Doc. no. DOC1119048-1 PRODUCT NAME Exhaust Flow Control Valve with Silencer Push-lock Type / Compact Indicator Type MODEL / Series / Product Number ASN2 Series...
Doc. no. DOC1119048-1 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These in- structions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
Doc. no. DOC1119048-1 Safety Instructions Caution SMC develops, designs, and manufactures products to be used for automatic control equipment, and provides them for peaceful use in manufacturing industries. Use in non-manufacturing industries is not allowed. Products SMC manufactures and sells cannot be used for the purpose of transactions or certification specified in the Measurement Act of each country.
Doc. no. DOC1119048-1 2. Precautions Mounting Design/Selection Caution Warning (3)To adjust the speed, start with the knob in the fully-closed position, and then make adjustment by gradually turning it coun- (1) Check the specifications. terclockwise. Products represented in this manual are de- signed only for use in compressed air sys- Depending on the opening adjustment con- tems.
Page 6
Doc. no. DOC1119048-1 Mounting Mounting Caution Caution (7)If installing flow controls to valve ports, Chamfered area for female thread interference may occur with the fittings. In compliance with ISO 16030 (air pressure Please consult the catalog before in- fluid dynamics-connection-ports and stud stalling.
Page 7
Doc. no. DOC1119048-1 Mounting Mounting Caution Caution Winding of sealant tape (12)Lifting force for the knob Leave the beginning of the screw cut and The lifting force for the knob is specified as wrap the sealing tape around it. If the tape is shown in the table below.
Doc. no. DOC1119048-1 (4)Use clean air Piping Do not use compressed air that contains chemicals, synthetic oils that include organic Caution solvents, salt, corrosive gases, etc., as it can (1)Prior to piping cause damage or malfunction. Before piping is connected, it should be thor- Air Supply oughly blown out with air (flushing) or washed to remove chips, cutting oil and...
Page 9
Doc. no. DOC1119048-1 Maintenance Warning (4)Maintenance work If handled improperly, compressed air can be dangerous. Assembly, handling, repair, and element replacement of pneumatic systems should be performed by a knowledgeable and experienced person. (5)Drain flushing Remove drainage from air filters regularly. (6)Removal of equipment, and supply/ex- haust of compressed air.
Doc. no. DOC1119048-1 3. Application This product is intended to be attached to the exhaust port of a directional control valve to control the speed of a pneumatic actuator. 4. Specifications Fluid Pressure renge 0 ~ 1 MPa Proof pressure 1.5 MPa Amblent and fluid temperature -5 ~ 60℃...
Doc. no. DOC1119048-1 6. Construction Seal method/Gasket seal For M5, 10-32UNF Push-lock Type Compact Indicator Type For R, NPT Push-lock Type Compact Indicator Type Description Material Note Handle Needle Needle guide Brass Electroless nickel plating O ring Sponge PVA Sponge Cover Body B Indicator guide...