Instruction Manual pH 11 & pH 110 Hand-held pH / mV / Temperature / RS 232 Meter 68X361301 Rev. 2 - 11/03 Technology Made Easy ...
Page 2
Authorised Distributor. It is recommended that all operators should read this manual prior to working with this instrument. Eutech Instruments / Oakton Instruments cannot accept any responsibility for damage or malfunction to the meter caused by improper use of the instrument.
TABLE OF CONTENTS INTRODUCTION............................1 DISPLAY & KEYPAD FUNCTIONS......................2 ..............................2 ISPLAY ..............................3 EYPAD PREPARATION ............................5 ........................5 NSERTING THE ATTERIES & E ......... 6 ONNECTING THE P LECTRODE EMPERATURE ROBE LECTRODE OLDER 3.2.1 To connect pH, ORP or ISE electrode .................... 6 3.2.2 To connect the temperature probe: ....................
Page 4
P2.0: V ..................38 IEWING REVIOUS ALIBRATION P3.0: V ....................... 39 LECTRODE 9.4.1 View pH Electrode Offset and Slope ..................... 39 9.4.2 View mV Offset (Only for pH 110) ....................40 P4.0 : A ............................ 41 P5.0 : R ..................... 42 ESET TO ACTORY EFAULT...
Instruction Manual CyberScan pH 11 / 110 INTRODUCTION Thank you for selecting the pH 11/110 meter. These meters are microprocessor- based instruments and are designed to be handy, capable of allowing one-hand operation. Each has a large custom dual LCD for clear and easy reading. It is a unique and intelligent instrument that has the capability to cater to the preferences of the discerning individual.
Instruction Manual CyberScan pH 11 / 110 DISPLAY & KEYPAD FUNCTIONS Display The LCD has a primary and secondary display. • The primary display shows the measured pH or mV values. • The secondary display shows the measured temperature. The display also shows error messages, keypad functions and program functions. Primary Display SETUP MEAS CAL R.mV...
Instruction Manual CyberScan pH 11 / 110 Keypad A large membrane keypad makes the instrument easy to use. Each button, when pressed, has a corresponding graphic indicator on the LCD (Figure 2 on previous page). Some buttons have several functions depending on its mode of operation. FUNCTION •...
Page 8
Instruction Manual CyberScan pH 11 / 110 HOLD HOLD MEAS ENTER MEAS ENTER SETUP MODE SETUP MODE Keypad for pH 11 meter Keypad for pH 110 meter Figure 2: pH 11 and pH 110 keypads...
Instruction Manual CyberScan pH 11 / 110 PREPARATION Inserting the Batteries This meter is packaged with 4 “AAA” alkaline batteries required for operation. To insert the batteries into the meter, follow the procedure outlined below. To open the battery compartment, press down the catch of the battery cover. See below.
Instruction Manual CyberScan pH 11 / 110 Connecting the pH Electrode Temperature Probe & Electrode Holder The pH 11/110 meter uses any standard pH, ORP, or Ion Selective Electrode (ISE) with a BNC connector. For Automatic Temperature Compensation (ATC), this meter requires a temperature probe with a phono-jack connector.
Instruction Manual CyberScan pH 11 / 110 3.2.2 To connect the temperature probe: The temperature probe (provided) uses a 2.5 mm phono jack to connect with the socket on the pH 11/110. Insert the jack fully into the socket (Figure Note: Calibrate your temperature probe when you replace the probe and when using a “3-in-One”...
Instruction Manual CyberScan pH 11 / 110 Align the flange of the second electrode holder with the slot of the first holder (Figure 8). Slide the flange of the second holder into the slot of the first holder until the tops of the holders are aligned and secure.
Instruction Manual CyberScan pH 11 / 110 Connecting the AC/DC Adapter Besides using four AAA-sized batteries as a power source, the pH 11/110 meter can also operate from the power mains using an AC/DC power adapter either at 120/220 VAC (sold separately). This is extremely useful if you have an A.C. power source available (e.g.
Instruction Manual CyberScan pH 11 / 110 3.4.1 RS232C Configuration The pH 110 meter has a 9 pin female RS232C connector with the following pin out: PIN NO. DESCRIPTION Transmit Data CTS (Clear to Send) GND (Ground) A one-to-one connection can be made with a 9 pin RS232C port of the computer. In case pH 110 meter’s output has to be sent to a 25 pin RS232C connector, the following cable configuration may be used: pH 110...
