Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Scope of validity These operating instructions apply to the following SIMATIC IPC Hygienic devices which are based on the corresponding standard devices: • SIMATIC IPC PX-39A Hygienic 15" • SIMATIC IPC PX-39A Hygienic 19" • SIMATIC IPC PX-39A Hygienic 22"...
Page 4
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens' products and solutions only form one element of such a concept. Siemens' products and solutions constitute one element of such a concept.
Mounting the device with clamping frame and mounting clips ........... 38 3.2.5 Installing the securing elements ..................39 Connecting the device ....................... 40 3.3.1 Country-specific information on supply voltage ..............40 3.3.2 Connecting the protective conductor ................. 40 SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 6
Technical specifications AC power supply (AC) ..............68 6.5.3 Technical specifications DC power supply (DC) ..............68 Ambient conditions ......................69 Information on insulation tests, protection class and degree of protection ......70 SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 7
Markings and symbols ......................... 81 Overview ........................... 81 Safety ..........................81 Operator controls ......................82 Certificates, approvals and markings .................. 83 Interfaces .......................... 84 List of abbreviations ..........................85 Abbreviations ........................85 Index ..............................87 SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Boot modes Windows® operating Information on: • Online at: system • Commissioning the operating Microsoft® Windows® 10 system (https://support.industry.siemens. • Restoring the operating system com/cs/ww/en/view/109749498) • Configuration of the operating system SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 10
Online at: bootable USB flash SIMATIC IPC Creating a bootable • Creating a bootable USB flash drive USB flash drive drive for recovery of operating (https://support.industry.siemens. system, software and drivers com/cs/ww/en/view/109811224) SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Product description 1.2 Product highlights Product highlights The SIMATIC IPC PX-39A hygienic devices offer a robust front for use in the food and beverage industry as well as in the pharmaceutical industry. Features • Display sizes 15", 19" or 22"...
Display with capacitive multi-touch screen and anti-shatter film ② Mounting gasket ③ Clamping frame ④ Mounting clips in the recesses provided ⑤ Basic strain relief plate ⑥ Additional connector brackets for use in hazardous areas SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
24 V DC power supply ② Slot for memory module ③ Motherboard ④ Backup battery ⑤ Slots for M.2 expansion modules (under removable drives) ⑥ Slot for removable drives (SSD) ⑦ Heat conduction pad SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Accessories and spare parts 1.5.1 Hardware accessories Accessories from Siemens are available for your device that are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall 1. On the Internet, go to Industry Mall (https://mall.industry.siemens.com).
• For control cabinet mounting: Use a central, easily accessible AC circuit breaker close to the device, if possible. • When you install the device, make sure that the power supply connector is easily accessible. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 18
The device is tested and certified on the basis of the technical standards. In rare cases, functional restrictions can occur during plant operation. Validate the correct functioning of the plant to avoid functional restrictions. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
The device contains electronic components which may be destroyed by electrostatic charge. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
DIN/VDE requirements or the applicable country-specific regulations. • Always maintain a minimum clearance of 50 mm to the area of the ventilation slots and do not cover the ventilation slots of the enclosure. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Ne pas déconnecter pendant que le circuit est sous tension, sauf si la zone est non- dangereuse. Le remplacement de composants peut compromettre leur capacité à satisfaire à la Classe I, Division 2 ou Zone 2. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 23
• Immediately shut down the affected machine and label it accordingly. • Handle any potentially contaminated product in accordance with legal regulations. • Replace the device immediately. • Clean the machine before re-commissioning it. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• Always connect the device to a protective conductor. • Additional information on connecting the protective conductor can be found in the section "Connecting the device (Page 40)." SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 25
Do not touch the screen in the following situations: • During the boot process • When plugging or unplugging USB components • While Scandisk is running • During a BIOS update SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
– Electromagnetic interference is present that exceeds the specification according to EN 61000-4-2. – As soon as the malfunction has been remedied, the multi-touch screen is unlocked. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 28
Safety instructions 2.9 Notes on device and system extensions SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Additional connector brackets for use in hazardous areas (option): ② for power supply and USB connection ③ for external interface of M.2 expansion modules ④ for DisplayPort DPP and Ethernet RJ45 connection Mounting gasket SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
If the contents of the package are incomplete, damaged or do not correspond to your order, you can use the After Sales Information System (ASIS) (http://siemens.com/asis) to provide feedback on product deliveries and repairs. Complete the online form for product delivery (quality control notification) under the heading "Product delivery: Feedback on quality control and repairs".
