INSTALLATION AND OPERATION DIRECT-VENT VISION™ P/N 775222M REV. F 09/2011 MODELS Portland OTL Report No. 050-S-16b-5 VISN-25/35 SDVSS-25/35 Ce manuel d’installation est disponible en francais, s implement en faire This Gas Stove is factory equipped for 35,000 BTU input and can be converted to 25,000 using a smaller orifice (provided in optional orifice kit P/N H5966).
LP and Natural Gas Supplies .......18 your new gas stove. Installer - Attaching Safety In Operation Warnings ....19 Operating Instructions ..........20-23 Thank you for selecting a Lennox Hearth Products gas stove as the answer to your home heating needs. Pre-Lighting Checklist ........20 Lighting Instructions ........20-21 TABLE OF CONTENTS Flame Color and Behavior ........21...
IMPORTANT SAFETY AND WARNING AVERTISSEMENT INFORMATION On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à prox- WARNING imité. Young children should be carefully supervised when WARNING they are in the same room as the appliance. Tod- dlers, young children and others may be susceptible Any safety screen or guard removed for servicing to accidental contact burns.
Page 5
T hese appliances are vented gas appliances. Do not burn wood F OR YOUR SAFETY do not install or operate this appliance without or other material in these appliances. first reading and understanding this manual. Any installation or operation of the appliance deviating from that which is stated T his appliance is only for use with the type of gas indicated on in this manual WILL void the warranty and may be hazardous.
3. If you are unable to locate the labels, please call (Figure C). Choisissez la langue qui est principale Lennox Hearth Products o al distribuidor de Lennox Lennox Hearth Products or your nearest Lennox ment parlée dans la résidence du propriétaire.
Changing the orifice should only be done by a qualified service (In Canada, the current CAN/CSA B149.1 installation code). Refer to technician. Contact your Lennox Hearth Products dealer for proper orifice the National Fuel Gas Code and local zoning and code authorities for sizes (see Page 26 for more information).
If there are any questions or if you need further centimeters) in length. substantiation either write to or call your Lennox Hearth Products dealer. If you have further questions, please contact Lennox Hearth Products. • The individual manual shutoff must be a Thandle type valve.
(liquid propane) by changing the cassette (valve and pilot assembly) or Manufactured (mobile) home installing a conversion kit. Only Lennox Hearth Products conversion kits Natural gas (NG) or propane (LP) can be used to convert from NG to LP or LP to NG. Contact your Lennox Bedrooms Hearth Products dealer for details.
Test all gas connections for leaks with a gas leak test solution. The Lennox Hearth Products warranty will be voided if one of the fol lowing occurs: Top View •...
Alcove dimensions Clearances to Combustibles Minimum clearances to combustible materials in inches (millimeters): The minimum width between the alcove side walls is 51” 1295mm). The minimum height of the alcove is 46” (1168mm) and the maximum depth is 35” (889mm). Parallel Installation Alcove Dimensions 2”...
Conversion from Standard 35,000 BTU To Optional 25,000 BTU INSTALLATION Input To convert input from 35,000 BTUs to 25,000 BTU's, remove and replace Installing Door Trim And Spring Handle the stock burner orifice with the #36 NG orifice supplied in the optional orifice kit P/N H5924.
Brick Panel And Log Set Installation 5. Place ember material (rockwool) over ports. The ember material can be placed to obscure air holes, but do not cover the air holes. If logs are not installed according to the log installation instruc- * Fifty percent or less of ember material (rockwool) supplied should tions, flame impingement and improper combustion could be used in LP installations.
9. Set center log on support with charred surface toward you and rest Residential and Mobile Home Installations: against the rear log. These are the minimum pieces required. Other parts may be required for your particular installation. Minimum Components for Horizontal Installation: Horizontal Termination Kit which includes: •...
Vent Parts List Horizontal Vent Installation Secure Vent™ directvent pipe by Security Chimneys™* may be used with Venting terminals may not be recessed into a wall or siding. this appliance. Please see the lists below to verify the components avail able from each directvent pipe manufacturer.
Flue Restrictors The flue restrictor settings shown in Figures 19 and 20 are for typical 14” Snorkel installations and may need to be adjusted from standard to take into account other variables in the installation to achieve proper combus- tion. See Flue Restrictor Guidelines on this page to assist you in making a proper flue restrictor adjustment.
