Page 17
SIMRAD MENU STND ZOOM B-LCK A-SCP GAIN - GAIN + ✸ EVENT SIMRAD SIMRAD LCD display options Window 3 Window 4 Navigation Echo sounder colour LCD ...
Page 18
@IU@S Turns the menu bar on/off. Turns the cursor on/off. Exits any data display without taking Opens for insertion and confirms action. the editing of data. VGUD9DS@8UDPIÃ7VUUPI moves Changes between available values, the cursor horizontally by pressing on scales and ranges, (-) minus reduces its left or right side and vertically by and (+) increases the graduation.
Page 32
Status Log 1 Log 2 No valid POS 0.0nm 0.0nm LAT 56å53.000 N LON 9å50.000 E Speed Course Depth *.* Kn * å *.* m Local date Water temp. Local time 0-0-0000 *.* C å 00:00:00 5288) ...
Page 40
*.*åC *.* kn *.* m 200kHz HIGH LONG *.*åC *.* kn *.* m 200kHz HIGH LONG ...
Page 41
Transducer depth below surface: 0.0 m Keel depth below surface 0.0 m Display: DEPTH BELOW SURFACE Alarm for fish: Strength: 30dB OFF Depth for fish: min: 10 m max: 100 m Depth alarm maximum: 100 m OFF Depth alarm minimum: 10 m OFF Transmitter: AUTO...
Page 43
Speed alarm minimum: 0.0 kn OFF Depth in: METERS Distance in: NAUTICAL MILES Speed in: KNOTS Temperature in: DEGREE CELSIUS Software version: PI30 0.12 DSP: 0.00. MC: 0.00 WIN change interval: 5 sec. MANUAL Display test in: English GB 5300) ...
Page 44
Interface setup NMEA: Input pin (3,4): NMEA0183 Position: GLL ON Course: VTG ON Speed: VTG ON Navigation (APB, RMB and XTE): Water temperature: MTW ON Output pin (1,2): NMEA0183 DBK ON DBS OFF DBT OFF DPT ON MTW ON VHW ON Output pin (1,2): DATA FROM DSP Configuration (PSIMP,C):...
Page 45
Speed alarm, units & language Interface setup NMEA Interface setup remote/alarm Sensor alarm/calibration Sensor config & receiver setup Display colour Master reset Interface setup remote/alarm: Input pin (3,4): NMEA0183 Position: GLL OFF Course: VTG OFF Speed: VTG OFF Navigation (APB, RMB and XTE): Water temperature: MTW OFF...
Page 47
Depth 1: min: 0 m OFF. Max: 300 m OFF Depth 2: min: 0 m OFF. Max: 300 m OFF Depth 3: min: 0 m OFF. Max: 300 m OFF Calibration: Offset: D1:0.0 m D2:0.0 m D3:0.0 m 5310) ...
Page 51
Speed alarm, units & language Interface setup NMEA Interface setup remote/alarm Sensor alarm/calibration Sensor config & receiver setup Display colour Master reset Text: Background: SDW1 SDW2 SDW3 Data cursor: Menu text: Menu background: Menu text highlight: Menu highlight: Menu frame: Menu example: Echogram background: Depth sensor marker:...
Page 60
Status Log 1 Log 2 No valid POS 0.0nm 0.0nm LAT 56å53.000 N LON 9å50.000 E Speed Course Depth *.* Kn * å *.* m Local time Local date Water temp. 0-0-0000 *.* C å 00:00:00 5288) ...
Page 69
*.*åC *.* kn *.* m 200kHz HIGH LONG ...
Page 70
*.*åC *.* kn *.* m 200kHz HIGH LONG ...
Page 71
*.*åC *.* kn *.* m 200kHz HIGH LONG Transducer depth below surface: 0.0 m Keel depth below surface 0.0 m Display: DEPTH BELOW SURFACE Alarm for fish: Strength: 30dB OFF Depth for fish: min: 10 m max: 100 m Depth alarm maximum: 100 m OFF Depth alarm minimum:...
Page 73
Speed alarm minimum: 0.0 kn OFF Depth in: METERS Distance in: NAUTICAL MILES Speed in: KNOTS Temperature in: DEGREE CELSIUS Software version: PI30 0.12 DSP: 0.00. MC: 0.00 WIN change interval: 5 sec. MANUAL Display test in: English GB 5300) ...
Page 74
Interface setup NMEA: Input pin (3,4): NMEA0183 Position: GLL ON Course: VTG ON Speed: VTG ON Navigation (APB, RMB and XTE): Water temperature: MTW ON Output pin (1,2): NMEA0183 DBK ON DBS OFF DBT OFF DPT ON MTW ON VHW ON Output pin (1,2): DATA FROM DSP...
Page 75
Interface setup remote/alarm: Input pin (3,4): NMEA0183 Position: GLL OFF Course: VTG OFF Speed: VTG OFF Navigation (APB, RMB and XTE): Water temperature: MTW OFF Interface setup alarm: Output pin (5,2): ALARM ON Alarm stand-by level:...
Page 76
1RWH Depth 1: min: 0 m OFF. Max: 300 m OFF Depth 2: min: 0 m OFF. Max: 300 m OFF Depth 3: min: 0 m OFF. Max: 300 m OFF Calibration: Offset: D1:0.0 m D2:0.0 m D3:0.0 m 5310)
Page 77
1RWH Sensor 1: DEPTH - Channel: Sensor 2: DEPTH - Channel: 12 Sensor 3: DEPTH - Channel: 22 Hydr. audio: OFF Volume: AGC: Manual gain: 0 dB MP filter: MPF level: 42 dB Max shooting speed: 5 kn Detection threshold (DT): 8 dB Sensor filter: Time:...
Page 142
E Simrad AS Simrad AS Strandpromenaden 50 Box 111 N-3191 Horten Telephone: +47 33 03 40 00 Facsimile: +47 33 04 29 87 A L W A Y S A T T H E F O R E F R O N T O F T E C H N O L O G Y...
Need help?
Do you have a question about the PI30 and is the answer not in the manual?
Questions and answers