FMS RTM X42.Modbus Installation Manual And Operating Instructions

Telemetry system for wire tension measurements in cage and tubular type stranders

Advertisement

Quick Links

RTM X42.Modbus Installation Manual and
Operating Instructions
Telemetry System for Wire Tension Measurements in Cage
and Tubular Type Stranders
Document version
3.20
Published/author
12/2019 NS
Diese Bedienungsanleitung ist auch in Englisch erhältlich.
Bitte kontaktieren Sie Ihren nächstgelegenen FMS Vertreter.
© by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTM X42.Modbus and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FMS RTM X42.Modbus

  • Page 1 Telemetry System for Wire Tension Measurements in Cage and Tubular Type Stranders Document version 3.20 Published/author 12/2019 NS Diese Bedienungsanleitung ist auch in Englisch erhältlich. Bitte kontaktieren Sie Ihren nächstgelegenen FMS Vertreter. © by FMS Force Measuring Systems AG, CH-8154 Oberglatt – All rights reserved.
  • Page 2: Table Of Contents

    RTM X42.Modbus Installation Manual and Operating Instructions 1 Content CONTENT ..............................2 SAFETY INFORMATION ........................... 3 Presentation of Safety Information ..................... 3 2.1.1 Danger that Could Result in Minor or Moderate Injuries ............... 3 2.1.2 Note Regarding Proper Function ....................3 General Safety Information ........................
  • Page 3: Safety Information

    Secure the battery using the knurled screws Changes or modification to this device that have not been expressly approved by FMS AG, will result in the FCC approval for operation of this device being voided. This device complies with the FCC Rules Part 15 as well as the RSS standards issued in Canada not requiring approval.
  • Page 4 RTM X42.Modbus Installation Manual and Operating Instructions subject to the following two conditions: The device may not cause any harmful interference, and This device must accept any interference received, including interference that may cause undesired operation of the device Information about radio frequency radiation This device complies with the FCC limit values for an uncontrolled environment.
  • Page 5: Product Information

    RTM X42.Modbus Installation Manual and Operating Instructions 3 Product Information 3.1 Functional Description The telemetry system RTM X42 uses force sensors for measuring the wire tension of strands and wires. It radio-transmits the measured values from the rotating to the static part of the machine.
  • Page 6: Main Components

    RTM X42.Modbus Installation Manual and Operating Instructions 3.3 Main Components Figure 1: RTM X42 main components RTM_X42_Modbus_BA_Manual.ai Main component designations Item Description 1a to 1f Telemetry system RTM X42 Force sensor(s), according to your specifications Channel extension module(s) Transmitter module...
  • Page 7: Scope Of Supply

    RTM X42.Modbus Installation Manual and Operating Instructions 3.4 Scope of Supply Scope of supply: Force sensors, model and size according to specification; transmitter module(s) with battery/ies and charger, channel extension module(s); receiver module(s); pre- fabricated connection cables, force sensor to channel extension module and/or to receiver module;...
  • Page 8: Installation And Electrical Connections

    Non-compensated force-measuring rollers lead to faulty measurements, In the case of FMS force sensors of the RMGZ series, this is achieved by aligning the force sensor such that the measuring direction is exactly parallel to the axis of rotation of the strander.
  • Page 9: Installation Of The Electronics Components In The Rotating Part Of The Machine

    Otherwise, measured value fluctuations occur during machine operation due to the high sensitivity of the FMS force sensors. These interfere with the assessment of the product quality later. Due to irregularities in the installation surfaces, the alignment may have to be readjusted very precisely.
  • Page 10: Electrical Connection

    RTM X42.Modbus Installation Manual and Operating Instructions Abbildung 4: Installation RTM_X42_Modbus_BA_Manual.ai 4.4 Electrical Connection 4.4.1 EMGZ482T.Modbus Receiver Module (with battery) The connection cables are pre-fabricated with respective connectors. 09.12.2019...
  • Page 11: Emgz482T.modbus.24Vdc Receiver Module (Version Without Battery, With 24Vdc Power Supply Via Slip Rings On The Strander)

    RTM X42.Modbus Installation Manual and Operating Instructions Figure 5: EMGZ482T.Modbus electrical connection RTM_X42_Modbus_BA_Manual.ai 4.4.1 EMGZ482T.Modbus.24VDC Receiver Module (version without battery, with 24VDC power supply via slip rings on the strander) The connections between the force measuring rollers and transmitter are realized using a 2x2x0.25 mm2 [AWG 23] cable with 2 shielded, twisted pairs of strands.
  • Page 12 RTM X42.Modbus Installation Manual and Operating Instructions Figure 6: EMGZ482T.Modbus.24VDC electrical connection RTM_X42_Modbus_BA_Manual.ai 09.12.2019...
  • Page 13: Emgz484T.modbus Channel Extension Module

