Kenmore 33205 - Power Vent, 50 Gallon Owner's Manual page 31

Power vented gas models with hot surface ignition, for potable water heating only, not suitable for space heating, not for use in mobile homes, 40/50 gallon natural
Table of Contents

Advertisement

These guidelines
should beused b yaqualified service agent. Call Sears Service at1-800-4-MY-HOME
® (1-800-469-4663)
forassistance.
Inform t he associate
that this isa"Flammable
Vapor Ignition Resistant"
Product.
#
7
8
9
10
11
12
13
14
15
16
LED STATUS
VABC
@000@@
VABC
000000
VABC
000000
@000@
I
0 0000
00000
I ";°;I
000
PROBLEM
The gas control valve has detected
a problem
with the gas valve driver
circuit, internal
microprocessor,
or
other internal circuits.
The gas control valve has sensed
main burner flame out of proper
sequence.
The gas control valve has detected
excessive
water temperature
in the
tank and has activated
the ECO
(energy cut off) high temperature
limit.
The gas control valve has detected
that one or both of the temperature
adjust buttons are stuck.
The gas control valve has detected
the water temperature
sensor
(located in the control valve's
immersion
probe) is either open or
shorted.
The gas control valve has detected
the FV (flammable
vapor) sensor
is
either open or shorted.
The gas control valve has detected
the presence
of flammable
vapors
from the FV (flammable
vapor)
sensor.
The gas control valve has detected
the air pressure
switch circuit is
opening
repeatedly
during one
heating cycle.
LDO (Lint, Dust, and Oil) lockout
condition.
SOLUTION
Turn the power off for 10-20 seconds
then on again to
clear these error codes.
If any of these error codes persist or cannot be cleared
- replace the gas control valve.
1 Turn the power off for 10-20 seconds
then on again to
clear these error codes.
2 Replace the gas control valve if this error code persists.
1 Turn the power off for 10-20 seconds
then on again to
clear these error codes.
2 Replace the gas control valve if the error code persists.
1 Press and release both temperature
adjust buttons
several
times - cycle water heater power off and on.
2 Replace the gas control valve if the error code persists.
1 Turn the power off for 10-20 seconds
then on again to
clear these error codes.
2 Replace the gas control valve if the error code persists.
1 Ensure all FV sensor wiring is correct and the igniter
assembly
plug and socket connections
on the bottom
of the gas control valve are making
good contact.
2
1
Replace the FV sensor.
Do not touch any electrical
switch, do not use any
phone
in your building,
and do not try to light any
appliance.
Smell around the water heater to ensure there are no
gas leaks at the gas control valve, in the supply gas
line(s), or any other type of flammable
vapor(s)
in the
area.
Carefully
inspect the area surrounding
the water heater
for any substances
such as gasoline,
paint, paint
thinners,
varnish,
or cleaners
that could emit flammable
vapors.
Remove anything
that can potentially
emit
flammable
vapors from the area and store it properly
in
a different
location.
4 Call the technical
information
support
phone number
shown on the water heater labeling for further
assistance.
1 On models
equipped
with a dilution air intake screen on
the blower assembly
- check/clean
this screen.
2 On models
equipped
with a combustion
air intake
screen on the base ring (bottom) of the water heater -
check/clean
the screen.
3 Ensure intake air screen(s)
on models
so equipped
are
not obstructed.
31