure the ionisation current for flame detection.
Replacing the ionisation electrode
Step-by-step guide for replacing the ionisation electrode.
Checking the three-way motorised valve for correct operation
Verifying the correct operation of the three-way motorised valve.
Replacing the motorised valve body control valve
Procedure for replacing the control valve of the motorised three-way valve.
Replacing the three-way valve
Step-by-step guide for replacing the three-way valve unit.
Checking the ERC/RC connections to the UBA
Verifying correct connections for external room controllers (ERC/RC) to the UBA.
Replacing the terminal strip
Instructions for replacing the terminal strip for cable connections.
Checking connections at the ERC or RC
Checking controller device connections and expected DC voltage.
Replacing the room-temperature control device
Procedure for replacing the room-temperature control device.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the 24S and is the answer not in the manual?
Questions and answers