Advertisement

IS3480 QuantumE
QuantumT 3580
Fusion 3780
Orbit 7120/7180
Solaris 7820

Quick Start Guide

Aller à
www.honeywellaidc.com
Vai a
www.honeywellaidc.com
Gehe zu
www.honeywellaidc.com
Ir a
www.honeywellaidc.com
Para Português, acesse www.honeywellaidc.com.br.
Перейти на русскоязычный сайт www.honeywellaidc.com.
Pro češtinu jdi na www.honeywellaidc.com.
Pre slovenčinu choď na
日本語 :
www.honeywellaidc.com
如要到中国 www.honeywellaidc.com(简体) 。
한글
www.honeywellaidc.com
pour le français.
per l'italiano.
für Deutsch.
para español.
www.honeywellaidc.com
をご覧ください。
로 이동합니다

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fusion 3780 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Getting Started
Scanner Host Ports
Displays images and names of various scanner models.
Connecting the Scanner
USB Connection
Illustrates how to connect the scanner using a USB cable to a host.
Serial (RS232) Connection
Illustrates how to connect the scanner using a Serial (RS232) cable.
Keyboard Wedge Connection
Illustrates connecting the scanner via the Keyboard Wedge interface.
Interface Selections - USB
USB Interface Options
Configures USB emulation modes like Keyboard, Serial, and IBM/OEM.
Keyboard Wedge Configuration
Keyboard Country Selection
Selects keyboard country templates for specific language layouts.
ALT Mode Configuration
Enable/Disable 3-digit ALT Mode
Enables or disables the 3-digit ALT Mode for extended ASCII data.
Enable/Disable 4-digit ALT Mode
Enables or disables the 4-digit ALT Mode for extended ASCII data.
RS232 Communication Commands - Part 1
Handshaking Settings
Configures RS232 handshaking options like RTS/CTS and XON/XOFF.
Data Bits and Stop Bits
Sets data bits and stop bits for RS232 communication.
Power Save Modes - Part 1
Blink Power Save Mode
Activates the Blink power save mode for the scanner.
Laser Off Power Save
Configures power save mode with the laser turned off.
RS232 Communication Commands - Part 2
Parity Settings
Configures parity settings for RS232 communication.
Stop Bit Settings
Configures the stop bit setting for RS232 communication.
Power Save Modes - Part 2
Laser and Motor Off Power Save
Configures power save mode with laser and motor turned off.
Power Save Mode Always
Sets the scanner to always be in power save mode.
Power Save Mode Never
Disables all power save modes for the scanner.
Host Scanner Commands - Part 1
Enable/Disable Scanning
Controls scanner enable/disable based on host ASCII commands.
Host Scanner Commands - Part 2
Activate DC2 Character
Initiates scanning upon receipt of a DC2 character.
Transmit Serial Number
Transmits the scanner's serial number.
LED Options
Laser LED Off
Turns off the Laser LED while scanning bar codes.
Scan LED Off
Turns off the Scan LED while scanning bar codes.
Prefix Settings - Part 1
STX Prefix On/Off
Adds or removes the STX start-of-text character as a prefix.
AIM ID Prefix On/Off
Adds or removes AIM ID identification characters as a prefix.
Prefix Settings - Part 2
NCR Prefix On/Off
Adds or removes NCR identification characters as a prefix.
Nixdorf Prefix On/Off
Adds or removes Nixdorf identification characters as a prefix.
Suffix Settings - Part 1
CR Suffix On/Off
Adds or removes Carriage Return as a suffix.
LF Suffix On/Off
Adds or removes Line Feed as a suffix.
Suffix Settings - Part 2
Tab Suffix On/Off
Adds or removes Tab character as a suffix.
ETX Suffix On/Off
Adds or removes ETX end-of-text character as a suffix.
User Configurable Prefix/Suffix - Setup
Enter/Exit Programming
Enters/exits programming mode for custom prefix/suffix setup.
User Configurable Prefix/Suffix - Prefix Options
Configurable Prefix #1
Configures the first user-defined prefix.
Configurable Prefix #2
Configures the second user-defined prefix.
User Configurable Prefix/Suffix - Suffix Options
Configurable Suffix #1
Configures the first user-defined suffix.
Configurable Suffix #2
Configures the second user-defined suffix.
Supplements
2 Digit Supplements On/Off
Enables or disables 2-digit bar code supplements.
5 Digit Supplements On/Off
Enables or disables 5-digit bar code supplements.
977 (2 Digit) Supplement Required
977 Supplements On/Off
Manages 2-digit supplements for EAN-13 codes starting with 977.
UPC/EAN Formatting - Conversion
Convert UPC-A to EAN-13
Converts UPC-A barcodes to EAN-13 format by adding a leading zero.
UPC/EAN Formatting - UPC-E Options
Transmit Lead Zero on UPC-E
Transmits a leading zero before UPC-E barcodes.
Don't Transmit Lead Zero on UPC-E
Does not transmit a leading zero before UPC-E barcodes.
Transmit UPC-A Number System
Transmit UPC-A Leading Digit
Transmits the UPC-A leading digit with barcode data.
Don't Transmit UPC-A Number System
Transmits UPC-A data without the leading digit.
Expand UPC-E to 12 Digits
Expand UPC-E to 12 Digits
Expands UPC-E codes to the 12-digit UPC-A format.
Don't Expand UPC-E to 12 Digits
Prevents expansion of UPC-E codes to 12 digits.
Code 39 Full ASCII
Code 39 Full ASCII On
Enables full ASCII interpretation for Code 39 barcodes.
Code 39 Full ASCII Off
Disables full ASCII interpretation for Code 39 barcodes.
Check Digits - UPC-A
Transmit UPC-A Check Digits
Specifies transmission of UPC-A check digits.
Check Digits - UPC-E & Disable
Transmit UPC-E Check Digits
Specifies transmission of UPC-E check digits.
Don't Transmit UPC-A Check Digits
Prevents transmission of UPC-A check digits.
Don't Transmit UPC-E Check Digits
Prevents transmission of UPC-E check digits.
GS1 Symbology - Databar 14
GS1 Double Border Required
Enables GS1 Double Border for GS1 DataBar symbologies.
Enable GS1 Databar 14
Enables GS1 Databar 14 symbology.
Disable GS1 Databar 14
Disables GS1 Databar 14 symbology.
GS1 Symbology - Limited
Enable GS1 Limited
Enables GS1 Limited symbology.
Disable GS1 Limited
Disables GS1 Limited symbology.
Host Configurations
Verifone® Ruby Terminal Defaults
Sets scanner to Verifone Ruby Terminal default configuration.
Gilbarco® Terminal Defaults
Sets scanner to Gilbarco Terminal default configuration.
Wincor Nixdorf Terminal Defaults
Sets scanner to Wincor Nixdorf Terminal default configuration.
Miscellaneous Settings
Minimum Symbol Length
Sets the minimum number of characters for non-UPC/EAN barcodes.