Focus ERGOFOCUS GAS Installation, Servicing & User Instructions

Advertisement

Quick Links

CREATE BEYOND CONVENTION
ERGOFOCUS GAS
INSTALLATION
SERVICING AND USER
INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ERGOFOCUS GAS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Focus ERGOFOCUS GAS

  • Page 1 CREATE BEYOND CONVENTION ERGOFOCUS GAS INSTALLATION SERVICING AND USER INSTRUCTIONS...
  • Page 2: Table Of Contents

    TECHNICAL DETAILS This appliance is designed for use with the type of gas and pressure indicated on the appliance nameplate. USER INSTRUCTIONS This manual covers the following devices: - Ergofocus gas BATTERY TYPE OPERATING INSTRUCTIONS MANUAL TURN OFF CLEANING AND MAINTENANCE...
  • Page 3: General Information

    General Information Before installation, ensure that the local distribution conditions (identification IMPORTANT SAFETY NOTICE of the type of gas and pressure) and the adjustment of the appliance are compatible. The technical specification of this appliance is given on the rear This appliance has a ceramic Fire-bed arrangement;...
  • Page 4: Installer Information

    Installer information VENTILATION Safety clearance distances from combustible materials. This product is rated in excess of 7kW, and it is a legal requirement to have 100cm2 of ventilation if the input is in excess of 7kW. Thus 100cm2 of ventilation is required. Any air supply shall be in accordance with national regulations.
  • Page 5: Installing The Appliance

    Installer information INSTALLING THE APPLIANCE A. PLATE TYPES Standard plate Oblique plate...
  • Page 6 Installer information B. FIREPLACE INSTALLATION Arrière Back 80 mm 100 mm Ø350 mm mini Avant Front PLT waiting en attente...
  • Page 7 Installer information Reversed collier collar obligatoire mandatory adjustable element élément réglable 9 screws M8 Welding SOUDURE DU CONDUIT...
  • Page 8 Installer information 5 screws FXC M5x12 4 screws TBHC M5x8 DUCT MARKING TO BE MARQUAGE DU CONDUIT POSITIONED AT THE FRONT A POSITIONNER OF THE FIREPLACE A L’AVANT DU FOYER...
  • Page 9 Installer information n°13 3 nut M8 See connection details (steps 17,18,19)
  • Page 10 Installer information Detail of PLT stainless steel gas hose connection (BANIDES) Insert pipe into fitting as Cut the PLT pipe with a pipe far as it will go. Push until cutter the stainless steel part disappears. Strip the first 6 waves with a safety knife.
  • Page 11 Installer information n°24 Tightening torque = 30 N.m 1000 mm maxi 4 screws FXC M5x12 See connection details on page 10 (steps 19, 20 ,21) alimentation gaz (non fourni) Tightening Joint Seal torque (supplied) (fourni) = 30 N.m...
  • Page 12 Installer information 5 screws FXC M5x12 4 screws TBHC M5x8...
  • Page 13: Testing And Commissioning

    Installer information e fuite de gaz depuis l’al TESTING AND COMMISSIONING To carry out these operations, you must first remove the casings as described in steps 9 and 10 on page 8. A. LEAK TEST Test burner pressures, as described on page 18 (pressures on page 21). Leak test Test d’étanchéité...
  • Page 14 Installer information B. PURGE PROCEDURE Gas circuit purging is not possible when the system is equipped with the exodraft extractor option. Set the knob to MAN. Keep valve depressed. Hold the valve down and use a lighter to check for gas at When pilot is lit, release valve.
  • Page 15: Arranging The Ceramic Fire-Bed

    Installer information ARRANGING THE CERAMIC FIRE-BED Only the ceramics supplied with this appliance are to be used. The ceramics must be laid only as shown on the following pages. Replacement parts including mat are avaible from your dealer, but sould only be installed by a qualified installation engineer. IDENTIFICATION OF INSTALLATION KIT PARTS : mini chips grey vermiculite black...
  • Page 16 Installer information Scatter the grey chips making sure that no grey chips Lay Log 2 as shown above. enter the Pilot area. Lay Log 1 as shown above. Lay log 3as shown above. Lay Log 4 as shown above. Lay Log 5 as shown above. Lay Log 6 as shown above.
  • Page 17 Installer information Lay Log 7 as shown above. Lay Log 8 as shown above. Lay Log 9 as shown above. Scatter black vermiculites, black small pebbles. The layout is now complete. Ensure that the Pilot area is still left clear, and check the correct lighting of the Pilot and that the Pilot cross lights to the main burner smoothly.
  • Page 18: Burner Pressure