    RTM X42.Modbus Installation Manual and Operating Instructions 4.5 EMGZ484T.Modbus Channel Extension Module Figure 7: EMGZ484T.Modbus electrical connection RTM_X42_Modbus_BA_Manual.ai Bus Termination Plug All Bus & Power Socket have to be connected. Otherwise errors in communcaiton may occure. Always insert the included bus termination plug to last channel extension module in the row (out).
  • Page 14 RTM X42.Modbus Installation Manual and Operating Instructions Figure 8: EMGZ482R.Modbus electrical connection RTM_X42_Modbus_BA_Manual.ai EMGZ482R.Modbus pin assignment Pin(s) Description 24 VDC+ 24 VDC- 10, 11 24 VDC output GND for 24 VDC Digital input for production length Analog input for force sensor core 16, 26 Relay 1/1 –...
  • Page 15: Operation And Display

    RTM X42.Modbus Installation Manual and Operating Instructions 5 Operation and Display The EMGZ482R.Modbus receiver module features buttons and a display for the configuration. The >0< and Cal buttons have no function. System parameters can be adjusted via the operating panel Figure 9: Receiver module operation and display RTM_X42_Modbus_BA_Manual.ai...
  • Page 16: Offset Compensation Of The Force Sensors

    RTM X42.Modbus Installation Manual and Operating Instructions 5.1 Offset Compensation of the Force Sensors Offset compensation is used to compensate for the weight of the pulley on the force sensor. The measuring system is practically “zeroed.” Observe the following: The force sensor may only be loaded with the pulley (do not place a wire) Turn the lay-plate until the force sensor, for which the offset compensation is performed, is vertically over the axis of rotation (12 o’clock position)
  • Page 17: Charger

    RTM X42.Modbus Installation Manual and Operating Instructions Figure 11: Application of a defined weight force to the force sensor RTM_X42_Modbus_BA_Manual.ai To adjust the gain, load the measuring roller with a cable with a defined weight attached to its end. The cable must correspond to the real material course in the machine (wrap angle, distances between the rollers, etc.).
  • Page 18: Configuration

    RTM X42.Modbus Installation Manual and Operating Instructions 6 Configuration 6.1 Quick Start Insert the battery into the EMGZ482T.Modbus transmitter module and secure with both knurled screws. The screws must be tightened sufficiently otherwise, the centrifugal forces caused by cage rotation could eject the battery.
  • Page 19: System Parameters

    RTM X42.Modbus Installation Manual and Operating Instructions 6.2 System Parameters The system parameter group contains the general parameters that control the operation of the RTM X42 system, but do not influence the actual measurement. Figure 13: System parameter 1 RTM_X42_Modbus_BA_Manual.ai...
  • Page 20 RTM X42.Modbus Installation Manual and Operating Instructions Figure 14: System parameter 2 RTM_X42_Modbus_BA_Manual.ai 09.12.2019...
  • Page 21: System Parameter Overview

    RTM X42.Modbus Installation Manual and Operating Instructions 6.3 System Parameter Overview System Parameters Parameter Description Language Language on the display of the operating panel Unit [-] Values German, English, Russian Default English Inv.Sign Inverts the signal of all force sensors...
  • Page 22 RTM X42.Modbus Installation Manual and Operating Instructions Default LANSpeed Data rate of LAN connection Unit BPS Default IP Addr. IP address (static) of the EMGZ482R.Modbus receiver module. Address is entered in 4 blocks. Unit [-] Default 192.168.000.090 Subnet Address of subnet mask. Is entered in 4 blocks...
  • Page 23: Gateway

    RTM X42.Modbus Installation Manual and Operating Instructions 7 Gateway A gateway from Anybus is available as accessory item from FMS. In the following, the configuration of a Modbus TCP – Profibus DP gateway is explained as example. 7.1 Electrical Connection Figure 15: Gateway electrical connection RTM_X42_Modbus_BA_Manual.ai...
  • Page 24: Summary Of Gateway Installation And Start-Up

