Page 1
CLIPPER, CLIPPER CT, CLIPPER 5S, CLIPPER+, CLIPPER+ CT, CLIPPER+ 5S, CLIPPER UP , CLIPPER UP CT, CLIPPER UP 5S, CLIPPER J-COOK, CLIPPER J-COOK 5S, CLIPPER UP J-COOK, CLIPPER UP J-COOK 5S INSTALLATION, USE AND MAINTENANCE MANUAL To be kept by the purchaser...
Dear Customer, thank you for having chosen to heat and save with a Jolly Mec product. Please carefully read and keep this sheet before using the equipment. This sheet provides necessary information and suggestions on how to correctly install, use, clean and maintain the product.
CHAP.01 PREMISES 01.1 WARNINGS • Familiarity and compliance with the instructions given in this manual will ensure quick installation and correct use of the appliance. • Read the manual attentively before commencing installation, and be certain to follow the directions it contains, otherwise the war- ranty could be invalidated and the performance and safety of the appliance jeopardized.
This point is particularly important. An important point regarding behaviour for preventing injury and damage to DANGER: materials is expressed. 01.3 APPLIED STANDARDS All JOLLY MEC products are constructed according to the following directives: European construction products regulation. • EU 305/2011 Machines. •...
01.5 MANUFACTURER’S LIABILITY AND WARRANTY CONDITIONS Upon the delivery of this manual, Jolly Mec S.p.A. cannot be held liable, whether civil or criminal, for accidents due to partial or total non-compliance with the specifications herein contained. The manufacturer is especially held harmless from any liability in the following cases: •...
CHAP.02 ACCIDENT PREVENTION / SAFETY REGULATIONS 02.1 GENERAL CONSIDERATIONS • The manual refers to essential aspects of the directives, regulations and dispositions on using the machine, summarising its most significant points. • General legal regulations and mandatory rules regarding injury prevention and environmental protection must be observed.
• Keep the ventilation grids in the area the appliance is installed in clean conditions. • Do not burn any fuel except wood. • Check and periodically clean the fume exhaust pipe, from the appliance to the flue (Union). • It is strictly prohibited to start up the product with the combustion chamber door open or allow it to run with the glass broken.
RESIDUAL RISKS Though JOLLY MEC CAMINETTI S.p.A. does everything within its power to produce its systems with the greatest competence regarding safety and consulting all the directives, laws, and regulations available, there are still, if minor, some residual risks during the phases of: •...
CHAP.03 HANDLING AND TRANSPORT 03.1 RECEIVING GOODS The device is delivered on a pallet in a cardboard box and protected with shrink wrap cover sheet when receiving merchandise, check that: • all packaging is intact • all of the merchandise indicated on the delivery bill has actually been delivered •...
CHAP.04 ECOLOGICAL REGULATIONS 04.1 WASTE MATERIALS AND THEIR DISPOSAL Spare parts replaced during the machine’s product life are to be considered waste and must be taken to special collection centres or entrusted to authorised disposal centres. Ashes must be placed in a metal container with a sealed lid. The closed container must be placed on a non-combustible base and kept away from combustible materials until all the embers have been extinguished.
Page 11
END-OF-LIFE DISPOSAL OF THE EQUIPMENT COMPONENTS ( REGULATION (EU) 2015/1185 - Annex II - par. 3 - a) - 3) ) INSTRUCTIONS FOR CORRECT PRODUCT DISPOSAL The owner is fully and exclusively liable for stove demolition and disposal according to laws in force in his/her country regarding safety, respect and protection of the environment.
European Standard EN 13240. The CLIPPER, CLIPPER+, CLIPPER UP, CLIPPER CT, CLIPPER+ CT, CLIPPER UP CT, CLIPPER J-COOK, CLIPPER UP J-COOK, CLIPPER 5S, CLIPPER+ 5S, CLIPPER UP 5S, CLIPPER J-COOK 5S, CLIPPER UP J-COOK 5S stoves are high- CLIPPER CLIPPER+ performance products optimised for new installations.