    Installer information BURNER PRESSURE TESTING FOR SPILLAGE Remove the screw from the pressure test point. Close all doors and windows to the room containing the appliance. Let the The pressure test point is situated on the side of the gas control. fire run on HIGH for ten minutes.
  • Page 19: Servicing Instructions

    Installer information SERVICING INSTRUCTIONS TROUBLESHOOTING This appliance must be serviced at least annually by a qualified engineer. Pilot sparks but does not light – No gas to fire, check isolators are open. Ensure that the fire is fully cold before attempting service. A suggested Pipework blockage, clean out.
  • Page 20: Countries Of Destination

    Installer information COUNTRIES OF DESTINATION The following tables gives detail of the Countries that these appliances are approved for use within. The tables following immediately on give the technical characteristics of the appliances. Contry Natural AT -Austria I2H G20 at 20 mbar I3B/P G30/G31 at 50 mbar BE -Belgium I2E+ G20/G25 at 20/25 mbar...
  • Page 21: Technical Data

    Installer information TECHNICAL DATA PIN: 2575DO34681 Natural Gas Category I2E+ I2L/I2EK I2ELL G20/G25 G20/G25 Supply Pressure (mbar) 20/25 Pilot Burner SIT 9043 Nominal Input (Gross kW) 13.5 13.5 13.5/12.2 12.2 13.5/10.9 Gas Rate (Max. m3/hr) 1.26 1.26 1.26/1.35 1.35 1.26 Burner Pressure (Hot mbar) 16.5 16.5...
  • Page 22: Technical Details

    Installer information TECHNICAL DETAILS Ø 650 600 x 600 Ø316/322 Ø213/219 Ø213/219 Ø 950 100°...
  • Page 23: Operating Instructions

    User instructions Version logiciel TYPE DE BATTERIE Presser simultanément les boutons . La version Logiciel s’affiche. Numéro de modèle télécommande Récepteur : 4 x 1,5V “AA”, taille R6. Presser simultanément les boutons . Le modèle télécommande Télécommande : 2 x 1,5V “AAA” (Alcaline uniquement). s’affiche.
  • Page 24 User instructions Figure 01: 8-symbol Display C. . SETTING FAHRENHEIT OR CELSIUS E. CHILD PROOF To change between °C and °F, press buttons simultaneously. To activate press buttons simultaneously. displayed NOTE: Choosing °F results in a 12 hour clock. handset is rendered inoperable, except for the Choosing °C results in a 24 hour clock.
  • Page 25: To Turn Off Fire

    User instructions Handset One-Button Operation TO TURN OFF FIRE (Default Setting) · · Press fbutton until two short beeps and Handset a blinking series of lines confirms the start · Press button to turn OFF. sequence has begun; release button. ·...
  • Page 26 User instructions H. COUNTDOWN TIMER J. THERMOSTATIC MODE ON/SETTING: 1.Press and hold button until displayed, Press button. displayed, preset and hour flashes. temperature displayed briefly, and then room 2.To select hour press button. temperature displayed. 3.To confirm press button. Minutes flash. 4.To select minutes press button.
  • Page 27 User instructions Default settings: NOTE: Either continue to PROGRAM 2 and set on and off times or stop programming at this point, and PROGRAM 2 remains deactivated. ON TIME (Thermostatic) TEMPERATURE: 21 °C (70 °F) OFF TIME TEMPERATURE: “ ” (pilot flame only) NOTE: PROGRAM 1 and 2 use the same on (Thermostatic) and off temperatures for and Daily Timer (, , , , , , ).
  • Page 28: Manual Turn Off

    User instructions MANUAL TURN OFF CLEANING AND MAINTENANCE When the appliance needs to be switched off manually, for example if the This appliance should be inspected and serviced once a year by a qualified, remote control has been lost or the batteries are flat, close the gas shut-off competent and registered person.
  • Page 29: Appendix

    Appendix EXODRAFT EXTRACTOR OPTION B. SUPPLIES Extractor A. GENERAL INFORMATION The exodraft extractors we recommend are specially designed WARNING to work with open gas fireplaces such as the Gyrofocus gas. They are fitted with a pressure sensor to ensure that no smoke is discharged into the home.
  • Page 30 Appendix C. MATERIALS REQUIRED (NOT SUPPLIED) EFC21 controller The EFC21 controller is the system element that controls the : Cable 6x1.5° extractor, solenoid valve and motorized dampers. : Cable 3x1.5° Supply to : Cable 3x1.5° : Cable 2x1.5° High-temperature silicone cable (Customized cable length to PCB output) HT silicone cable is supplied to extend the relay cable to the board output.
  • Page 31 Appendix D. SCHÉMA D'INSTALLATION ~ 220V conduit gaz Gas pipe...
  • Page 32 Appendix E. WIRING DIAGRAM EXTRACTOR WITH PRESSURE SENSOR Extracteur avec capteur de pression L Nreg GNYE ON/ OFF ON/OFF switch ISOLATION SWITCH GAS SOLENOID VALVE (SMG) SMG valve GNYE EFC21 EFC21 SUPPLY Alimentation 3x1,5° (non Fourni) (NOT SUPPLIED) 2x0,75° (non Fourni) (NOT SUPPLIED) START RELEASE...
  • Page 33 Appendix F. EXTRACTOR CONNECTION Install the extractor and its plate on the flue pipe. For mounting the extractor plate, please refer to the extractor documentation. G. SWITCH INSTALLATION Install the switch close to the extractor using the four self-drilling screws supplied. Pay attention to cable length ! Wire the switch according to the electrical diagram below.
  • Page 34: Gas Supply