    Table 5: Gateway Technical Data 7.4 Data Exchange between RTM and PLC The configuration between the RTM X42 system and the gateway is configured by FMS. The system can be restored using a configuration file as needed. This file is available via the FMS Service department.
  • Page 25 RTM X42.Modbus Installation Manual and Operating Instructions Table 6: Install Anybus IPconfig from CD (provided with the gateway). Table 7: Start Anybus IPconfig program. It is possible to search for the listed gateway again using the Scan button. Double-clicking on the listed line opens the configuration window.
  • Page 26 RTM X42.Modbus Installation Manual and Operating Instructions Figure 16: The website of the RTM X42 gateway can be accessed using a web browser and the following IP address: 192.168.0.100. Figure 17: If a configuration file is available, it can be loaded under “Backup & Restore.”...
  • Page 27 RTM X42.Modbus Installation Manual and Operating Instructions Figure 19: The settings for the Modbus communication from the RTM X42 gateway to the RTM X42 are defined under “Modbus Servers.” To do so, click on the “Add new server” field. Figure 20: A new server connection is inserted. Changes become only effective after a restart.
  • Page 28 RTM X42.Modbus Installation Manual and Operating Instructions Figure 22: Next, click on “Transactions” Figure 23: Insert a new communication transaction using the “Add new transaction” button. Figure 24: Edit this new transaction using “Edit”. 09.12.2019...
  • Page 29 RTM X42.Modbus Installation Manual and Operating Instructions Figure 25: Enter the data respectively and confirm with OK Figure 26: Here, all wire tension data (50 registers) are retrieved with a cycle time of 10ms from the RTM X42 device and transferred to the RTM X42 gateway. The MODBUS register contains the data mapping information.
  • Page 30 RTM X42.Modbus Installation Manual and Operating Instructions Figure 27: The changes must still be saved with “Apply” under “X-gateway Management.” Figure 28: The RTM X42 gateway is restarted after confirming with the OK button 09.12.2019...
  • Page 31: Anybus Gateway Ab9001 Register

    RTM X42.Modbus Installation Manual and Operating Instructions Figure 29: The configuration can be saved in a file under “Backup & Restore” Figure 30: The current data is visible under “Transaction Monitor” 7.5 ANYBUS Gateway AB9001 Register The RTM X42 system provides a bit stream with the raw cable tension data of 42 channels every 10 ms.
  • Page 32 RTM X42.Modbus Installation Manual and Operating Instructions ANYBUS Gateway AB9001 input register Offset Type Length Name Description INT16 Channel 1 Raw date in digits (ADC value) 5898 digits= nominal force INT16 Channel 2 = 5.4mV analog DMS input INT16 Channel 3...
  • Page 33 RTM X42.Modbus Installation Manual and Operating Instructions ANYBUS Gateway AB9001 input register Offset Type Length Name Description INT16 Channel 32 Raw date in digits (ADC value) 5898 digits= nominal force INT16 Channel 33 = 5.4mV analog DMS input INT16 Channel 34...
  • Page 34: Maintenance

    RTM X42.Modbus Installation Manual and Operating Instructions 8 Maintenance The force sensors are maintenance-free. If repairs are necessary, we recommend contacting FMS Customer Service and sending the affected components for revision to FMS. 09.12.2019...
  • Page 35: Dimensions

    RTM X42.Modbus Installation Manual and Operating Instructions 9 Dimensions Figure 31: Dimensions of the EMGZ482R.Modbus receiver module Figure 32: Dimensions of the EMGZ482T.Modbus transmitter module Figure 33: Dimensions of the EMGZ484T.Modbus channel extension module 09.12.2019...
  • Page 36: Error Causes And Troubleshooting

    RTM X42.Modbus Installation Manual and Operating Instructions 10 Error Causes and Troubleshooting Troubleshooting Message Cause Remedy “Radio link lost” Radio connection to the Check battery in the EMGZ482T EMGZ482T is (battery empty or not interrupted. inserted?). Metal objects interfere Remove antennas from the with the transmission interference range.
  • Page 37: Technical Data

    RTM X42.Modbus Installation Manual and Operating Instructions 11 Technical Data 11.1 EMGZ482T.Modbus Transmitter Module EMGZ482T.MODBUS Number of measuring 2 channels for 2 force sensors points Measuring inaccuracy <0.05% F System Sensor excitation 3.0 VDC, max. 20mA, highly stable Power supply 3.7V battery Li Ion (20Ah) or...
  • Page 38: Emgz484T.modbus Channel Extension Module

    RTM X42.Modbus Installation Manual and Operating Instructions EMGZ482R.MODBUS (tachometer impulses for Cycle time: ≥ 10ms, production length) Max. frequency: ≤ 100 Hz Conditions: 5ms on / 5ms off Analog input 0 to 10 VDC; min. 1.2kΩ (for core) Temperature range 0 to 50°C [32 to 122°F]...
  • Page 39: Lloyd's Register Type Approval

    RTM X42.Modbus Installation Manual and Operating Instructions Magnitude of Test Class A digital device, pursuant to Part 15 of the FCC (Coverage) Rules Certification FCC Registration #: 0020311882 RTM X42 CAB Radio Certification for Japan Magnitude of Test Low power data communi. FXD; Art. 38 - 24, Paragraph 1...
  • Page 40 RTM X42.Modbus Installation Manual and Operating Instructions FMS Force Measuring Systems FMS USA, Inc. FMS (UK) FMS (Italy) 2155 Stonington Avenue Suite Aspstrasse 6 Aspstrasse 6 Aspstrasse 6 8154 Oberglatt (Switzerland) 8154 Oberglatt (Switzerland) 8154 Oberglatt (Switzerland) Hoffman Estates,, IL 60169 Tel.