Horizontal Terminations To install the stove with pipe directly out the back, a snorkel is not required for VISN25 / SDVSS25 gas stoves. A snorkel is required for The shaded areas in the diagram below show all allowable combinations the VISN35 / SDVSS35 gas stoves. See Pages 14 and 15 for snorkel of vent configurations with horizontal terminations.
Exterior Horizontal Vent Termination Clearance Requirements * See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal Termination 18” Ventilated Soffit Inside Corner = 9" in U.S. = 12" in Canada DETAIL D 3 ft.
(LP) if a certified fuel (with the appliance burning) insert a small flatbladed screwdriver into conversion kit provided by Lennox Hearth Products is installed by a the tap and turn a halfturn counterclockwise. Cover the tap with the qualified service technician.
3. Si no puede encontrar las etiquetas, sírvase llamar a Lennox Hearth Products or your nearest Lennox taire. En cas de doute, collez l’étiquette en anglais. Lennox Hearth Products o al distribuidor de Lennox Hearth Products dealer to receive additional 3. Si vous ne trouvez pas les étiquettes, veuillez Hearth Products más cercano para recibir etiquetas...
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” on CAUTION: YOUR LENNOX HEARTH PRODUCTS GAS APPLIANCE this page. If you don’t smell gas, go to the next step.
10. After pilot is lit, turn gas control knob counterclockwise Gas Control Knob Igniter to “ON.” Knob can only be turned to “ON” if the knob (pilot/on/off) has popped out. 11. To turn burner on, turn “ON/OFF” rocker switch to “ON” or set the thermostat to the desired temperature above room temperature.
Quiet Operation Proper Pilot Flame Appearance As the appliance is burning, a number of normal operational sounds may be heard. The flow of gas through the gas valve and orifice may make a rushing or whistling noise. If this noise is objectionable, it can be reduced by turning down the flame.
Operating Options Thermostat Wire Wire Size Maximum Length Your stove comes equipped with an “On/Off” rocker switch used to turn the burner on and off while the pilot light is on. The switch is a round 12 Gage 100 Feet rocker switch located behind the main control panel door.
The viewing glass should be cleaned periodically (see Glass Door MAINTENANCE AND SERVICING Cleaning and Maintenance). Should repairs or maintenance of the stove require the disassem- WARNING bly of the vent/air intake system, the reassembly and resealing should be completed by a qualified service technician and follow Turn off gas and electrical power to the fireplace the instructions on Pages 13, 14 and 15 of this manual.
If the glass is broken in the glass door, the entire door (metal frame, gasket and glass) should be replaced as a unit. This replacement glass door is available from your Lennox Hearth Products dealer. Do not CAUTION use substitute parts or materials. The glass is neoceramic and alterna...
Fuel Conversion Converting the stove between natural gas (NG) and propane (LP) can be accomplished by either changing the cassette (valve and pilot assembly) or installing a conversion kit (regulator, burner orifice and repositioning the slide orifice of the pilot). Only a qualified service technician should perform the conversion.
TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
Wire Harness Diagram CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
Contact an Lennox Hearth Products dealer to obtain any of these parts. REPLACEMENT PARTS - VISN-25/35 AND SDVSS-25/35 Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. Cat. No. Description WARNING H3136 Cassette Assembly, NG (if LP, also requires 75265...
Portland MANUFACTURED BY / FABRIQUÉ PAR: MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES. LENNOX HEARTH PRODUCTS PO BOX 987 TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91. Report No. / Número de Rapport AUBURN, WA., USA 98071...
Page 33
LIGHTING LABEL - VISN-25/35 AND SDVSS-25/35 FOR YOUR SAFETY READ BEFORE OPERATING POUR VOTRE SÉCURITÉ, LIRE AVANT L’ALLUMAGE WARNING: AVERTISSEMENT: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING SI VOUS NE RESPECTEZ PAS RIGOUREUSEMENT LES INSTRUCTIONS CI-DESSOUS, VOUS POURRIEZ ENCOURIR UN RISQUE D’INCENDIE ET/OU PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
Fuel Type (Check one) c Natural Gas c Propane Gas (LP) Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.