    Appendix L Nreg GNYE L Nreg EXTRACTOR Cable (supplied) GNYE Cable (not supplied) EFC21 SMG valve H. SOLENOID VALVE INSTALLATION Install the solenoid valve on the gas supply line between the gas supply shut-off valve and the firebox control board. Wire the solenoid valve (photo below) according to the wiring GNYE TO FIREPLACE...
  • Page 35 Appendix SMG valve GNYE I. EFC21 INSTALLATION Install the EFC21 box in an accessible area. Connect the EFC21 (photo below) following the steps below. SOLENOID VALVE SWITCH (not supplied) (not supplied) EFC21 Alimentation SUPPLY (not supplied) Câble 3x1,5° (non Fourni) START RELEASE INLET...
  • Page 36 Appendix K. EXODRAFT EXTRACTOR ADJUSTMENT Start by closing the room's doors and windows to get into normal operating condition. 1- Set extractor pressure switch to minimum (20Pa) 2- Activate service mode on the EFC21 (Press button I -> LEDs A and B flashing). 3- Set extractor speed to maximum (turn the potentiometer K clockwise) 4- Reduce extractor speed until the red light turns green.
  • Page 37: Mertik Fault Finding Chart

    Appendix MERTIK FAULT FINDING CHART FUNCTION POSSIBLE CAUSE REMEDY Replace transmitter batteries. Transmitter batteries low. HANDSET START: 9V quality alkaline recommended. Press both buttons Replace receiver batteries with 1.5V “AA” quality to start ignition (IGN) Receiver batteries low. alkaline batteries. sequence.
  • Page 38 Appendix FUNCTION POSSIBLE CAUSE REMEDY Check connection between cable & Ignition components not operating properly. IGNelectrode. See wiring diagram, p. 33. Check IGN-electrode spark gap. See wiring diagram, p. 33. Check IGN-electrode. See wiring diagram, p. 33. Check IGN-cable for damage. See wiring diagram, p.
  • Page 39: Wiring Diagram

    Appendix FUNCTION POSSIBLE CAUSE REMEDY Check connection of cable to receiver and Pilot lit. TC- and SW-cable reversed. interrupter. See figure 1. Magnet unit not operating properly. Replace gas valve or (magnet unit). Short between interrupter and SW-cable. Check connection to interrupter. No gas (magnet unit drops after 30 second Check gas supply.
  • Page 40 Appendix FUNCTION POSSIBLE CAUSE REMEDY Turn manual knob to “ON” position (positive latch Main burner is lit. Manual knob in “MAN” position. is required). See “Combination control” p. 42. Too much draft at pilot (poor flame Main burner stays lit. Check installation.
  • Page 41 Appendix...
  • Page 42: Combination Control

    Appendix COMBINATION CONTROL The picture below shows the front of the combination control. The combination control is located under the burner base (see page 14). MANUAL knob In MAN Position MANUAL pilot Valve Operator 8 Wire Receiver Jack Microswitch Main Valve knob In OFF Position...
  • Page 43: Declaration Of Conformity

    3 Impasse Claque Patin F - 34380 Viols le Fort declares that the FOCUS decorative, fuel effect gas appliance Ergofocus Gas described here is in accordance with the appliance described in the EC-Type Examination Certificate No. ITS-2575-GAR-2334681 delivered by INTERTEK and comply with the essential requirements applicable to EN 509 :1999 + A1 :2003 + A2 :2004 and Regulation UE 2016/426.
  • Page 44 Note...
  • Page 45 Note...
  • Page 46 Note...
  • Page 47 Note...
  • Page 48 CREATE BEYOND CONVENTION Création - Édition - Distribution : Atelier dominique imbert S.A.S. au capital de 102 355 euros 34380 Viols-le-Fort France Tel. : 00 33 (0)4 67 55 01 93 Web : www.focus-creation.com Email : info@focus-creation.com V.1 - October 2023...

Table of Contents