Instruction Manual CyberScan pH 11 / 110 CALIBRATION Important Information on Meter Calibration When you re-calibrate your meter, previous pH and Relative mV calibration points are replaced on a point by point basis. For example, if you previously calibrated your meter at pH 4.01, 7.00, and 10.01, and you have now re-calibrated at pH 7.00, the meter retains the old calibration data at pH 4.01 and pH 10.01.
Instruction Manual CyberScan pH 11 / 110 4.2.1 pH 11 meter calibration The pH 11 meter is capable of up to 5-point pH calibration to ensure accuracy across the entire pH range of the meter. You can select from the following buffer options: •...
Instruction Manual CyberScan pH 11 / 110 pH Calibration with ATC NOTE: We recommend that you perform at least 2-point calibration using standard buffers that bracket (one above and one below) the expected sample range. If necessary, press the MODE key to select pH mode.
Page 18
Instruction Manual CyberScan pH 11 / 110 Rinse the probe with de-ionised water or a rinse solution, and place it in the next pH buffer. READY 4.15 Follow steps 5 and 6 for additional calibration points. See Figure 12. 4 . 0 1 When all the calibration points set in the Unit Configuration Setup (see P1.3 Select Number HOLD...
Instruction Manual CyberScan pH 11 / 110 mV Calibration (Offset) (Only for pH 110) With pH 110 meter, you can perform a calibration or an offset of up to ±150 mV. Note: For Oxidation reduction Potential (ORP) or Redox measurements, an ORP MEAS electrode must be used.
Instruction Manual CyberScan pH 11 / 110 Temperature Calibration MEAS The temperature sensor is factory calibrated. Calibrate 7.16 the temperature probe only if you suspect temperature errors may have occurred over a long period of time or if °C 2 2 . 3 you have a replacement temperature probe.
Instruction Manual CyberScan pH 11 / 110 MEASUREMENT This meter is capable of taking measurements with automatic or manual temperature compensation. Automatic temperature compensation only occurs when temperature sensor is plugged into the meter. If there is no temperature sensor plugged into the meter, the default manual temperature setting is automatically 25.0 °C.
Instruction Manual CyberScan pH 11 / 110 Manual Temperature Compensation IMPORTANT: For manual compensation, you must disconnect the temperature probe. The [ATC] annunciator will disappear from the LCD. Switch the meter on. Press the MODE key to select pH mode. 25.0 Press CAL/MEAS...
Instruction Manual CyberScan pH 11 / 110 Taking Measurements Be sure to remove the electrode soaker bottle or protective rubber cap on the electrode before measurement. To take readings: Rinse the probe with de-ionised or distilled MEAS water before use to remove any impurities 8.23 adhering to the probe body.
Instruction Manual CyberScan pH 11 / 110 HOLD FUNCTION This feature lets you freeze the value of the pH, mV (or relative mV) and temperature readings for a delayed observation. HOLD can be used any time when in MEAS mode. hold measurement, press...
Instruction Manual CyberScan pH 11 / 110 MEMORY FUNCTION The memory function is available in both pH 11 and pH 110 meters. These meters store data in sets: MEAS 8.23 READY • pH and temperature °C 2 1 . 3 •...
Instruction Manual CyberScan pH 11 / 110 Memory Recall MEAS This function recalls the previous readings stored in the 7.16 memory. only access from measurement mode. Memory recall is in “Last In First °C 2 2 . 3 Out” order. To recall readings: Press the MR/▼...
Turn on pH 110 meter and note the following: f. For printer, ensure it is powered on and paper is loaded. g. For computer, ensure that Eutech Instruments’ CyberComm Portable Data Acquisition Software is installed and activated. See section 10.3 - Running CyberComm Portable on page 51.
Page 28
Instruction Manual CyberScan pH 11 / 110 • dAt / StO: Print Stored Data from Memory. This simply dumps all data stored in memory. You cannot print data from selected memory locations. See Figure below. From pH or mV measurement mode. HOLD ENTER HOLD...
Instruction Manual CyberScan pH 11 / 110 MEAS 8.2.1 Print Current Data Manually 6 . 5 5 READY To manually print any data that is currently being measured: 2 3 . 4 °C From measurement mode, press HOLD key to freeze reading.
