Summary of Contents for Jolly Mec UNIVERSALJOLLY EVO 62 QUICK
Page 1
UNIVERSALJOLLY EVO 62 QUICK UNIVERSALJOLLY EVO 68 QUICK UNIVERSALJOLLY EVO 80 QUICK UNIVERSALJOLLY EVO 90 QUICK UNIVERSALJOLLY EVO 62 QUICK CT UNIVERSALJOLLY EVO 62 QUICK CT UNIVERSALJOLLY EVO 80 QUICK CT UNIVERSALJOLLY EVO 90 QUICK CT I N S T A L L A T I O N ,...
Page 2
Dear Customer, thank you for having chosen to heat and save with a Jolly Mec product. Please carefully read and keep this sheet before using the equipment. This sheet provides necessary information and suggestions on how to correctly install, use, clean and maintain the product.
CHAP.01 PREMISES 01.1 WARNINGS • Familiarity and compliance with the instructions given in this manual will ensure quick installation and correct use of the appliance. • Read the manual attentively before commencing installation, and be certain to follow the directions it contains, otherwise the war- ranty could be invalidated and the performance and safety of the appliance jeopardized. • The installation manual is an integral part of the product and must be given to the user. • It must be kept in a safe place and consulted carefully, as all of the warnings provide important information on safety during instal- lation, use and maintenance. • Incorrect installation of the appliance could cause damage and injury to people or animals, for which the manufacture cannot not be held liable. • Installation shall be performed by qualified operators in accordance with the regulations in force in the Country of installation. • The manufacturer declines any contractual or non-contractual liability for damages caused by errors in installation or use of the appliance or failure to follow the instructions contained in this manual. • All rights on the reproduction of this technical manual are owned by Jolly Mec Caminetti S.p.A. The descriptions and illustrations provided in the following publication are not binding. • reserves the right to make any modifications that may be deemed appropriate. • Jolly Mec Caminetti S.p.A This manual cannot be given to third parties for perusal without the written permission of • Jolly Mec Caminetti S.p.A • The technical directions for installation contained in this manual should be considered as basic requirements. Regulations in some countries may be more restrictive; in this instance, comply fully with the regulations prevailing in the country of installation (all laws and local bylaws must be observed when installing and using the appliance, including those referring to national and European standards).
This point is particularly important. An important point regarding behaviour for preventing injury and damage to DANGER: materials is expressed. 01.3 APPLIED STANDARDS All JOLLY MEC products are constructed according to the following directives: • EU 305/2011 European construction products regulation. Machines. •...
01.5 MANUFACTURER’S LIABILITY AND WARRANTY CONDITIONS Upon the delivery of this manual, Jolly Mec S.p.A. cannot be held liable, whether civil or criminal, for accidents due to partial or total non-compliance with the specifications herein contained. The manufacturer is especially held harmless from any liability in the following cases: •...
CHAP.02 ACCIDENT PREVENTION / SAFETY REGULATIONS 02.1 GENERAL CONSIDERATIONS • The manual refers to essential aspects of the directives, regulations and dispositions on using the machine, summarising its most significant points. • General legal regulations and mandatory rules regarding injury prevention and environmental protection must be observed.
• In alarm status for failed start up, do not try to restart the appliance until the firebox has been thoroughly cleaned. • Keep the ventilation grids in the area the appliance is installed in clean conditions. • Do not use fuels that are not recommended. •...
RESIDUAL RISKS Though JOLLY MEC CAMINETTI S.p.A. does everything within its power to produce its systems with the greatest competence regarding safety and consulting all the directives, laws, and regulations available, there are still, if minor, some residual risks during the phases of: •...
CHAP.03 HANDLING AND TRANSPORT 03.1 RECEIVING GOODS The device is delivered on a pallet in a cardboard box and protected with shrink wrap cover sheet when receiving merchandise, check that: • all packaging is intact • all of the merchandise indicated on the delivery bill has actually been delivered •...
CHAP.04 ECOLOGICAL REGULATIONS 04.1 WASTE MATERIALS AND THEIR DISPOSAL Spare parts replaced during the machine’s product life are to be considered waste and must be taken to special collection centres or entrusted to authorised disposal centres. Ashes must be placed in a metal container with a sealed lid. The closed container must be placed on a non-combustible base and kept away from combustible materials until all the embers have been extinguished.
