IDEAL 61-495 Technical Manual
Hide thumbs Also See for 61-495:

Advertisement

IDEAL INDUSTRIES, INC.
TECHNICAL MANUAL
MODEL: 61-494
MODEL: 61-495
The Service Information provides the following information:
• Precautions and safety information
• Specifications
• Basic maintenance (cleaning, replacing the battery and fuses)
• Performance test procedures
• Calibration and calibration adjustment procedures
Form number: TM61494-5
Revision: 2. Date: Feb 2002
Form number TM61494-5
Rev 2 February 2002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 61-495 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
Precautions and Safety Information
General warnings and cautions for safe operation and handling of the multimeter.
The Symbols
Explanation of symbols used on the meter and within the manual for clarity.
Safety
Specific Precautions
Specific safety measures to prevent injury and damage to the product or connected items.
Specifications
General Specifications
Overall characteristics of the multimeter, including display and power source.
Voltage Specifications
Accuracy and range for DC and AC voltage measurements.
dBm / dBv Specifications
Specifications for decibel measurements in milliwatts and volts.
Current Specifications
Accuracy and range for DC and AC current measurements.
Resistance Specifications
Accuracy and range for resistance measurements across various ranges.
Capacitance Specifications
Accuracy and range for capacitance measurements in counts.
Continuity Check Specifications
Specifications for continuity threshold and indicator.
Diode Test Specifications
Specifications for test current and open circuit voltage for diode testing.
Peak Hold Specifications
Additional error specifications for the Peak Hold function.
Frequency Counter Specifications
Specifications for frequency counter range, resolution, accuracy, and sensitivity.
Duty Factor Specifications
Specifications for duty factor measurement range and accuracy.
Temperature Specifications
Accuracy and range for temperature measurements in Celsius.
Physical and Environmental Characteristics
Physical dimensions, weight, and environmental operating conditions.
Certifications and Compliances
EC Declaration of Conformity
Details on EC declaration of conformity for EMC and safety directives.
Basic Maintenance
Opening Meter Case
Step-by-step guide to opening the multimeter case for access.
Replacing the Battery
Procedure for replacing the 9V battery in the multimeter.
Testing Fuses (FS1 and FS2)
Procedure for testing the internal fuses FS1 and FS2.
Replacing Fuses
Instructions for replacing the multimeter fuses with correct ratings.
Cleaning
Instructions for cleaning the multimeter safely.
Input Terminals
Method for cleaning the input terminals to prevent false alerts.
Performance Tests
A Basic Operability Test
Basic test to check the multimeter's general functionality and fuse status.
Testing the Display
Procedure to test the multimeter's LCD display functionality.
Testing the Voltage Function
Verifying accuracy of AC and DC voltage measurements against specifications.
Testing Millivoltage (mV) Function
Verifying accuracy of AC and DC millivolt measurements.
Testing the PEAK HOLD Function
Checking the functionality of the Peak Hold feature.
Testing the Resistance Function
Verifying accuracy of resistance measurements across various ranges.
Testing the Capacitance Function
Verifying accuracy of capacitance measurements against specifications.
Checking the Diode Test Function
Checking the functionality of the diode test.
Testing the Milliamp (mA) Function
Verifying accuracy of AC and DC milliamp measurements.
Testing the Amp (A) Function
Verifying accuracy of AC and DC ampere measurements.
Testing the Frequency Function
Verifying accuracy of the meter's frequency measurement function.
Testing the Duty Factor Function
Verifying accuracy of the meter's duty factor measurement.
Testing the Temperature Function
Verifying accuracy of the meter's temperature measurement function.
Calibration
Calibrating the ACV Frequency Response
Procedure for calibrating the ACV frequency response.

Table of Contents