Hypontech HPS-3000DL User Manual

Single-phase grid-tied solar inverters

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPS-3000DL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hypontech HPS-3000DL

  • Page 2 HPS-3000DL~6000D/ HPS-3000L~6000 Series Single-Phase Grid-tied Solar Inverters USER MANUAL V2.01...
  • Page 3: Table Of Contents

    CATALOGUE SYMBOLS ON THE LABEL .................. 1 SAFETY AND WARNINGS .................. 2 UNPACKING ......................4 3.1 Scope of Delivery ......................4 3.2 Product Overview ......................4 INSTALLING ......................6 4.1 Installation Requirement ....................6 4.2 Mounting Location ......................7 4.3 Mounting ........................... 8 4.4 Installing the PE cable ......................
  • Page 5: Symbols On The Label

    AVOID DAMP AND MOISTURE AVOID CONTACT HIGH TEMPERATURE SHIPMENT STACK LIMIT: 8 AVOID CONTACT DO NOT DISPOSE WITH CE MARKS HOUSEHOLD WASTE PROCEED OPERATIONS AFTER 5 MINUTES BREAKABLE ITEM DISCHARGE PLACE UPWARDS USER MANUAL IN PACK 1 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 6: Safety And Warnings

    2. SAFETY AND WARNINGS All persons who are responsible for mounting, installation, commissioning, maintenance, tests, and service of HYPONTECH inverter products must be suitably trained and qualified for corresponding operations. They MUST be experienced and have knowledge of operation safety and professional methods. All installation personnel must have knowledge of all applicable safety information, standards, directives, and regulations.
  • Page 7 - The transport of the inverter requires two people for lifting, there is one handle on the left and one on the right. - The inverter should be protected from heavy vibrations and shocks during transportation. 3 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 8: Unpacking

    Please inspect and check for completeness in the scope of delivery. Confirm with purchase order. 3.2 Product Overview The total size of HPS-3000DL~6000D/ HPS-3000L~6000 is 395(width) ×328(height) ×154(depth) mm. It has 2 pairs of PV input terminals and 2 communication ports. The detail description is shown below: Mark Num.
  • Page 9 For smart-meter or DRED AC Terminal Connected with AC Grid Secondary PE Terminal For Grounding Protection This series include the models of HPS-3000DL,HPS-3680D, HPS-4000D, HPS-5000D,HPS- 6000D and HPS-3000L,HPS-3680,HPS-4000,HPS-5000,HPS-6000. Please refer to the following table for configuration differences of these models: Model HPS-3000DL,HPS-3680D,...
  • Page 10: Installing

    DO NOT cover the inverter NOR place any objects on top of the inverter. To ensure sufficient room for heat dissipation and maintenance, the clearing space between inverter(s) and other surroundings is indicated below for reference: Avoid direct exposure to sunlight and rain and snow layup. HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 6...
  • Page 11: Mounting Location

    DO NOT mount the inverter on a horizontal surface. For easy installation and operation, please mount the inverter on a height that the display could match eye level. The bottom side where all commissioning terminals are equipped MUST always point downwards. 7 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 12: Mounting

    Check both sides of heat sink and ensure the inverter is stably attached. Use M5 screws (with T25 screwdriver, torque: 2.5Nm) to attach the heat sink fins to the mounting bracket. It is recommended to attach the anti-theft lock to the inverter. Lock diameter φ4- 5.5mm recommended. HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 8...
  • Page 13: Installing The Pe Cable

    Thread the M5 * 13 screw through the terminal lug. Tighten it firmly into the housing (screwdriver type: T25, torque: 2.5Nm). Information on grounding components: Object Description Housing M5 terminal lug with protective conductor M5×13 pan head screw PE Conductor cross-section: 6mm² 9 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 14: Cable Specification

    4.5 Cable Specification HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 10...
  • Page 15: Commissioning

    5.2.2 AC Switch Types Please install an individual 2-stage miniature circuit breaker according to the following specifications. Maximum output current AC Breaker Rated Model (A) current(A) HPS-3000DL/ HPS-3000L HPS-3680D/ HPS-3680 HPS-4000D/ HPS-4000 HPS-5000D/ HPS-5000 HPS-6000D/ HPS-6000 27.3 11 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 16: Dc Wire Assembly And Connection

    This product is equipped with residual current protection device internally, in accordance with IEC 60364-7-712. An external residual current protection device is not needed. If the local regulation demands otherwise, it is recommended to install a 30mA Type B residual current protection device. HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 12...
  • Page 17: Communication

    Datalogger in and tighten. For user guidance and configuration of Datalogger, please refer to the corresponding HYPONTECH Wi-Fi Stick Guide manual, which is available in printed form inside Documents pack, or an online manual on HYPONTECH website at https://www.hypontech.com/xiazai.
  • Page 18 6.1.2 Smart Meter/DRED Connection When installing Meter or DRED, All operation MUST NOT proceed until AC and DC power is securely disconnected and discharged to prevent electric shocks. HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 14...
  • Page 19: Output Power Control Via Smart Meter