Instruction Manual CyberScan pH 11 / 110 "MEM" annunicator will keep flashing during measurement mode & data will be printed on From measurement mode pre-set timed interval. To stop, press PRINT key MEAS 4 . 7 5 READY 2 1 . 0 °C HOLD Print on set timed...
Page 31
Instruction Manual CyberScan pH 11 / 110 Press HOLD/ENTER key. The “Prn” primary display will flash until all data is printed. To stop printing, press PRINT key and exit to measurement mode. See Figure 26. NOTE: All stored memory will remain in the meter after printing. "Prn"...
Page 32
2 2 . 4 Figure 27: Print based on selected stored data from memory For more information about Eutech Instruments’ CyberComm Portable Data Acquisition Software programme, see section 10 - CYBERCOMM PORTABLE DAS (Only for pH 110) on page 45.
Instruction Manual CyberScan pH 11 / 110 ADVANCED SETUP FUNCTIONS The advanced setup mode lets you customised your meter’s preferences and defaults. The pH 11 and pH 110 meters feature different sub groups that organise all setup parameters. The sub-groups are: For pH For mV P1.0...
Page 34
Instruction Manual CyberScan pH 11 / 110 From pH measurement mode From mV measurement mode SETUP SETUP SETUP SETUP C O F C O F P 1 . 0 P 1 . 0 SETUP SETUP This program is C A L E L E available only in PH 110 but...
Instruction Manual CyberScan pH 11 / 110 Advanced SETUP Mode Overview Press the SETUP key to enter Setup mode. Press the MI/▲ and MR/▼ keys to scroll through the sub groups. 9.1.1 pH Setup mode P1.0: Unit Configuration SETUP P1.1 Ready indicator (On, Off or Auto Hold) C O F P1.2...
Instruction Manual CyberScan pH 11 / 110 9.1.2 mV Setup mode P1.0: Unit Configuration SETUP P1.1 Ready indicator (On, Off or Auto Hold) C O F P1.4 Select °C or °F temperature units (pH 110 only) P 1 . 0 P3.0: View Electrode Data (pH 110 only) SETUP P3.1...
Instruction Manual CyberScan pH 11 / 110 P1.0 : Unit Configuration This subgroup program allows customising the meter to SETUP your specific needs. You can program the meter to: c o f Select READY function ON or OFF (pH 110 allows you an additional feature of switching the p 1.0 AUTO HOLD function ON or OFF)
Instruction Manual CyberScan pH 11 / 110 9.2.1 P1.1: READY Indicator and Auto Hold function Program P1.1 lets you select “READY indicator on” to indicate when the reading is stable, or select “READY indicator off” for faster meter response. In the pH 110 meter, program P1.1 also lets you switch the auto hold function on or off.
Instruction Manual CyberScan pH 11 / 110 9.2.3 P1.3 Select Number of pH Calibration Points Program P1.3 lets you select the number of calibration points that appear in pH calibration mode: 2, 3, 4, or 5 (or 6 with DIN buffer option). This lets the meter scroll through the calibration points more quickly if you regularly calibrate at less than 5 points.
Instruction Manual CyberScan pH 11 / 110 9.2.4 P1.4 Select °C or °F Temperature Units Available in pH 110 meter only The pH 110 meter lets you select between °C and °F SETUP units for temperature readings. From measurement mode p 1.4 °C Press SETUP key to enter Set Up mode.
Instruction Manual CyberScan pH 11 / 110 P2.0: Viewing Previous Calibration Data SETUP This mode lets you recall previous calibration data, c a l which helps you know when to re-calibrate your meter. This is a “view only” mode. p 2 . 0 From measurement mode: Press the SETUP key to enter Set up mode.
Instruction Manual CyberScan pH 11 / 110 P3.0: View Electrode Data Program 3 has two “view only” options that let you check the electrode parameters for diagnostic purposes. • From pH measurement mode, you can view the electrode’s offset and slope values.
Instruction Manual CyberScan pH 11 / 110 9.4.2 View mV Offset (Only for pH 110) If you are in mV measurement mode, the display shows the relative mV offset. You can adjust the relative mV offset in relative mV calibration mode. See section 4.4 - mV Calibration (Offset) on page 15.