05.2 PRODUCT IDENTIFICATION It is COMPULSORY to indicate the product MODEL, the LOT number and SERIAL NUMBER in all communications with the Manufacturer. Identification numbers are printed on the adhesive plate located on the back of the appliance as illustrated. Appliance performance values measured during inspection tests according to the indicated reference and EC markings are also included on the plate.
06.1 HOMOLOGATION Technical specifications resulting from laboratory tests conducted according to EN 13240 test methods at the CERTIFICATION institute. Description CLIPPER CLIPPER+ CLIPPER UP Nominal burning output Nominal heat output Nominal heating power released into the environment 1,83 1,83 1,83...
Page 15
All appliance tests, final inspection and fine-tuning was performed using the recommended fuels. Jolly Mec Caminetti S.p.A. is not responsible for malfunctions, breakdowns or problems due to the use of wood logs that are not recommended, as combustion parameters vary according to the quality of the fuel.
06.2 RECOMMENDED FUELS WARNING WOOD QUALITY IS VERY IMPORTANT; PLEASE READ THIS SECTION CAREFULLY. The characteristics of fuel wood for stoves and fireplaces are defined by quality classes A1 and A2 set forth by UNI EN ISO 17225-5 standard. WOOD COMBUSTION Wood clean burning is a process that reflects the natural decomposition itself;...
The appliance comes on a pallet covered by a cardboard box and with the following additional components: • Installation, use and maintenance manual • Heat proof glove 1. Combustion chamber door CLIPPER CT 2. Handle for opening the door CLIPPER 5S 3. Comburent air regulation lever 4. Openable lower door 5. Ash drawer 6.
CHAP.07 POSITIONING AND CONNECTIONS FOR THE INSTALLER WARNING The device must be installed and used in accordance with all local and national laws and EC Regulations. The installer is directly liable for all electrical system parts, generation hook-up to the system, ventilation and the fume exhaust system.
For appliances where exhausts that are not coaxial to the flue gas outlet must be reached, changes in direction must be achieved by using 45° open elbows or an elbow with a direction no greater than 90° to the vertical (Fig. 1). The use of counter slope elements is forbidden.The flue union must have a constant section and allow soot to be collected and swept away.
All models have a standard cast-iron smoke exhaust collar fitted (Fig. 2-3) THE COLLAR IS ONLY TO BE USED WHEN ANTI-CONDENSATION FITTINGS ARE USED (TO BE PURCHASED BY THE INSTALLER) ONLY FOR CLIPPER, CLIPPER UP AND CLIPPER+ MODELS (FOR THE LATTER MODEL ONLY FOR THE UPPER OUTLET). Fig. 2...
Page 22
- upper (with anti-condensation fitting); - upper (without anti-condensation fitting). a1) CLIPPER, CLIPPER UP upper flue outlet - (with anti-condensation fitting) • Position the anti-condensation fitting (to be purchased by the installer) on the flue outlet collar of the stove (Fig. 1-2-3);...
Page 23
CLIPPER, CLIPPER UP upper flue outlet - (without anti-condensation fitting) • Remove the standard collar as described in step 4. • Position the chimney flue (see CHAP.. 07.1) by inserting it inside the flue outlet of the stove (Fig. 1-2-3).
Page 24
CLIPPER+ flue outlet - (without anti-condensation fitting) • Remove the standard collar as described in step 4. • Position the chimney flue (see CHAP.. 07.1) by inserting it inside the flue outlet of the stove (Fig. 1-2-3). Fig. 1 Fig. 2 Fig. 3...
Page 25
5S, CLIPPER UP 5S MODEL outlet collar must be removed. Flue outlet options: - upper c1) CLIPPER CT, CLIPPER UP CT, CLIPPER 5S, CLIPPER UP 5S flue outlet • Remove the standard collar as described in step 4. • Position the pipe with turbulator by inserting it inside the flue outlet of the stove (Fig. 1-2-3).
