Olympus DP27 Instructions Manual
Olympus DP27 Instructions Manual

Olympus DP27 Instructions Manual

Microscope digital camera
Table of Contents

Advertisement

INSTRUCTIONS
DP22/DP27
MICROSCOPE DIGITAL CAMERA
This instruction manual is for the Olympus microscope digital camera DP22/DP27.
To obtain optimum performance of this camera and to ensure the safety, study this manual
thoroughly before operating the camera and keep it on hand during operation of the camera.
Keep this instruction manual in a safe place.
For details of products included in the configuration of this system, see page 16 of this
Optical Microscope Accessory
instruction manual.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DP27 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Introduction
Contents in this instruction manual
Details covered in this manual for the microscope digital camera DP22 and DP27.
Safety Precautions
CAUTION - Installation of microscope
Warning regarding microscope height to prevent overturning, do not exceed 1 meter.
CAUTION - Electric safety
Guidelines for using the correct power cord, grounding, and avoiding strong electromagnetic radiation.
CAUTION - Protection for electric shock
Avoid inserting tools into vents and keep cables away from hot lamp housing to prevent shock.
CAUTION - Protection for burns
Avoid touching the camera head for long hours due to heat generation to prevent low-temperature burns.
Handling Precautions
Intended use
Device is for capturing digital images, not for clinical diagnostic purposes.
Cautions in use
General handling advice for the precision instrument, including avoiding impact, water, and dust.
Image data
Information on potential data loss and compensation, emphasizing frequent backups.
System Compatibility
Restrictions in use
Table indicating compatible camera adapters with an "O" mark for usability and "X" for optical performance issues.
Issues related to specimen observation
Notes on flare, brightness differences, calibration, spot metering, electronic zoom, and resolution.
Frame rate and resolution
Tables showing maximum frame rates based on resolution and exposure time for DP22-CU and DP27-CU.
Auto white balance and flare reduction
Notes on auto white balance issues with low-contrast specimens and flare reduction methods.
Image acquisition limitations and monitor specifications
Limitations for dark specimens, color unevenness, and recommended monitor specifications for best color reproduction.
PC and Software
Recommended configurations
System requirements for PC hardware (CPU, RAM, HDD, Display, Drive) and software (OS, browser).
Trademark and Controller setup
Trademark information and initial setup procedures for the controller, including software activation.
HDD space and file management for controller
Advice on managing HDD space and not altering controller files to prevent software issues.
PC usage requirements
Guidelines for using desktop/laptop PCs, including HDD space and compliance with standards.
Maintenance and Storage
Cleaning lenses and parts
Instructions for cleaning lenses, filters, and other parts, including safety precautions for absolute alcohol.
Disposal and storage
Procedures for product disposal, handling smoke, preventing dew condensation, and proper storage.
System Diagram
Component connections
Diagram showing the connection of the camera head, adapter, interface cable, and PC.
Nomenclature of Respective Portions
Camera head and interface cable
Identification of key parts of the camera head and interface cable.
Assembly
Attaching camera head
Step-by-step instructions for attaching the camera head to the camera adapter and microscope.
Camera adapter magnification and parfocality
Information on camera adapter magnification effects on image area and parfocality adjustment.
Connecting interface cables
Detailed instructions for connecting the interface cable between the camera head and PC/controller.
Installation of Software
Software cellSens/OLYMPUS Stream installation
Guidance on installing cellSens/OLYMPUS Stream software, including prerequisites.
DP2-TWAIN driver
Information about the DP2-TWAIN driver and its availability for download.
Outline of Image Acquisition Procedures
Brightfield observation procedure
Flowchart illustrating the steps for acquiring images in brightfield observation.
Specifications
Camera specifications
Details on camera sensor size, pixels, scanning method, and filters for DP22-CU and DP27-CU.
Exposure control and image display
Specifications for exposure control, binning, live image display speed, color mode, white balance, and contrast.
Interface connectors and OS compatibility
Information on input/output connectors, applicable operating systems, dimensions, and power consumption.
Storage and operating environment
Environmental conditions for storage and operation, including temperature, humidity, and altitude.
Troubleshooting
Camera head and display issues
Troubleshooting steps for camera head not working or nothing shown on the display.
Live image display problems
Solutions for when the live image is not displayed, covering cable connections and microscope settings.
Image acquisition and brightness issues
Troubleshooting for inability to acquire still images and images being too bright.
Image darkness and color issues
Solutions for images being too dark and for strange colors in the image.
Image brightness and color difference
Addressing differences in brightness or color between image halves.
Image focus and vibration issues
Troubleshooting for images not being in focus and issues related to microscope/camera vibration.
Display and menu display problems
Solutions for display or menu characters not appearing correctly.
Repair request information
Information needed when requesting repairs, including product details and error codes.
Proper Selection of the Power Supply Cord
Specifications for power cord
Electrical specifications for selecting the correct power supply cord.
Table 1 Certified cord
List of agencies and certification marks for approved power supply cords.
Certification marks by country
Table showing certification marks from various countries and their corresponding agencies.
Table 2 HAR flexible cord
Approval organizations and cordage harmonization marking methods for HAR flexible cords.
HAR flexible cord marking details
Details on HAR flexible cord marking and requirements for UL and CSA certified cords.