Page 12
END-OF-LIFE DISPOSAL OF THE EQUIPMENT COMPONENTS ( REGULATION (EU) 2015/1185 - Annex II - par. 3 - a) - 3) ) INSTRUCTIONS FOR CORRECT PRODUCT DISPOSAL The owner is fully and exclusively liable for stove demolition and disposal according to laws in force in his/her country regarding safety, respect and protection of the environment. At the end of its useful life, the product must not be disposed of together with urban waste. It can be delivered to the appropriate differentiated collection centres set up by the municipal administrations, or to retailers that provide this service.
UNIVERSALJOLLY EVO 62 QUICK, UNIVERSALJOLLY EVO 68 QUICK UNIVERSALJOLLY EVO 80 QUICK, UNIVERSALJOLLY EVO 90 QUICK, UNIVERSALJOLLY EVO 62 QUICK CT, UNIVERSALJOLLY EVO 68 QUICKCT, UNIVERSALJOLLY EVO 80 QUICK CT, UNIVERSALJOLLY EVO 90 QUICK CT fireplaces are wood-fired with intermittent loading and approved according to European standard EN13229.
05.2 PRODUCT IDENTIFICATION It is COMPULSORY to indicate the product MODEL, the LOT number and SERIAL NUMBER in all communications with the Manufacturer. Identification numbers are printed on the adhesive plate located on the back of the appliance as illustrated. Appliance performance values measured during inspection tests according to the indicated reference and EC markings are also included on the plate.
All appliance tests, final inspection and fine-tuning was performed using the recommended fuels. Jolly Mec Caminetti S.p.A. is not responsible for malfunctions, breakdowns or problems due to the use of wood logs that are not recommended, as combustion parameters vary according to the quality of the fuel.
06.2 RECOMMENDED FUELS WARNING WOOD QUALITY IS VERY IMPORTANT; PLEASE READ THIS SECTION CAREFULLY. The characteristics of fuel wood for stoves and fireplaces are defined by quality classes A1 and A2 set forth by UNI EN ISO 17225-5 standard. WOOD COMBUSTION Wood clean burning is a process that reflects the natural decomposition itself;...
06.3 COMPONENTS The equipment is supplied on a pallet, in a cardboard box covered with heat shrink film and with the following additional components: • Installation, use and maintenance manual UniversalJolly EVO QUICK Fireplace pipe/collar Ventilation kit (Optional) Heat proof glove Legs (Optional) Combustion air pipe coupling for rear air intake (in alternative to 7 - optional) Combustion air pipe coupling for lower air intake (in alternative to 6 - optional) Damper for hot air regulation (Optional)
Model UNIVERSALJOLLY EVO 62 QUICK UNIVERSALJOLLY EVO 68 QUICK UNIVERSALJOLLY EVO 80 QUICK UNIVERSALJOLLY EVO 90 QUICK Model UNIVERSALJOLLY EVO 62 QUICK CT 1418 UNIVERSALJOLLY EVO 68 QUICK CT 1486 UNIVERSALJOLLY EVO 80 QUICK CT 1511 UNIVERSALJOLLY EVO 90 QUICK CT...
CHAP.07 POSITIONING AND CONNECTIONS FOR THE INSTALLER 07.1 FLUE OR FUME EXHAUST SYSTEM The flue or fume exhaust system is a fundamental element for the proper functioning of the stove and must comply with the following general standards: EN1856-1 Chimneys. Requirements for metal chimneys - Part 1: System chimney products EN1856-2 Chimneys.
The use of counter slope elements is forbidden.The flue union must have a constant section and allow soot to be collected and swept away. Changes in cross-section are only allowed at the outlet of the heat generator: the use of adaptors on the coupling with the chimney flue is prohibited.
07.3 ASSEMBLY SEQUENCE Install the fireplace as follows: The insert can be installed on an existing fireplace or built ex novo with a suitable casing. A) INSTALLATION IN A PRE-EXISTING FIREPLACE Prepare the air intakes as indicated below according to the type of chosen combustion air intake. 1a) Combustion air intake from inside the installation room.
