Page 1
8000/8100 Series Swing Door Operator Installation Instructions The manufacturer’s specifications for this product require the installation to be approved by an AAADM certified inspector. -USA 4324 Phil Hargett Court Toll Free: 800-438 1937 Monroe, NC USA 28110 704-289-9212 Http://www.record-usa.com Fax: 704-289-2024...
/ installation dealer must perform all measurements for forces, speeds, and times to insure proper and safe operation. record-usa is not responsible for improperly adjusted or maintained aut omatic doors or activation / safety systems and assumes no responsibility for damages caused by automatic door systems that have not been properly installed, tested, and adjusted.
OPERATOR HANDING IDENTIFICATION Product Description The record Series 8100 Swing Door Operator is a power-open, spring-close unit providing full functionality conforming to either ANSI 156.10 or ANSI A156.19 requirements. The self- monitoring microprocessor-based control maintains precise regulation throughout the door open / close cycle.
This unit is to be installed and commissioned by a trained technician with knowledge of ANSI A156.19 Standards for Power Operated Doors, applicable local codes, and record-USA installation recommendations. After installation, verify the door can be opened without power applied, and the force required to open the door does not exceed 50 pounds-force (222 N).
8000/8100 Series Swing Door Operator Installation Instructions Mechanical Installation The door panel must move freely throughout its entire opening and closing rotation. The door frame must provide a stable base, structurally sufficient to support automatic operation. Typi- cally the operator baseplate will overlap the door jambs by 1-1/2". Verify the installation conditions and select the arm configuration that most closely matches the installation.
8000/8100 Series Swing Door Operator Installation Instructions Shaft Stop Open Stop Fixed Stop The unit is provided with an adjustable full open stop. Rotate the door to the full open position; mount the Shaft Stop onto the upper output shaft and against the Fixed Stop.
8000/8100 Series Swing Door Operator Installation Instructions Exploded view of a typical single swing unit The Series 8000 Standard Rocker Switch Control Panel includes: 3 Position Rocker Switch - ON / OFF / OPEN Pushbutton - To reset the operator, press and hold 8 seconds LED (red) - Normally off;...
AUTOMATIC CAUTION DOOR ACTIVATE SWITCH TO OPERATE Full Power & Low Energy Daily Safety “Knowing Act” doors Check locate below control panel AUTOMATIC CAUTION DOOR AUTOMATIC CAUTION DOOR Full Power Swing ACTIVATE SWITCH TO OPERATE Side, 2-Way Traffic; Low Energy - Sensor Activation 58”...
Need help?
Do you have a question about the 8000 Series and is the answer not in the manual?
Questions and answers