Download Print this page

zeeltronic PDCIS-01T User Manual

Programmable dc-cdi ignition

Advertisement

Quick Links

www.zeeltronic.com
info@zeeltronic.com
updated 06.06.2013
program version: 20.130410
PDCIS-01T PROGRAMMABLE DC-CDI IGNITION
PDCIS-01T is single channel DC-CDI with 2 switchable ignition maps.
TECHNICAL DATA
Limit values:
- minimum revs
- maximum revs
- minimum supply voltage
- maximum supply voltage
- max idle current draw
- constant output energy from idle to 11000 RPM
- output energy at 15000 RPM
- output energy at 20000 RPM
Circuit is protected against reverse supply voltage (wrong connection).
Features:
- fast power-up (also starts only with condenser)
- full power starting spark energy already at 8Volts power supply
- one isolated input for magnetic pickup
- store and load function for two ignition curves
- external switch for changing ignition map while riding
- soft rev limit (three stage rev limit)
- easy and fast programming on the field, via hand held programmer and PC
- programming while machine running - you can immediately see effects
- each curve can be set in 4 to 12 curve points
- signal delay compensation
- instant monitoring of rev's and angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)
Very important!
Resistor spark plugs must be used, because they reduce electromagnetic disturbances.
USER MANUAL
- 1 -
200 RPM
20000 RPM
9 Volts
16 Volts
30 mAmp
>51mJ
>38mJ
>30mJ

Advertisement

loading
Need help?

Need help?

Do you have a question about the PDCIS-01T and is the answer not in the manual?

Questions and answers

Summary of Contents for zeeltronic PDCIS-01T

  • Page 1 06.06.2013 program version: 20.130410 USER MANUAL PDCIS-01T PROGRAMMABLE DC-CDI IGNITION PDCIS-01T is single channel DC-CDI with 2 switchable ignition maps. TECHNICAL DATA Limit values: - minimum revs 200 RPM - maximum revs 20000 RPM - minimum supply voltage...
  • Page 2 HOW TO ENTER MENU PDCIS must be connected to power supply. Connect programmer to PDCIS and wait few seconds for activation of programmer and then press enter. With pressing + or - you can move through menu and with pressing enter you can choose. You can exit menu with choosing Exit.
  • Page 3 Important! To avoid wrong processing, don't make unreasonable curve course. Every time you make any changes to ignition curve, it is automatically saved to #0 position. Then you can save it to any other position number from #1 to #2. Curve Example with six curve points: 5.1.
  • Page 4 Set ADVANCE With this setting is possible to advance or retard whole ignition curve. When setting is positive then ignition curve is advanced and when setting is negative than ignition curve is retarded. With Advance 0.0deg, ignition curve is unchanged. Enter menu and move to Advance with pressing + , or - and then press enter .
  • Page 5 Set PULSES PER REV It is number of pulses per rev from pickup coil and is important for correct rev reading. Set 1 for single cylinder engines. Set 2 for all twins with wasted spark ignition system. Enter Set Ign. menu and move to Pulses Per Rev with pressing + , or - and then press enter.
  • Page 6 Set "only [+] signal" when using custom, or modified trigger rotor, or upgrade from static ignition timing CDI. Set "[+] and [-] signal" when using original trigger rotors, or flywheels. First ignition point should be programmed somewhere between 1000-2000rpm. IGNITION TEST Spark execution test without running engine.
  • Page 7 MONITORING Connect programmer to PDCIS and wait few seconds for activation of programmer. Fist information displayed on the programmer is software version. With programmer you can watch revs, calculated advance ignition angle, selected ignition curve, TPS position...depends on setting in the menu. Information! You can connect or disconnect PDCIS unit from programmer any time you want, without any harm.