The COA label (Certificate of Authenticity) is located on the side of the device. Note The COA label is only available on devices shipped with an installed Microsoft® Windows® operating system. Example of COA label for the Microsoft® Windows® 10 operating system: SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
"Ambient conditions (Page 69)". Mounting in horizontal format Vertical mounting in horizontal format or inclined mounting in horizontal format with vertical inclination of max. ±45°: For temperature specifications, see section "Ambient conditions (Page 69)". SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Only then can antimicrobial cleaning of the device and its environment be guaranteed. • The installation area is dry and free from contamination, such as dust or lubricant. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Improper actions during installation and assembly may lead to personal injury and/or substantial damage to equipment. You should observe the installation and assembly notes under: • Notes on mounting (Page 21) • Notes on ambient and environmental conditions (Page 21) SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
You fasten the devices with the mounting clips from the accessory kit. For all hygienic devices, there are two cutouts for a mounting clip in the frame at all required positions. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 36
To achieve degree of protection IP69 for the respective device, the mounting clips must be fitted at the positions shown below. Device Positions of the mounting clips 15" Hygienic 19" Hygienic 22" Hygienic SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
– The mounting gasket lies fully flat against the back of the stainless steel frame. – The edge of the mounting gasket is flush with the edge of the stainless steel frame all around. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Secure the device against dropping during the entire installation. If necessary, work in pairs when installing the device. 1. Insert the device with inserted mounting gasket into the mounting cutout. 2. Place the clamping frame on the rear of the device. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
4 screws ⑤ from the accessory kit. 6. Screw the connector bracket ⑥ to the underside of the device with the 2 screws from the accessory kit (see red markings). SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
I/O devices to ground. The connection for the protective conductor is labeled with the following symbol: SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 41
2. Screw the cable lug onto the protective conductor connection as shown. 3. Wire the protective conductor to the protective conductor connection of the control cabinet in which the device is installed. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• Operation in non-grounded or impedance-grounded networks is not permitted. Note The varying voltage power supply module is designed for operation on 120/230/240 V AC networks. The setting of the voltage range takes place automatically. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 43
2. Insert the capacitor IEC plug at the marked position. 3. Connect the power cable with the safety power outlet. 4. If necessary, install the enclosed cable grip. See also Connecting the protective conductor (Page 40) SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Make sure that the cores are connected to the correct terminals. Observe the labeling for the contacts on the device. 1. Connect the cables as shown with a tightening torque of 2.5 Nm. Make sure the connection terminal is in the correct position as shown. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
The 24 V DC power supply is protected against polarity reversal. If you mix up the 24 V DC connecting cables and ground, the device is not damaged but does not switch on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• Cable ties (not included in the scope of delivery) Procedure 1. Pass the cable tie around the strain relief bar and secure the cables as shown. 2. Cut off the protruding ends of the cable ties. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
The following figure shows an example of how to secure connectors in a captive manner. To do this, attach the cable plugs (green, black) to the openings of the connector brackets using cable ties (white): SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 48
Installing and connecting the device 3.3 Connecting the device SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Switching off the device Shutting down the operating system For active operating system • Shut down the operating system properly. Result The device is switched off but not fully disconnected from the line voltage. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• Press the on/off switch to trigger a hardware reset, see "Interfaces and operator controls with 24 V DC power supply (Page 13)" or "Interfaces and operator controls with 100-240 V AC power supply (Page 14)". See also General safety instructions (Page 17) SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
As soon as the Smart status of the data storage medium goes to "Not OK", a message is generated in SIMATIC IPC DiagBase or SIMATIC IPC DiagMonitor or also during a system start of the device. You should then back up your data and replace the drive. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
This can trigger an explosion resulting in injuries and machine damage. • Do not use a dry cloth to clean the front panel. • Use a well moistened cloth or a suitable anti-static cleaning device. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 53
