Installation Instructions RMGZ9-Series 1 Table of contents TABLE OF CONTENTS ..........................2 SAFETY INSTRUCTIONS .......................... 3 Presentation of safety information ..................... 3 2.1.1 Danger that could result in minor or moderate injuries ..............3 2.1.2 Note regarding proper function ...................... 3 General safety information .........................
Installation Instructions RMGZ9-Series 2 Safety instructions All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to the equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Installation Instructions RMGZ9-Series 3 Product information 3.1 Product description The force measuring rollers of the RMGZ9-Series combine force sensor and roller. The RMGZ9-Series design, incorporating dual bending beams, eliminates the load-specific influences of torque and ensures accurate measurement at any position on the roller while maintaining the parallel position of the material and eliminating angular deflection.
Installation Instructions RMGZ9-Series 3.4 Order code Figure 2: order code Datasheet_RMGZ9_series.indd 3.5 Scope of delivery Included in scope of delivery Force sensor, straight connector (female) Options small connector, round type C 091 Axial electrical connection, repaces radial, small connector, round type C 091 right-angle connector in scope of supply, replaces straight connector temperature range up to 120°C (248°F) with water tight, straight connector, replaces original conector...
Installation Instructions RMGZ9-Series 4 Installation 4.1 Installation conditions The Force Measuring Roller are defined as “partly completed machinery” according to the Directives 2006/42/EC, article 2. In order to assure a proper functionality of the parts and assure the essential safety requirements of operators working with it, the following conditions for the assembly must be met: The Force Measuring Rollers may not be stressed over the specification limits neither during assembly nor operation.
Installation Instructions RMGZ9-Series 4.4 Electrical connections Connection between force sensor and measuring amplifier is realized by means of a 2 x 2 x 0.25mm shielded, twisted-pair cable. The cable must be installed separate from power lines. Connect the shielding only on the side of the measuring amplifier. Figure 6: pin assignment M14 x 1, 5-pole Pin_Assignment_Sensorkabel_Farben_Stecker.ai 30.06.2023...
Installation Instructions RMGZ9-Series 5 Maintenance The included bearings are lifetime lubricated. The force sensor is maintenance-free. If any maintenance should be necessary, we recommend contacting FMS customer service and to send the unit FMS for maintenance. WARNING The measuring body and the roll are delicate parts and may be damaged by improper handling! Maintenance must be carried out by trained service personal only.
Need help?
Do you have a question about the RMGZ9 Series and is the answer not in the manual?