Page 26
(Fig. 4-5). Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 e) CLIPPER J-COOK, CLIPPER UP J-COOK, CLIPPER J-COOK 5S, CLIPPER UP J-COOK 5S MODELS Possibilità di uscita fumi: - superiore e1) CLIPPER J-COOK, CLIPPER UP J-COOK flue outlet - (with anti-condensation fitting) • Position the anti-condensation fitting (purchased by the installer) on the oven smoke outlet collar (Fig. 1-2-3);...
In Fig. 1 are shown the safety distances from surrounding flammable materials applicable to all installation types available: Flammable Wall CLIPPER, CLIPPER+, CLIPPER UP, CLIPPER CT, CLIPPER+ CT, CLIPPER UP CT, CLIPPER UP J-COOK, CLIPPER J-COOK A Straight Distance from flammable side...
Page 28
La JOLLY-MEC caminetti S.p.A. si riserva a termini di legge la proprietà del presente disegno con divieto di riprodurlo o comunicarlo a terzi senza sua autorizzazione L L E n 80 n 518 n 518 n 518 CLIPPER UP CLIPPER UP CT CLIPPER UP 5S n 150 n 150 n 150 Descrizione Anagrafica articolo...
Page 29
- (Main quotes for carrying out installation) - measurements in mm n 80 n 80 n 80 n 518 n 518 n 518 CLIPPER UP J-COOK CLIPPER J-COOK CLIPPER UP J-COOK 5S CLIPPER J-COOK 5S n 150 n 150 n 150 Descrizione Anagrafica articolo Descrizione Anagrafica articolo A A S S S S .
Wood quantity Dimension record time (Fig. 6) 2 dentical logs for a total of Lenght: 24 cm 47 minutes CLIPPER 5S Position 3 (Fig. 3a) CLIPPER+ 5S 1,36 kg Side: 11x3 cm CLIPPER UP 5S CLIPPER J-COOK 5S CLIPPER UP J-COOK 5S...
WARNING The hearth must always be closed, except when the wood is added, to avoid the leakage of smoke. Always open and close the door gently, and make sure the handle is locked firmly in place. To prevent damage to the Fireflector (not included in the warranty) always avoid overloading the fireplace or throwing pieces of wood into the combustion chamber.
Time between one cleaning and the next is strictly tied to fuel quality. The most suitable cleaning frequency can only be established a few days after use according to the actual amount of deposited residue and may vary from recommended Jolly Mec intervals.
08.4 EXTRAORDINARY MAINTENANCE We wish to remind you that the Extraordinary Maintenance to be carried out on this type of product must be done obligatorily every year by qualified maintenance personnel, in order to maintain its functionality, efficiency and comfort. For any further queries you may have, we invite you to contact the specialised Technical Service Center through your retailer.
10.1 COMMISSION REGULATION (EU) 2015/1185 Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER Indirect heating functionality Direct heat output Indirect heat output Reference standard...
Page 35
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 36
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER+ Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 37
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 38
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER CT Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 39
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 40
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER+ CT Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 41
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 42
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER UP Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 43
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 44
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER UP CT Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 45
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 46
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER J-COOK Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 47
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 48
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER UP J-COOK Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 49
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 50
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER 5S Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 51
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 52
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER UP 5S Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 53
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 54
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER+ 5S Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 55
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 56
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER J-COOK 5S Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 57
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 58
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) CLIPPER UP J-COOK 5S Indirect heating functionality Direct heat output Indirect heat output Reference standard EN13240 Notified Body ACTECO s.r.l - NB 1880 - Via Amman, 41, 33084,...
Page 59
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Need help?
Do you have a question about the CLIPPER and is the answer not in the manual?
Questions and answers