Page 22
Repeat the same procedure for the opposite side of the fireplace . 9-10-11-12). . 10 . 11 . 12 b4) Prepare the opening communicating directly with the external environment (minimum Ø100 mm for 90, 80 and 68 models - minimum Ø80 mm for 62 model) to be able to connect the pipe (minimum Ø100 mm for 90, 80 and 68 models - minimum Ø80 mm for 62 model) on one side to the collar (X) and on the other to the air intake directly communicating with the outside.
Page 23
c3) Unscrew screws L, M. Remove the plate (Y). Loosen screw N. Move the plate (Z) towards the bottom of the fireplace. Reposition the plate (Y) and tighten screws L, M, N . 7-8-9-10). . 10 Repeat the same procedure for the opposite side of the fireplace .
Page 24
For Universaljolly EVO 62 QUICK, Universaljolly EVO 68 QUICK, Universaljolly EVO 80 QUICK, Universaljolly EVO 90 QUICK models follow points number 4, 6, 7. For Universaljolly EVO 62 QUICK CT, Universaljolly EVO 68 QUICK CT, Universaljolly EVO 80 QUICK CT , Universaljolly EVO 90 QUICK CT models follow points number 5, 6, 7.
Page 25
Remove the fireplace deflector (A) - see chapter 08.5 . 1-2). Insert the fireplace into the pre-existing fireplace. To prevent heat loss, it is recommended to insulate the fireplace before fitting in place using the insulating material supplied. Position the collar on the fireplace, pulling down on bar C .
Page 26
B) INSTALLATION IN A NEW FIREPLACE Assemble the legs on the fireplace. Remove the deflector (X) - see chapter 08.5 . 1-2). Lay the fireplace with the back on the ground . 3). Position the legs (Y) and tighten screws A, B, C, D, E, F .
Page 27
Prepare the air intakes as indicated below according to the type of chosen combustion air intake. 2a) Combustion air intake from inside the installation room. Inside the installation room, provide an opening communicating with the external environment of at least 450 cm 2b) Combustion air intake from the rear of the fireplace and directly from the external environment by means of a duct with a minimum Ø100 mm (90, 80 and 68 model) at minimum Ø 80 mm (62 model). Complete the steps below: b1) Remove the precut closing plug (W) .
Page 28
Repeat the same procedure for the opposite side of the fireplace . 9-10-11-12). . 10 . 11 . 12 b4) Prepare the opening communicating directly with the external environment (minimum Ø100 mm for 90, 80 and 68 models - minimum Ø80 mm for 62 model) to be able to connect the pipe (minimum Ø100 mm for 90, 80 and 68 models - minimum Ø80 mm for 62 model) on one side to the collar (X) and on the other to the air intake directly communicating with the outside.
Page 29
For Universaljolly EVO 62 QUICK, Universaljolly EVO 68 QUICK, Universaljolly EVO 80 QUICK models follow points number 4, 6, 7. For Universaljolly EVO 62 QUICK CT, Universaljolly EVO 68 QUICK CT, Universaljolly EVO 80 QUICK CT models follow points number 5, 6, 7.
Page 30
For 62 QUICK, 68 QUICK, 80 QUICK, 90 QUICK models Unscrew collar screws A, B . 1). Remove collar bar C . 2-3). Position the collar on the fireplace and secure it with screws A, B . 4-5). Reposition the fireplace deflector . 6). For 62 QUICK CT, 68 QUICK CT, 80 QUICK CT, 90 QUICK CT models Couple the two parts of the fume outlet pipe (a.b) using the clip supplied (c), inserting the part with the turbulator coupling pin (a) inside the part without the pin (b).
Page 31
Position the chimney flue. Create suitable openings in the casing for hot air release and circulation (minimum 400 cm MINIMUM CONVECTOR AIR INLET AND OUTLET SECTIONS . 1 shows the minimum convector air inlet and outlet sections valid for all types of proposed installations: A Minimum convector air inlet section: minimum 400 cm B Minimum convector air outlet section:...
07.4 INSTALLING THE CLADDING: PRECAUTIONS • Protection of domestic walls Installation of the fireplace near inflammable walls is only allowed if you maintain the distances indicated below, or if suitable protection is interposed. The surfaces such as the flooring, ceiling and walls of the home in the vicinity of the fireplace must be protected to prevent overheating.