Instruction Manual CyberScan pH 11 / 110 P4.0 : Auto-Off In Program P4.0 you can activate the AUTO-OFF option to automatically power off the instrument 20 minutes after the last key selection. This feature is useful for conserving battery power. Under default conditions, the instrument has this option activated.
Instruction Manual CyberScan pH 11 / 110 P5.0 : Reset to Factory Default This mode lets you reset all parameters to factory default settings. There are two levels of reset: SETUP • Calibration Reset: Reset only the calibration values. This clears all previous calibrated P 5 .
Instruction Manual CyberScan pH 11 / 110 NOTE: Calibration reset is independent for each measurement parameter. That is: • From pH mode, calibration reset will only erase pH calibration values; and • From mV mode, calibration reset will only erase mV calibration values.
Instruction Manual CyberScan pH 11 / 110 P 6.0: Memory Clear (CLr) Use this parameter to clear all memory values when you need to store a new series of values. This lets you avoid confusing the old values with the new ones. NO is the default setting.
Connecting communication RS232C cable 10.2 Loading CyberComm Portable DAS Figure 41: Insert Eutech Instruments' CD-ROM containing Data Acquisition Software (DAS) into your CD-ROM drive. It will Auto Run and let you start loading the software by displaying the screen as in Figure 44.
Page 50
Instruction Manual CyberScan pH 11 / 110 Figure 42: Click on 'Browse' button and locate CD-ROM drive Figure 43: Locate the CyberComm Portable Setup program in the CD-ROM under "Eutech DAS" directory.
Page 51
Instruction Manual CyberScan pH 11 / 110 Figure 44: Select ‘Portable Meters’ directory to go to CyberComm Portable. Figure 45: Open ‘CyberComm Portable’ to enter to the Setup program.
Page 52
Instruction Manual CyberScan pH 11 / 110 Figure 46: Select "SETUP.EXE" program and click the OPEN button Figure 47: InstallShield Wizard dialog box appears. Figure 48: Click on Next button...
Page 53
Instruction Manual CyberScan pH 11 / 110 Figure 49: Key in your name and company name and click NEXT button Figure 50: To select another Destination Directory to install the program, click on BROWSE button. Otherwise, click NEXT button.
Page 54
Instruction Manual CyberScan pH 11 / 110 Figure 51: Creating a new program folder. Click on NEXT button. Figure 52: Click on NEXT button.
Instruction Manual CyberScan pH 11 / 110 Figure 53: The CyberComm Portable DAS program is fully installed. Click on FINISH button to end installation. 10.3 Running CyberComm Portable Before running the DAS program, please ensure that the RS232 cable is connected between the computer’s serial port and the meter’s port.
Instruction Manual CyberScan pH 11 / 110 Figure 55: The opening screen will appear as above 10.3.1 Buttons & Check-Box • Enable Connection - Click this button to enable communication between meter and computer. • Clear Readings - To clear all data and start all over again. •...
Instruction Manual CyberScan pH 11 / 110 Figure 56: Under File Menu setting, you can change various parameters. Under ABOUT menu, details of Eutech Instruments' contact information, email address and updates are shown. 10.3.2 Menu • Communication Settings - To set communication port number, baud rate speed, parity and stop bits protocol.
Instruction Manual CyberScan pH 11 / 110 Figure 57: Communication Settings for computer's Com port. It must match with COM port settings on CyberScan pH 110 meter. Please refer to Section 8.1 Using pH 110 Meter With Printer or Computer on page 23 for the settings.
Instruction Manual CyberScan pH 11 / 110 10.4 Capturing And Printing Data Into Computer Using Data Acquisition After matching the Communication Settings between your computer using Data Acquisition program and the pH 110 meter, you can now capture data into your computer for analysis and storage purposes.
Instruction Manual CyberScan pH 11 / 110 10.5 Trouble-shooting Guide Problem: Unable to PRINT When press PRINT key on pH 110 meter, nothing is printed. POSSIBLE CAUSES SOLUTIONS You have not "ENABLE CONNECTION" in Click on "ENABLE CONNECTION" in the the Data Acquisition program.
Instruction Manual CyberScan pH 11 / 110 ELECTRODE CARE 11.1 Electrode Maintenance pH electrodes are susceptible to dirt and contamination and need to be cleaned regularly depending on the extent and condition of use. 11.1.1 Storage The best results, always keep the pH bulb wet, preferably in electrode storage solution or pH 4 buffers with 1/100 part of saturated KCl.
