Offset adjust

These settings are used to set up offset values for the Depth and
Spread sensors.
To access the parameters, press the MENU button to open the
main menu. Then, open the Setup menu (4) and select Sensor
alarm/calibration (4). When the dialogue opens, press the
GAIN+ button four times to open the Offset adjust dialogue.
When accessed, this dialogue will only display the Depth and
Spread sensors currently configured. Offset adjustments can be
only be made on the listed sensors. Enter a negative or positive
value to decrease or increase all readings from the chosen
sensor.
Related topics
How to define sensor offsets, page 66
PI Depth sensor, page 124
PS Depth sensor, page 129
PI Spread sensor, page 143