07.5 EXAMPLE OF AIR DUCTING TO OTHER ROOMS When installing the optional ventilation kit, hot air can be ducted by installing the pipes in the rooms to be heated. The return of air in the fireplace room must be guaranteed from every room in which the hot air arrives, through openings under the doors or vents (see F .
Dimension record time 2 dentical logs for a total of Lenght: 35 cm . 6) 49 minutes Universaljolly EVO 62 QUICK CT Position 3 ( . 3) 1,96 kg Side: 8x8 cm . 6) Universaljolly EVO 68 QUICK CT 2 dentical logs for a total of...
Page 35
When starting the fireplace again in the future, follow the same procedure illustrated above, cleaning the fireplace beforehand removing excessive ashes from the fire base (bearing in mind that the presence of a layer of ashes on the same makes starting the fire easier).
08.2 TIPS FOR THE USER • When the heating system is ducted, it is mandatory to leave at least one vent open to discharge the heat generated when the device is on. • The glass door must remain closed during wood combustion; it can only be opened to add more wood. •...
Time between one cleaning and the next is strictly tied to fuel quality. The most suitable cleaning frequency can only be established a few days after use according to the actual amount of deposited residue and may vary from recommended Jolly Mec intervals. WARNING...
08.4 EXTRAORDINARY MAINTENANCE We wish to remind you that the Extraordinary Maintenance to be carried out on this type of product must be done obligatorily every year by qualified maintenance personnel, in order to maintain its functionality, efficiency and comfort. For any further queries you may have, we invite you to contact the specialised Technical Service Center through your retailer.
CHAP.09 FAULT DIAGNOSIS AND TROUBLESHOOTING 09.1 PROBLEMS WARNING In accordance with the laws in force on safety for electrical appliances, a specialised Technical Service Center or qualified personnel must obligatorily be contacted for all installation, maintenance or interventions that require access to electrical parts.
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Universaljolly EVO 62 QUICK Indirect heating functionality Direct heat output Indirect heat output Reference standard EN 13229 Notified Body TÜV Rheinland Energy GmBH - NB 2456 - Am Grauen...
Page 41
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 42
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Universaljolly EVO 68 QUICK Indirect heating functionality Direct heat output Indirect heat output Reference standard EN 13229 Notified Body TÜV Rheinland Energy GmBH - NB 2456 - Am Grauen...
Page 43
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 44
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Universaljolly EVO 80 QUICK Indirect heating functionality Direct heat output 11,0 Indirect heat output Reference standard EN 13229 Notified Body TÜV Rheinland Energy GmBH - NB 2456 - Am Grauen...
Page 45
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 46
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Universaljolly EVO 90 QUICK Indirect heating functionality Direct heat output 10,6 Indirect heat output Reference standard EN 13229 Notified Body TÜV Rheinland Energy GmBH - NB 2456 - Am Grauen...
Page 47
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 48
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Universaljolly EVO 62 QUICK CT Indirect heating functionality Direct heat output Indirect heat output Reference standard EN 13229 Notified Body TÜV Rheinland Energy GmBH - NB 2456 - Am Grauen...
Page 49
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 50
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Universaljolly EVO 68 QUICK CT Indirect heating functionality Direct heat output 10,9 Indirect heat output Reference standard...
Page 51
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 52
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Universaljolly EVO 80 QUICK CT Indirect heating functionality Direct heat output 12,0 Indirect heat output Reference standard...
Page 53
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Page 54
Information requirements for solid fuel local space heaters ACCORDING TO COMMISSION REGULATION (EU) 2015/1185 Manufacturer JOLLY-MEC CAMINETTI SPA Trademark JOLLY MEC Model identifier(s) Universaljolly EVO 90 QUICK CT Indirect heating functionality Direct heat output 11,0 Indirect heat output Reference standard...
Page 55
Type of heat output/room temperature Auxiliary electricity consumption control (select one) Item Symbol Value Unit Item Value 0,000 Single stage heat output, no room At nominal heat output temperature control 0,000 Two or more manual stages, no At minimum heat room temperature control output 0,000...
Need help?
Do you have a question about the UNIVERSALJOLLY EVO 62 QUICK and is the answer not in the manual?
Questions and answers