Instruction Manual CyberScan pH 11 / 110 rejuvenate it. (See section 11.4 on Rejuvenation Procedure). 11.2 Electrode Cleaning Electrodes that are mechanically intact can be restored to normal performance by one or combination of the following procedures. a) Salt deposits: Dissolve the deposit by immersing the electrode in tap water for ten to fifteen minutes.
Instruction Manual CyberScan pH 11 / 110 11.4 Rejuvenation Procedure 1. Dip and stir the electrode in freon or alcohol for 5 minutes. 2. Leave the electrode in tap water for 15 minutes. 3. Dip and stir the electrode in concentrated acid (e.g. HCl, H2SO4) for 5 minutes.
Instruction Manual CyberScan pH 11 / 110 ERROR MESSAGES The following table provides a guideline to enable diagnosis of possible problems indicated by the messages generated by the meter. The table also provides possible solutions to the problems encountered. ERROR MESSAGE INDICATES POSSIBLE CAUSE CORRECTIVE...
Instruction Manual CyberScan pH 11 / 110 TROUBLE-SHOOTING PROBLEM PROBABLE CAUSE REMEDIAL ACTION Nothing is displayed when Batteries not in place. Insert batteries. the ON/OFF key is Batteries (+ & - poles) not Re-insert batteries in the selected. in correct polarity. correct polarity.
Instruction Manual CyberScan pH 11 / 110 INFORMATION ON pH MEASUREMENT & ELECTRODE The previous sections of this manual describe the various features of the instrument and practical aspects of its operation. This section provides a general description of pH measurement principles. It also provides tabulations of pH buffer changes with temperature.
Instruction Manual CyberScan pH 11 / 110 14.1.3 pH and Temperature The electromotive force generated in the glass electrode varies with the temperature of the solution. As a result the response of the pH electrode is subjected to variations in temperature. Automatic Temperature Compensation compensates for this variance.
Instruction Manual CyberScan pH 11 / 110 14.3 Standard pH Buffers The following table shows the various pH values at different temperature of the solution during calibration. Temperature pH 1.68 pH 4.01 pH 7.00 pH 10.01 pH 12.45 (ºC) (oxalate) (phthalate) (neutral (carbonate)
Instruction Manual CyberScan pH 11 / 110 LIST OF ACCESSORIES 15.1 Replacement Meter and Meter accessories Eutech Instruments Item Eutech Instruments Order Code CyberScan pH 11 Portable pH/mV Meter with 2 electrode holders EC-PH11/01 15X000700, temperature probe EC-PH5-TEM01P CyberScan pH 110 Portable pH/mV/RS232 Meter with 2 electrode holders EC-PH110/01 15X000700, PC-based DAS, RS232C cable &...
Instruction Manual CyberScan pH 11 / 110 FACTORY DEFAULT SETTINGS 16.1 pH 11 Factory Default Settings PROGRAM FUNCTION PARAMETER PARAMETER DEFAULT OPTING KEYS OPTIONS SETTING P 1.0 Unit Configuration Parameter Title Parameter Title Only Only P 1.1 Ready Indicator MI/▲; MR/▼ ON ;...
Instruction Manual CyberScan pH 11 / 110 16.2 pH 110 Factory Default Settings PROGRAM FUNCTION PARAMETER PARAMETER DEFAULT OPTING KEYS OPTIONS SETTING P 1.0 Unit Configuration Parameter Title Parameter Title Only Only P 1.1 Ready Indicator MI/▲; MR/▼ ON ; OFF, HOLD P 1.2 Select pH buffer option MI/▲;...
For your protection, items must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Eutech Instruments/ Oakton Instruments will not be responsible for damage resulting from careless or insufficient packing. A restocking charge will be made on all unauthorised returns.
Page 76
For more information on Eutech Instruments/ Oakton Instruments’ products, contact your nearest distributor or visit our website listed below: Oakton Instruments Eutech Instruments Pte Ltd Distributed by: P.O Box 5136, Blk 55, Ayer Rajah Crescent, Vernon Hills, IL60061, USA #04-16/24 Singapore 139949...
Need help?
Do you have a question about the CYBERSCAN PH 110 PHMVRS232 METER and is the answer not in the manual?
Questions and answers