Prevent unintended reactions during cleaning If you clean the front panel while it is switched on, you can trigger inadvertent operations on the touch screen. Switch off the HMI device during cleaning. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• Remove visible buildup immediately. • Avoid direct contact of foodstuff with the anti-shatter film. • Prevent foodstuff removed from the device from getting back into the production process. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• If necessary, use a flat jet nozzle and keep a distance of at least 50 cm. NOTICE Observe the ambient conditions During cleaning work, adhere to the permissible ambient conditions, especially the operating temperature, see section "Ambient conditions (Page 69)". SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
– Remove new rust spots with a mild abrasive detergent in order to prevent any further corrosion. – Rinse thoroughly with clean water after each cleaning. • Ensure that the cleaning agent is completely removed without any residue. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• Cover the device during cleaning of the plant. • Clean the device separately using a suitable procedure. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 58
If the stainless steel parts are unintentionally contaminated with hydrochloric acid, rinse these off immediately with plenty of water. • Clean the stainless steel surface with a cleansing agent without active chlorine. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
2. Place the new battery below the two contacts (1) and press it into the base (2) while applying slight pressure. 3. Close the device. 4. Check the firmware/BIOS settings. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old device, and dispose of it according to the relevant regulations in your country. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• 2014/35/EU "Electrical equipment designed for use within certain voltage limits" (Low- Voltage Directive) Conformance with this standard has been verified according to IEC/EN 61010-2-201 • 2011/65/EU "Restriction of the use of certain hazardous substances in electrical and electronic equipment" (RoHS Directive) SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
DIN ISO 9001 certificate and software license agreements ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
6.2.6 Canada CANADA Canadian Notice This Class A digital apparatus complies with Canadian ICES-003. Avis Canadien Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
6.2.9 Fraunhofer Fraunhofer TESTED DEVICE® Siemens AG, SIMATIC Hygienic Panel Front Report No. SI 2301-1378, valid until 8 March 2028 At the Fraunhofer Institute, the purity and cleanroom suitability test was carried out and passed in accordance with the GMP standard (EU GMP Annex 1; EHEDG Doc. 8; DIN EN 1672- 2;...
The device may only be connected to a 24 V DC power supply which meets the requirements of a safe extra-low voltage (SELV/PELV) in accordance with the standard IEC/UL/EN/DIN EN 61010-2-201. not evaluated by UL SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
12 W NVMe SSDs in the SIMATIC IPC Slider - 0.25 A 5.9 W additional M.2 slots - additional 0.25 A 5.9 W PCIe slot - additional 0.38 A 9.2 W SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Max. 8 A for further 40 ms Max. 4.1 A²s • I²t value: Active power 94 W Output data Voltages +12 V / 6.7 A Secondary power output Max. 80 W SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Temperature 30 °C, relative humidity 85%; Permitted range: 0 to 31 °C: 5 ... 80%; decreasing linearly to 5 ... 25% at 55 °C - Storage/transport Temperature 25 °C - 55 °C, relative humidity 95% SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
"Preparing the mounting cutout (Page 33)". • The device has been installed according to the information provided in this document. Note The IP degrees of protection were not tested by UL. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com) • Support request form (https://www.siemens.com/supportrequest) • After-sales information system for SIMATIC PC / PG (https://www.siemens.com/asis) • SIMATIC Documentation Collection (https://www.siemens.com/simatic-tech-doku-portal) • Your local representative (https://www.automation.siemens.com/aspa_app) • Training center (https://siemens.com/sitrain) •...
1. Call the firmware/BIOS configuration menu. To do this, press the "<Esc>" button during the boot process and then select "Setup Utility". 2. Set the date and time in the "Main" tab and save the changes. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
• Signal frequencies or signal expansion card was the cause of the fault. Replace this with a levels are not adhered to Siemens expansion card or contact the supplier of the • Different pin assignment expansion card. If the device still crashes, contact your technical support team.
Warning, observe the supplied Lock is closed documentation. Attention, radio equipment Lock is open Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Markings and symbols B.3 Operator controls Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical On/off switch, without electrical isolation isolation SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters UKCA marking for Great Britain Laboratories Approval for India Disposal information, observe the local regulations. Approval for Taiwan SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
LAN interface, not approved for Line Out connecting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Extensible Firmware Interface Electrostatic-sensitive components European standard Ground Chassis ground Hard Disk Drive Hard disk drive Height unit Input/Output Data input/output on computers iAMT Intel® Active Management Technology International Electronical Commission SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 86
(with CSA / Canada) standards. Universal Serial Bus Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Page 88
Steam cleaners, 55 Strain relief, 39, 46 Supply voltage For countries other than the USA and Canada, 40 USA and Canada, 40 Taiwan, 65 Temperature, 69 Touch screen Operation, 26 Weight, 66 SIMATIC IPC PX-39A Hygienic Compact Operating Instructions, 03/2025, A5E54273722-AA...
Need help?
Do you have a question about the SIMATIC IPC PX-39A Hygienic and is the answer not in the manual?