  • Page 1 Manual HL318PLUS SSC LCD MANUAL_WB_EPWN_ENG_V1.04...
  • Page 2: Table Of Contents

    CONTENTS 1.0 INTRODUCTION ......................3 ....................3 TECHNICAL PARAMETERS ......................3 MAIN FUNCTIONS ........................4 DIMENSION ..........................4 MODEL 2.0 INTERFACE ........................4 ........................ 4 POWER SUPPLY 2.2 RS232 ..........................4 ........................4 LOA D CELL 3.0 OPERATION ........................4 ......................
  • Page 3: Introduction

    1.0 INTRODUCTION 1.1 Technical parameters ● 6-digit 1.6-inch LCD, various indicating lamps, long service life and good shock resistance ● 7 buttons, simple operation ● Protection level: IP5x ● Excitation voltage: +5VDC ● Load capacity of sensor: at most four 350Ω simulation sensors ●...
  • Page 4: Dimension

    1.3 Dimension 1.4 Model HL318 Plus SSC 2.0 Interface 2.1 Power supply 1Pin(inner core): DC+ 2Pin(outer core): 2.2 RS232 1Pin: TXD(红) 2Pin: RXD(绿) 3Pin: GND (黑) 2.3 Load cell 1Pin: +V (红) 2Pin: +SN (蓝) 3Pin: +S (绿) 4Pin: 屏蔽(黑) 5Pin: -S(白) 6Pin: -V(黑)...
  • Page 5: Buttions

    ±d/4 the lamp is on; otherwise, the lamp is off. The lamp is on at net weight and off at Gross/net weight gross weight. Weight unit The lamp indicates the weight unit in use. When the totalizaton function is in use the Total Totalization lamp is on.
  • Page 6: Setting

    4.0 Setting 4.1 Setting Entry Normally press 〖CAL〗 until 【 】 shows. Press 〖ON/OFF〗 to enter into the menu setting interface to set parameters from F1~F5. Normally, press 〖 GROSS〗 until 】 shows. Press 〖ON/OFF〗 to enter into the menu setting interface to set 【...
  • Page 7: F2 Applicable Parameter Setting

    and zero calibration ends. F1.5 Load Calibration 】add weights 【 Add weights to scale and make sure: full capacity *50% ≤ weights ≤ full capacity. Press 『ON/OFF』 . 【 】 Enter the same value as the weights. Wait until the scale is stable and press 『ON/OFF』.
  • Page 8: F4 Serial Communication

    2-----day.month.year F 3.2 Date setting (see F 3.1) F 3.3 Time setting (format: hour.minute.second) F 3.4 Overtime backlight shutdown time setting Selectable parameters: 0~999 second (default: 0) If 0 is set, this function is shutdown. F 3.6 Auto power-off time setting Selectable parameters: 0~60min (default: 0) If 0 is set, this function is shutdown.
  • Page 9: Functions

    F 5.3 Inner code The indicator shows the after-filtering inner code. Press 〖COUNT〗or〖ON/OFF〗to exit. 5.0 Functions 5.1 Totalization F 1.10=0 Operation: Normally add weights to scale and press 〖TOTAL〗. The screen shows “Add-” and returns to the main weighing interface. Remember to zero the scale before putting things on scale every time;...
  • Page 10: Appendixⅱ Serial Output Format

    】 Invalid 【 Press 〖ON/OFF〗to restore and then restart. If the code shows again, return the indicator to factory; 】 EEPROM verification and error if there’s no code re-calibrate the 【 indicator. Note: Restoring factory default includes restoring all parameters. The scale is dynamic during Check the scale 【...
  • Page 11: Appendixⅲ Printing Output Format

    0 0 0 k g Example 2: unstable, net weight: -0.200kg, sp = space. U S , N T , 2 0 0 k g AppendixⅢ Printing Output Format LIST LIST Date 2018/04/14 Date 2018/04/14 Time 15:08:46 Time 15:10:18 ----------------------- ----------------------- Gross 2.061kg Count...