    5. Push the seal insert back into the cable gland. Tighten the swivel nut slightly. 6. Place the cover on the housing, then tighten all 4 screws with a Torx screwdriver (screw driver type: T25, torque: 2.2Nm). 15 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 20: Demand Responsive Modes

    Increase power generation (subject to constraints from other active DRM 8 DRMs) The RJ45 socket pin assignments for demand response modes as follows: Pin1-------- DRM 1/5 Pin2------- DRM 2/6 Pin3------- DRM 3/7 Pin4------- DRM 4/8 Pin5------- RefGen Pin6------- Com/DRM0 Pin7--------N/A HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 16...
  • Page 21 5. Press the sealing ring with the network cable into the cable gland, and then tighten the swivel nut firmly. Make sure the cable gland is mounted properly. The cable gland must be adequately locked to prevent any movement of the cable. 6. Secure the cover (screw driver type: T25,torque: 2.5Nm). 17 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 22: Start Up And Operation

    10. Grounding Resistance: Check if the grounding resistance of PV strings >1MOhm using a multi-meter. After all installation and checks, close the AC circuit-breaker, then the DC switch. The inverter will start to operate when DC input voltage and grid conditions meet the requirements of inverter startup. HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 18...
  • Page 23: Inverter Led Indicators

    7.2 Inverter LED Indicators When the inverter operates, LED symbols on display have the following meanings: 19 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 24: Display And Control Logics

    2S but these improvements would not violate short press long press 2S Set Modbus Addr Modbus Addr: standard requirements. Pac=xxxxxW long press 2S short press Ver:V1.0.0.00 Pac=xxxxxW short press Serial Number Pac=xxxxxW short press HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 20...
  • Page 25: Disconnecting From Voltage Sources

    Danger to life due to high voltages. Inverter capacitors need 5 minutes to be completely de-energized. When an error occurs, DO NOT remove the cover of the inverter onsite. Improper operations and attempts may induce electric shock. 21 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 26: Technical Parameters

    5000 6000 (VA) Rated grid voltage(Vac) 220/230/240 Rated power frequency(HZ) 50/60 Rated/Max. output current 27.3 (A) Rated/Max. output overcurrent protection(A) Inrush current (Peak and 15A@ 15A@ 15A@ 15A@ 15A@ duration)* 0.13ms 0.13ms 0.13ms 0.13ms 0.13ms HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 22...
  • Page 27 Output Over Voltage Protection Integrated GENERAL DATA Dimensions(W*H*D) mm 395*328*154 Weight(kg) Noise emission(typical) dB(A) <20 User Interface LCD&LED or LED DC connection type MC4(SNCLIX,H4,D4 optional) AC connection type Plug-in Connector Communication RS485/WiFi/GPRS(optional) Cooling method Natural Cooling 23 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 28 Note The power quality modes can be enabled or disabled via our monitoring APP or Web. Please refer to the “Safety Parameter Setting User Manual” on our website at https://www.hypontech.com/xiazai, or contact our servicer for more information. Only an authorized person can modify the power quality response mode.
  • Page 29: Trouble Shooting

    If an external indication of earth fault alarm is required, please connect PV System to inverter monitoring app/portal. The monitoring platform will send email notification in the event of an Earth Fault. Please refer to Sector 6.1 and HYPONTECH WI-FI STICK GUIDE on how to setup your inverter communication function.
  • Page 30 ⒉ Whether the installation site is in direct sunlight and ambient high higher than 85 degree temperature around the inverter is too high. If all above is normal, contact the service. HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 26...
  • Page 31 2. In case of frequent occurrence but automatic recovery, please confirm if the grid voltage is outside the permissible range due to local grid conditions, try to modify the values of the monitored 27 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 32 Check the connection of DRM device. If the DRM device is DRM S9 Error DRM switch S9 fault connected normally while this fault occurs, please contact the service. HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 28...
  • Page 33 Check the connection of DRM device. If the DRM device is DRM S0 Error DRM switch S0 fault connected normally while this fault occurs, please contact the service. 29 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 34: System Maintenance

    •Check if the cable insulations are damaged, commissioning especially the parts in contact with metal surfaces Annually OR Half a year Half a year after first Grounding • Check if the cables are securely grounded commissioning Annually OR Half a year HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 30...
  • Page 35: Restarts

    Section 6 when applicable (e.g. DC Wires need to be reassembled). Please run safety checks as described in Section 7 before closing the DC Switch and starting up again. 31 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...
  • Page 36: Appendix

    Suitability for isolation Isolating Isolating device device Rated operational current Utilization category/PV utilization category DC-PV2 DC-PV2 Rated short-time withstand current (Icw) 700A 1500A Rated short-circuit making capacity (Icm) 1400A 2000A Rated breaking capacity Ic/Ie: 4 Ic/Ie: 4 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL 32...
  • Page 37 This product is not to be used in multiple inverter combinations and The combination is not tested. If used in multiple inverter combinations, an external devices should be used in accordance with the requirements of AS/NZS 4777.1. 33 HPS-3000DL~6000D/ HPS-3000L~6000 USER MANUAL...